{"product_id":"80026-044-06-allen-bradley-switching-power-supply-powerflex","title":"80026-044-06 Allen-Bradley Switching Power Supply PowerFlex","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 80026-044-06\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e80026-044-06\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSwitching Power Supply, operates as a dedicated hardware component for power regulation and distribution within PowerFlex medium-voltage AC drive systems.\u003c\/p\u003e\n\u003ch3\u003eModel Identification and Version Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 80026-044-06 module is an engineering-specific power unit designed for high-voltage isolation environments. The suffix \"-R\" denotes a RoHS-compliant iteration of the base model. Both variants maintain functional parity regarding electrical output, though minor mechanical dimensions or weights may fluctuate due to updated material composition in compliance with environmental regulatory standards.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e80026-044-06\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30.4 x 29.8 x 7.4 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e144 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 - 240 VAC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC +\/- 1 %\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 A (Continuous)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Integration\u003c\/h3\u003e\n\u003cp\u003eThe unit utilizes internal circuitry to manage backplane bus communication velocity and power monitoring, ensuring seamless integration with the host drive controller. Firmware flash compatibility is managed via the drive-level control interface, allowing for system-wide diagnostic monitoring of the power supply status. Deterministic network connectivity relies on the stable output provided by this module, which ensures that control signals remain free of noise even when the system I\/O density is scaled to maximum capacity within the drive chassis.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 80026-044-06 power supply unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical safety and compliance documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Accessories, mounting cables, and external fuses are not included with the standard module shipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Utilize the surface-mount configuration; ensure the mounting surface is thermally conductive to assist with internal heat dissipation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the module chassis to the drive cabinet ground reference using a high-frequency braided conductor to maintain the 3000 VDC isolation integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Management: Ensure operating environment temperature remains within the specified range, maintaining a minimum of 5 cm clearance around ventilation intake\/exhaust ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration\/Shock: Secure all fasteners with thread-locking compounds to withstand the rated 5 g shock and vibration environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Use factory-specified shielded cabling for all output channels to minimize EMI\/RFI impact on the control network.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the significance of the 3000 VDC isolation rating?\u003c\/p\u003e\n\u003cp\u003eThe 3000 VDC rating provides electrical separation between the primary high-voltage AC input and the low-voltage secondary outputs, protecting control logic from surges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this power supply support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eNo. The module must be installed or removed only when the input AC power is disconnected and the internal capacitors are fully discharged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat triggers the internal thermal protection?\u003c\/p\u003e\n\u003cp\u003eThermal protection activates if the internal junction temperatures exceed design limits due to inadequate cooling or sustained over-current conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the short-circuit protection implemented?\u003c\/p\u003e\n\u003cp\u003eThe unit utilizes current-limiting circuitry, typically specified to clamp at 20 A, to prevent damage during output-side faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the six secondary outputs be connected in parallel?\u003c\/p\u003e\n\u003cp\u003eNo. Each secondary output is designed for isolated service; paralleling them will compromise electrical isolation and likely trigger protection circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the efficiency rated at \u0026gt; 88%?\u003c\/p\u003e\n\u003cp\u003eHigh efficiency is achieved via advanced switching topologies designed to minimize thermal losses during power conversion in high-voltage drive applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 80026-044-06-R fully interchangeable with the original?\u003c\/p\u003e\n\u003cp\u003eYes, the -R version is electrically and physically compatible with original installations, incorporating updated materials for RoHS compliance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I verify the module status via the drive controller?\u003c\/p\u003e\n\u003cp\u003eThe drive monitor software tracks voltage sag and output status; verify the module diagnostic codes in the drive's technical reference manual.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066475073709,"sku":"80026-044-06","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/80026-044-06.jpg?v=1781602441","url":"https:\/\/www.maxwellplc.com\/ru\/products\/80026-044-06-allen-bradley-switching-power-supply-powerflex","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}