{"product_id":"60r-inp01-02-0-bently-nevada-pav-prox-accel-vel-module-orbit-60-series","title":"60R\/INP01-02-0 Bently Nevada PAV Prox Accel Vel Module ORBIT 60 Series","description":"\u003cp\u003eConfigured for dynamic sensor signal digitization in the Bently Nevada ORBIT 60 Series platform, the \u003cstrong\u003eBently Nevada 60R\/INP01-02-0\u003c\/strong\u003e (\u003cstrong\u003e60R\/INP01-02-0\u003c\/strong\u003e PAV Prox Accel Vel Module) provides direct acquisition of proximity, acceleration, and velocity measurement signals.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Details\u003c\/h3\u003e\n\u003cp\u003eThe 60R\/INP01-02-0 is an ORBIT 60 Series Dynamic Input Module configured for Prox\/Accel\/Vel signal measurement. The module supports four-channel dynamic inputs and provides sensor power, signal digitization, and high-speed data processing functions.\u003c\/p\u003e\n\u003cp\u003eThe configuration includes Multi hazardous area certification support (CSA, ATEX, IECEx), no SIL rating, and compatibility with proximity, acceleration, and velocity transducers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e60R\/INP01-02-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePAV (Prox\/Accel\/Vel) Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eORBIT 60 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Input Channels\u003c\/td\u003e\n\u003ctd\u003e4-channel dynamic input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Inputs\u003c\/td\u003e\n\u003ctd\u003eProx, Accel, Velom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProx\/Accel Input Range\u003c\/td\u003e\n\u003ctd\u003e0-40 kHz, 1% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVelom Input Range\u003c\/td\u003e\n\u003ctd\u003e5 Hz - 20 kHz, 2% of Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003e102.4 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Range\u003c\/td\u003e\n\u003ctd\u003e1 - 12,000 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Certifications\u003c\/td\u003e\n\u003ctd\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSIL Level\u003c\/td\u003e\n\u003ctd\u003eNo SIL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Consumption\u003c\/td\u003e\n\u003ctd\u003e11 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTypical Power Consumption\u003c\/td\u003e\n\u003ctd\u003e7.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e22.2 x 15.7 x 7 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in available documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum 11 W, typical 7.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDynamic Signal Processing and Rotor Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe 60R\/INP01-02-0 digitizes dynamic sensor signals at a 102.4 kHz sampling rate to capture vibration waveform content from connected transducers. The module provides sensor power for supported measurement devices and transfers processed data through the ORBIT 60 system architecture.\u003c\/p\u003e\n\u003cp\u003eThe module supports eddy-current proximity measurement interfaces where probe scaling and gap voltage validation are required for accurate shaft displacement monitoring. Correct sensor configuration ensures appropriate signal amplitude interpretation and measurement accuracy.\u003c\/p\u003e\n\u003ch3\u003eSpeed Reference and Signal Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe ORBIT 60 Dynamic Input Module supports speed and Keyphasor signal configurations for synchronous machinery measurements. Primary and backup speed source functions can be configured for applications requiring speed reference continuity.\u003c\/p\u003e\n\u003cp\u003eWhen backup speed operation is enabled, the module can transition measurement reference functions from a primary speed input to a backup channel. Phase timing compensation can be configured to maintain measurement alignment during speed source changes.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 60R\/INP01-02-0 PAV Prox Accel Vel Module\u003c\/li\u003e\n\u003cli\u003e1 x ORBIT 60 Series Dynamic Input Module assembly\u003c\/li\u003e\n\u003cli\u003e1 x Standard module hardware configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eModule Installation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module according to ORBIT 60 rack and system configuration requirements.\u003c\/li\u003e\n\u003cli\u003eVerify hazardous area certification requirements before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm connected transducer types match the configured input channels.\u003c\/li\u003e\n\u003cli\u003eCheck module power requirements before system startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSensor Wiring\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eUse appropriate shielded cables for dynamic vibration signal connections.\u003c\/li\u003e\n\u003cli\u003eRoute sensor wiring away from high-current power cables.\u003c\/li\u003e\n\u003cli\u003eVerify connector seating before commissioning.\u003c\/li\u003e\n\u003cli\u003eMaintain correct grounding practices for vibration monitoring circuits.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat signals can the 60R\/INP01-02-0 measure?\u003c\/p\u003e\n\u003cp\u003eThe module supports proximity, acceleration, and velocity dynamic input signals through ORBIT 60 Series monitoring systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many input channels are provided?\u003c\/p\u003e\n\u003cp\u003eThe Dynamic Input Module provides four dynamic input channels for connected machinery monitoring sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the sampling rate of this module?\u003c\/p\u003e\n\u003cp\u003eThe module digitizes dynamic input signals at a sampling rate of 102.4 kHz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module support Keyphasor signals?\u003c\/p\u003e\n\u003cp\u003eYes. The module can be configured for speed and Keyphasor signal applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat hazardous area certifications are available?\u003c\/p\u003e\n\u003cp\u003eThis configuration supports CSA, ATEX, and IECEx hazardous area certification options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module provide SIL certification?\u003c\/p\u003e\n\u003cp\u003eThe specified 60R\/INP01-02-0 configuration does not include a SIL rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of backup speed source support?\u003c\/p\u003e\n\u003cp\u003eBackup speed source support provides an alternate speed reference for synchronous measurements if the primary source becomes invalid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat installation practice is recommended for dynamic input wiring?\u003c\/p\u003e\n\u003cp\u003eShielded wiring, proper grounding, and separation from interference sources should be maintained for signal quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025526706349,"sku":"60R\/INP01-02-0","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/60RINP01-02-0_25.jpg?v=1785740744","url":"https:\/\/www.maxwellplc.com\/ru\/products\/60r-inp01-02-0-bently-nevada-pav-prox-accel-vel-module-orbit-60-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}