{"product_id":"5069-l306erm-allen-bradley-programmable-automation-controller-compactlogix-5380","title":"5069-L306ERM Allen-Bradley Programmable Automation Controller CompactLogix 5380","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 5069-L306ERM\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e5069-L30\u003c\/strong\u003e Programmable Automation Controller, operates as a dedicated hardware component for integrated motion control and real-time I\/O execution within EtherNet\/IP networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature \u0026amp; Architecture Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5069\u003c\/strong\u003e: Bulletin line identifier for CompactLogix 5380 platform hardware and local I\/O modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eL306\u003c\/strong\u003e: Processing capacity tier indicating 0.6 MB embedded user memory allocation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eE\u003c\/strong\u003e: Dual 10\/100\/1000 Mbps Ethernet communication ports for direct network topology integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR\u003c\/strong\u003e: Hardware execution supporting Device Level Ring (DLR) network redundancy modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM\u003c\/strong\u003e: Kinematic profile enabling integrated motion control over EtherNet\/IP networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5069-L306ERM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.84 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e145 x 135 x 90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e45 W max (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e0.6 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotion Axis Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 2 Position-Loop Axes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEtherNet\/IP Nodes\u003c\/td\u003e\n\u003ctd\u003e32 Nodes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Capacity\u003c\/td\u003e\n\u003ctd\u003eUp to 8 Local 5069 Compact I\/O Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Deterministic Networks \u0026amp; Firmware Flash Execution\u003c\/h3\u003e\n\u003cp\u003eThe processor manages time-critical motion loops across EtherNet\/IP deterministic networks via IEEE 1588 Precision Time Protocol (PTP). System synchronization relies on strict firmware flash compatibility, linking controller execution tasks directly to servo drives and remote I\/O blocks without cyclic clock drift. Dual embedded Ethernet ports execute high-speed packet routing to maintain ring topology integrity without overloading backplane communication paths.\u003c\/p\u003e\n\u003ch3\u003eOrder Manifest \u0026amp; Accessory Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 5069-L306ERM Motion Controller\u003c\/li\u003e\n\u003cli\u003e1 x Right-Side Backplane Bus End Cap Shield\u003c\/li\u003e\n\u003cli\u003e1 x 5069-RTB54 5-Pin Removable Terminal Block Assembly\u003c\/li\u003e\n\u003cli\u003e1 x Field Installation Instruction Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Wiring Execution\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDIN Rail Alignment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMount the unit onto a heavy-duty 35 mm zinc-plated steel DIN rail. Ensure adjacent 5069 local I\/O modules slide flush along side interlocking rails until rear bus pins lock completely.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Connector Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect 24 VDC external power using 14-16 AWG stranded copper wire to the 5069-RTB54 plug, separating System Power (MOD) from Field Power (SA) circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Earth Grounding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAttach a dedicated low-impedance copper ground braid from the rail terminal directly to the central panel enclosure earth bus to reject electromagnetic noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEthernet Field Cabling\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute shielded Cat6 STP cables through the bottom RJ45 ports, maintaining spatial isolation from high-voltage motor power leads and VFD output conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering \u0026amp; Hardware FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the controller support hot-swapping adjacent local I\/O modules?\u003c\/p\u003e\n\u003cp\u003eNo, removing or inserting local 5069 Compact I\/O modules while backplane power is active causes backplane bus faults and potential hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are real-time clock values retained during a total DC power failure?\u003c\/p\u003e\n\u003cp\u003eAn embedded non-battery energy storage module maintains internal memory long enough to write system states and clock data into non-volatile flash storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage range is permitted for the MOD power input block?\u003c\/p\u003e\n\u003cp\u003eThe controller operates from a nominal 24 VDC input, tolerating a strict operational voltage range between 18 and 32 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat maximum number of servo axes can be synchronized over EtherNet\/IP?\u003c\/p\u003e\n\u003cp\u003eThe 5069-L306ERM hardware profile supports up to 2 position-loop motion axes configured for CIP Motion execution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the dual Ethernet interfaces run on two separate IP subnet addresses?\u003c\/p\u003e\n\u003cp\u003eYes, when configured in Dual IP mode via Studio 5000, each RJ45 port manages an independent IP address and subnet mask.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the end cap shield is omitted from the rightmost I\/O module?\u003c\/p\u003e\n\u003cp\u003eLeaving the right side backplane connector exposed risks electrical short circuits, static discharge damage, and open backplane communication faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat torque setting is required for the power block screw terminals?\u003c\/p\u003e\n\u003cp\u003eTighten the terminal block wire clamping screws to a recommended torque of 0.5 to 0.6 Nm to ensure gas-tight contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are active network status errors indicated on the front panel?\u003c\/p\u003e\n\u003cp\u003eDiagnostic codes are shown on the scrolling 4-character status display alongside dedicated NET and MOD LED indicators.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47279685370029,"sku":"5069-L306ERM","price":1380.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley_5069-l306erm_2.jpg?v=1787207974","url":"https:\/\/www.maxwellplc.com\/ru\/products\/5069-l306erm-allen-bradley-programmable-automation-controller-compactlogix-5380","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}