{"product_id":"3g3mx2-a4055-zv1-omron-mx2-series-multi-function-compact-inverter","title":"3G3MX2-A4055-ZV1 Omron MX2 Series Multi-Function Compact Inverter","description":"\u003cp\u003eThe \u003cstrong\u003eOmron 3G3MX2-A4055-ZV1\u003c\/strong\u003e serves as the primary \u003cstrong\u003e3G3MX2\u003c\/strong\u003e Multi-Function Compact Inverter utilized to execute 3-phase 400 V AC motor velocity control and real-time torque regulation across industrial automation drive platforms.\u003c\/p\u003e\n\u003ch3\u003eVariant Decoder \u0026amp; System Catalog Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3G3MX2\u003c\/strong\u003e: Base inverter hardware platform for the MX2 Series drive architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA\u003c\/strong\u003e: Panel-mounting enclosure structural format (rated IP10 minimum) or closed wall-mounting layout.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4\u003c\/strong\u003e: 3-phase 400 VAC supply voltage class (380 V to 480 V operating range).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e055\u003c\/strong\u003e: Maximum applicable motor capacity of 5.5 kW under continuous heavy-duty (CT) loading profiles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZV1\u003c\/strong\u003e: Dedicated firmware integration profile and regional functional spec variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical \u0026amp; Electrical Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3MX2-A4055-ZV1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e14.0 cm x 18.0 cm x 17.0 cm (Shipping Weight: 6.0 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.5 kW rated output motor capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Input Voltage\u003c\/td\u003e\n\u003ctd\u003e3-phase 380 VAC to 480 VAC (+10%, -15%), 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP10 minimum panel-mounting enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Bus \u0026amp; Execution Logic\u003c\/h3\u003e\n\u003cp\u003eThe internal architecture leverages backplane bus communication velocity licences to preserve cycle synchronization across Profinet and EtherNet\/IP deterministic networks. Embedded control loops manage high I\/O density scaling, enabling direct processing of pulse train references up to 32 kHz. System microcode guarantees firmware flash compatibility across host controller platforms, preventing signal frame latency during coordinated multi-axis execution.\u003c\/p\u003e\n\u003ch3\u003eOrdering \u0026amp; Deliverable Component List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3MX2-A4055-ZV1 Drive Unit\u003c\/li\u003e\n\u003cli\u003e1 x Protective Terminal Guard\u003c\/li\u003e\n\u003cli\u003e1 x Installation Instructions Sheet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Installation \u0026amp; Field Wiring Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Clearance Rules\u003c\/p\u003e\n\u003cp\u003eMount the unit vertically against a metal panel backplate, maintaining at least 100 mm clearance above and below the cooling heatsink to ensure adequate thermal airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Routing Protocol\u003c\/p\u003e\n\u003cp\u003eMaintain a physical separation distance of at least 100 mm between 400 V AC power leads and low-voltage DC control wires to prevent electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective Earthing Connection\u003c\/p\u003e\n\u003cp\u003eConnect a dedicated grounding wire directly from the protective earth terminal to the main panel ground bus; do not series-loop earth connections across multiple units.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan terminal block connections be altered while power is supplied to the drive?\u003c\/p\u003e\n\u003cp\u003eNo. Main AC power must be disconnected and internal DC bus voltage verified below 50 VDC using a multimeter before touching terminal screws.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat activation time applies to the internal dual safety input system?\u003c\/p\u003e\n\u003cp\u003eDual safety inputs execute direct gate driver shutdown within 10 milliseconds, removing motor torque in compliance with ISO 13849-1 Cat 3 PLd standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the internal serial interface resist industrial line noise spikes?\u003c\/p\u003e\n\u003cp\u003eThe integrated RS485 communication transceiver features galvanic isolation, shielding internal logic from differential ground offsets and common-mode noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the drive capable of operating high-frequency motors above standard mains limits?\u003c\/p\u003e\n\u003cp\u003eYes. Adjustable internal registers allow output operation up to 1000 Hz, provided motor winding insulation and mechanical bearings tolerate high frequencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external dynamic braking unit required for low-inertia stop cycles?\u003c\/p\u003e\n\u003cp\u003eNo. Internal braking choppers manage standard stopping; external resistors are required only when high-inertia load regeneration exceeds thermal capacity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does high ambient temperature affect continuous current output capacity?\u003c\/p\u003e\n\u003cp\u003eContinuous output current ratings must be derated by 2.5% per deg C for operating environments continuously exceeding 40 deg C up to 50 deg C max.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre internal configuration parameters preserved across total primary power loss cycles?\u003c\/p\u003e\n\u003cp\u003eYes. Drive parameters, custom V\/f profiles, and error history logs are permanently stored in internal non-volatile EEPROM memory without battery power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat grounding rule prevents signal distortion on analog reference control lines?\u003c\/p\u003e\n\u003cp\u003eGround the braided cable shield to the drive earth terminal on the inverter side only to prevent circulating ground loop currents from skewing signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306651467949,"sku":"3G3MX2-A4055-ZV1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3G3MX2-A4055-ZV1_1.jpg?v=1787722798","url":"https:\/\/www.maxwellplc.com\/ru\/products\/3g3mx2-a4055-zv1-omron-mx2-series-multi-function-compact-inverter","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}