{"product_id":"3g3jz-a4007-omron-inverter-sysdrive-3g3jz-series","title":"3G3JZ-A4007 Omron Inverter SYSDRIVE 3G3JZ Series","description":"\u003cp\u003eConfigured for variable-speed control of three-phase motors, the \u003cstrong\u003eOmron 3G3JZ-A4007\u003c\/strong\u003e (\u003cstrong\u003e3G3JZ\u003c\/strong\u003e inverter) provides V\/f-based motor control from a 400 V-class three-phase supply. The unit is rated for motors up to 0.75 kW and provides a rated output current of 2.5 A.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe model designation separates the 3G3JZ series, enclosure type, voltage class, and applicable motor capacity. Omron documentation identifies the A4007 as a panel-mounting model with an IP20 minimum enclosure structure and three-phase AC400 V class input.\u003c\/p\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eCode\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e3G3JZ\u003c\/td\u003e\n\u003ctd\u003eSYSDRIVE 3G3JZ series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003ePanel-mounting model, IP20 minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eThree-phase AC400 V class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e007\u003c\/td\u003e\n\u003ctd\u003eMaximum applicable motor capacity: 0.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComplete model\u003c\/td\u003e\n\u003ctd\u003e3G3JZ-A4007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3G3JZ-A4007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eOmron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSYSDRIVE 3G3JZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAC Inverter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003eThree-phase AC380 to 480 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003eApprox. 3.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Motor Capacity\u003c\/td\u003e\n\u003ctd\u003e0.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e2.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003eThree-phase, up to input voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Frequency Range\u003c\/td\u003e\n\u003ctd\u003e0.1 to 600 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Method\u003c\/td\u003e\n\u003ctd\u003eV\/f control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarrier Frequency\u003c\/td\u003e\n\u003ctd\u003e2 to 15 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485, standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003ePanel-mounting, IP20 minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling\u003c\/td\u003e\n\u003ctd\u003eSelf-cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Torque Function\u003c\/td\u003e\n\u003ctd\u003eMore than 150% torque at 3 Hz with torque boost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to +50 deg C; -10 to +40 deg C for close mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e90% RH or less, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot separately specified; rated motor capacity is 0.75 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 1.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Weight\u003c\/td\u003e\n\u003ctd\u003eApprox. 3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Dimensions\u003c\/td\u003e\n\u003ctd\u003eApprox. 72 x 135.7 x 174 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003eNot published in the referenced Omron documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eChina marking appears in the referenced product documentation; verify nameplate for individual unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe 3G3JZ-A4007 has a rated output current of 2.5 A. The documented 3G3JZ-A4007 installation dimensions fall within the 72 x 135.7 x 174 mm frame group.\u003c\/p\u003e\n\u003ch3\u003eIndustrial Drive and Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3G3JZ series uses V\/f control as its primary motor-control method. The A4007 variant is intended for three-phase 400 V-class power systems and is matched to motors up to 0.75 kW.\u003c\/p\u003e\n\u003cp\u003eStandard RS485 communication permits connection to a PLC or host controller. The documentation identifies RS485 as a standard interface for control and monitoring applications.\u003c\/p\u003e\n\u003cp\u003eThe inverter also provides six multifunction input terminals. Parameter-based operation can be used for frequency and command control without requiring every operating function to be hardwired.\u003c\/p\u003e\n\u003cp\u003eThe adjustable carrier frequency range is 2 to 15 kHz. A torque-boost function can provide more than 150% torque at 3 Hz under the specified operating conditions.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Omron 3G3JZ-A4007 AC Inverter\u003c\/li\u003e\n\u003cli\u003e1 x Safety Precautions documentation, where supplied with the unit\u003c\/li\u003e\n\u003cli\u003eMounting screws and installation hardware are not identified as standard supplied accessories and should be provided by the installer.\u003c\/li\u003e\n\u003cli\u003eExternal braking or other optional equipment is not included unless separately specified.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Wiring\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the inverter vertically with the nameplate orientation readable from the front.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 120 mm clearance above and below the inverter for normal heat dissipation.\u003c\/li\u003e\n\u003cli\u003eMaintain at least 50 mm lateral spacing for normal mounting conditions.\u003c\/li\u003e\n\u003cli\u003eFor close mounting, the allowable operating temperature is reduced to -10 to +40 deg C.\u003c\/li\u003e\n\u003cli\u003eInstall the unit in a clean location without excessive oil mist, dust, metal particles, or water.\u003c\/li\u003e\n\u003cli\u003eIf the surrounding environment contains floating contaminants, use a suitable enclosed control panel.\u003c\/li\u003e\n\u003cli\u003eDo not mount the inverter on combustible materials.\u003c\/li\u003e\n\u003cli\u003eConnect the three-phase input to R\/L1, S\/L2, and T\/L3.\u003c\/li\u003e\n\u003cli\u003eConnect motor output terminals to U\/T1, V\/T2, and W\/T3.\u003c\/li\u003e\n\u003cli\u003eUse an appropriate protective circuit breaker for the inverter supply.\u003c\/li\u003e\n\u003cli\u003eFor control wiring, use shielded cable where required and terminate the shield according to the installation manual.\u003c\/li\u003e\n\u003cli\u003eKeep control wiring separated from high-current motor and power wiring to reduce electrical interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe documented installation requirements specify vertical mounting and minimum heat-dissipation clearances for the A4004 to A4007 400 V models.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat motor rating is specified for the 3G3JZ-A4007?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe maximum applicable motor capacity is 0.75 kW. The rated inverter output current is 2.5 A.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat input supply does the A4007 require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is the three-phase 400 V class version. Published electrical data specifies approximately 380 to 480 V AC at 50\/60 Hz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat control method does this inverter use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 3G3JZ series is based on V\/f control. Torque boost is available for low-frequency motor operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the inverter have RS485 communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. RS485 is provided as a standard communication interface and can be used for PLC or host-controller communication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the rated output current?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified rated output current for the 3G3JZ-A4007 is 2.5 A. This value should be considered when matching the inverter to the motor load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the operating temperature range?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNormal panel mounting permits -10 to +50 deg C. Close mounting reduces the specified range to -10 to +40 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat mounting clearance is required?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe documented installation arrangement requires at least 120 mm above and below the unit and at least 50 mm lateral clearance under normal mounting conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the A4007 fan-cooled?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe 0.75 kW A4007 is identified as a self-cooling model without a cooling fan. Ventilation clearance must therefore be maintained around the enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Omron","offers":[{"title":"Default Title","offer_id":47306608312493,"sku":"3G3JZ-A4007","price":168.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/omron_3g3jz-a4007_1.jpg?v=1787719906","url":"https:\/\/www.maxwellplc.com\/ru\/products\/3g3jz-a4007-omron-inverter-sysdrive-3g3jz-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}