{"product_id":"3bse028588r1-do880-1-abb-s800-i-o-digital-output-module","title":"3BSE028588R1 DO880-1 ABB S800 I\/O Digital Output Module","description":"\u003cp\u003eConfigured for current-sourcing discrete load control in S800 I\/O architectures, the \u003cb\u003eABB 3BSE028588R1 DO880-1\u003c\/b\u003e (\u003cb\u003eDO880-1\u003c\/b\u003e Digital Output Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eChannel Topologies \u0026amp; Operational Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eChannel Density\u003c\/b\u003e: Integrates 16 discrete current-sourcing output channels operating at a nominal 24 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRedundancy Support\u003c\/b\u003e: Operates in either single-module or dual-redundant configurations for fault-tolerant automation architectures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDiagnostic Execution\u003c\/b\u003e: Features built-in channel diagnostics, visual LED output status indicators, and degraded mode execution for normally energized loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BSE028588R1 DO880-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSWEDEN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Output Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eS800 I\/O\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChannels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e16 points\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (19.2 to 32 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 A per channel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Characteristics\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCurrent sourcing, current limiting\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConfiguration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle or redundant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNet Weight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.24 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.6 x 11 x 11.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDependent on backplane bus load (Not specified)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Bus Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe output circuits process control commands sent across backplane bus communication velocity Licences to achieve deterministic point updates. Embedded current-limiting circuitry protects outputs against short circuits without compromising system execution speed. Module memory flash compatibility ensures seamless integration with active System 800xA control software revisions.\u003c\/p\u003e\n\u003ch3\u003eStandard Delivery Manifest\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB 3BSE028588R1 DO880-1 Digital Output Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Product Hardware Release Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation \u0026amp; Terminal Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eBase Termination Mounting\u003c\/b\u003e: Snap the module onto the designated S800 I\/O terminal base plate (TU880 or TU881) until physical guide pins lock into place.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eRedundancy Setup\u003c\/b\u003e: Place twin DO880-1 modules on redundant ModuleBus base units to maintain seamless output takeover upon channel failure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003ePower Connections\u003c\/b\u003e: Connect external 24 VDC power through fused field supply lines, maintaining loop voltage within the 19.2 to 32 VDC tolerance band.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eGrounding Standards\u003c\/b\u003e: Secure functional earth conductors directly to the DIN rail or backplane base mounting frame to discharge transient interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the channel density and signal configuration of this module?\u003c\/p\u003e\n\u003cp\u003eThe hardware features 16 current-sourcing digital output channels rated for 24 VDC (19.2 to 32 VDC) at 0.5 A per point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the output module support fault-tolerant redundant installation?\u003c\/p\u003e\n\u003cp\u003eYes, the module can be deployed in single-channel or dual-redundant configurations using compatible S800 I\/O base plates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the module handle short circuits on connected field output loops?\u003c\/p\u003e\n\u003cp\u003eEach output channel incorporates active current-limiting protection to prevent internal module damage during short-circuit faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat does degraded mode execution mean for normally energized channels?\u003c\/p\u003e\n\u003cp\u003eDegraded mode keeps output loops energized during minor fault states, preventing unexpected process trips in safety-critical systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this module be hot-swapped without de-energizing the ModuleBus backplane?\u003c\/p\u003e\n\u003cp\u003eYes, S800 I\/O modules support live insertion and removal when installed on compatible ModuleBus terminal bases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are output state and channel status communicated to maintenance personnel?\u003c\/p\u003e\n\u003cp\u003eIndividual LED indicators on the module front panel display real-time channel status and hardware fault diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable shielding parameters must be followed during site wiring?\u003c\/p\u003e\n\u003cp\u003eField signal cables must use shielded twisted pairs grounded at a single chassis ground point to prevent loop noise coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are outputs isolated from internal controller system logic?\u003c\/p\u003e\n\u003cp\u003eInternal optocoupler isolation circuits separate low-voltage system backplane logic from external 24 VDC field output circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021085462701,"sku":"3BSE028588R1 DO880-1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_3bse028588r1_do880-1_1.jpg?v=1787398222","url":"https:\/\/www.maxwellplc.com\/ru\/products\/3bse028588r1-do880-1-abb-s800-i-o-digital-output-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}