{"product_id":"3bse013230r1-abb-tu810v1-compact-mtu-s800-i-o","title":"3BSE013230R1 ABB TU810V1 Compact MTU S800 I\/O","description":"\u003cp\u003eConfigured for field device signal termination within S800 I\/O architectures, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB TU810V1 3BSE013230R1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eTU810V1 3BSE013230R1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCompact MTU) provides direct physical signal conditioning and electrical distribution. This hardware component serves as the mechanical and electrical base for I\/O modules, enabling the transfer of analog and digital signals between field-mounted instrumentation and the DCS controller bus.\u003c\/p\u003e\n\u003ch3\u003ePart Number Configuration\u003c\/h3\u003e\n\u003cp\u003eThe TU810V1 3BSE013230R1 is a modular termination unit designed for high-density I\/O cabinet layouts. This part number signifies the compact form factor MTU, which supports terminal-level signal routing. No internal jumpers or configuration settings are required at the MTU level, as signal paths are defined by the insertion of the specific S800 I\/O module into the termination base.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTU810V1 3BSE013230R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.22 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e17.0 x 6.5 x 6.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (Nominal)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eABB Industrial Control \u0026amp; Drive Communication\u003c\/h3\u003e\n\u003cp\u003eThe MTU utilizes high-speed backplane bus communication to maintain deterministic signal paths between the field I\/O and the S800 controller. This architecture supports high I\/O density scaling within the control cabinet while ensuring minimal signal latency. The module is fully compatible with firmware flash update procedures for the attached I\/O modules, allowing for system-wide performance optimization and integration within Profinet or EtherNet\/IP-supported DCS environments.\u003c\/p\u003e\n\u003ch3\u003e## Ordering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTU810V1 3BSE013230R1 termination unit module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct delivered in anti-static protective packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard technical installation documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSnap the MTU onto a standard 35 mm DIN-rail until the locking mechanism clicks into position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure adjacent MTUs are properly aligned to facilitate the internal module-to-module power distribution bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnect field wiring to the screw or spring-loaded terminals according to the specific I\/O module wiring diagram.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure all cable shields are terminated at the provided field-side grounding points to maximize EMI immunity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify power supply polarity for the 24 VDC bus before inserting the active S800 I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the MTU perform signal processing?\u003c\/p\u003e\n\u003cp\u003eA: No, the MTU is a passive termination base; signal conditioning and conversion are performed by the inserted S800 I\/O module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the unit be replaced while the system is powered?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the S800 I\/O system supports hot-swapping; however, ensure the attached field wiring is safe before module removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the unit maintain 1500 V isolation?\u003c\/p\u003e\n\u003cp\u003eA: Isolation is maintained through the dielectric design of the MTU housing and the physical separation of terminal rows from the backplane bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the MTU compatible with all S800 I\/O modules?\u003c\/p\u003e\n\u003cp\u003eA: The TU810V1 is compatible with specific S800 I\/O module types; verify the module compatibility list before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates a power supply failure on the MTU?\u003c\/p\u003e\n\u003cp\u003eA: Power status is monitored via the LED indicators on the attached S800 I\/O module; the MTU itself does not have active diagnostic LEDs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this MTU in high-vibration areas?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the unit is designed for industrial applications and meets vibration standards for cabinet-mounted electronic equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How are ground loops avoided?\u003c\/p\u003e\n\u003cp\u003eA: Ground loops are prevented by following the single-point grounding convention for field shields at the MTU termination level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the MTU require firmware?\u003c\/p\u003e\n\u003cp\u003eA: No, the MTU is a passive mechanical and electrical interface; it contains no firmware or programmable logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231200698541,"sku":"3BSE013230R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-tu810v1-3bse013230r1-compact-module-termination-unit-mtu-ovmygt2xcfu_86eef1e8-2644-4acc-a25a-4eebdc10e088.jpg?v=1762942504","url":"https:\/\/www.maxwellplc.com\/ru\/products\/3bse013230r1-abb-tu810v1-compact-mtu-s800-i-o","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}