{"product_id":"3bse013036r1-abb-pfpk-122-circuit-board-advant-ocs-800xa","title":"3BSE013036R1 ABB PFPK 122 Circuit Board Advant OCS 800xA","description":"\u003cp\u003eConfigured for signal conditioning in Advant OCS and 800xA systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB PFPK 122\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e3BSE013036R1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCircuit Board) provides direct physical\/electrical execution of I\/O signal processing. This module supports the conversion and isolation of 24 VDC digital signals as well as 4–20 mA and 0–10 V analog inputs. It maintains 1500 VAC field-to-system isolation and 250 VAC channel-to-channel isolation to prevent crosstalk and electrical noise interference. The hardware facilitates data acquisition and control within distributed architectures, ensuring that signal integrity is preserved across the specified temperature range of -25 deg C to +70 deg C.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe PFPK 122 (3BSE013036R1) is a single-variant circuit board. There are no configurable hardware suffixes or modular matrices associated with this part number.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePFPK 122\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.4 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 x 25.8 x 24.3 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤ 4 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSignal Types\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC Digital, 4–20 mA\/0–10 V Analog\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1500 VAC (Field-to-System), 250 VAC (Channel-to-Channel)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eControl System Integration\u003c\/h3\u003e\n\u003cp\u003eThe PFPK 122 is engineered for seamless operation within ABB DCS platforms, where backplane bus communication velocity and I\/O density scaling are required for large-scale automation. The module supports firmware flash compatibility, allowing for protocol updates or diagnostic logic adjustments via the control network. Its circuitry is optimized to maintain I\/O synchronization during high-speed polling cycles. The module's internal monitoring logic reports channel status to the central processor, ensuring that I\/O mapping remains accurate within the DCS database.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePFPK 122 Circuit Board unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eESD-protected packaging\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical documentation\/manual insert\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo mounting baseplates or field connectors included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: The module is designed for DIN-rail installation; ensure the rail is securely bonded to the cabinet ground to establish a stable reference potential.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring: Terminate all analog signal wiring with shielded twisted-pair cables; ground the shield at the cabinet entry point only.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparation: Route digital I\/O lines and analog signal lines separately to minimize potential induction noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnections: Use ferruled conductors for screw clamp terminals to ensure long-term mechanical stability under vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerification: Inspect terminal seating before power-up to ensure correct polarity for 24 VDC inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the module hot-swappable?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: No, the system backplane must be de-energized to prevent short-circuiting signal pins during module extraction or insertion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I mix analog and digital signal types on the same module?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The module is designed to handle the specified I\/O types; refer to the wiring diagram for specific channel assignment capabilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does the module handle channel-to-channel noise?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Each channel is protected by 250 VAC isolation, which effectively suppresses crosstalk and prevents potential differences between connected field loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the input voltage range auto-adjusting?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: The module operates at 24 VDC ±10%; ensure the power supply is strictly regulated within this window to prevent hardware damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the module be configured for redundant I\/O?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Redundancy support is determined by the system backplane and controller configuration; verify compatibility with your specific 800xA rack setup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the 1500 VAC field-to-system isolation?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: This isolation barrier prevents high-voltage faults on the field wiring from propagating into the central control system and backplane logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the module require periodic calibration?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Analog conversion precision is maintained by internal reference circuitry; routine calibration is not required under normal industrial operating conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How are diagnostic errors reported?\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eA: Module faults are reported through the system communication bus, which triggers specific alarm bits in the DCS diagnostic environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231176941741,"sku":"3BSE013036R1","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-pfpk122-3bse013036r1-circuit-board-qnquehgnvtm_f0232a9e-9d28-4416-9f88-285eb40ce4cc.jpg?v=1762942308","url":"https:\/\/www.maxwellplc.com\/ru\/products\/3bse013036r1-abb-pfpk-122-circuit-board-advant-ocs-800xa","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}