{"product_id":"3bse009858r1-abb-nioc-01c-i-o-modules","title":"3BSE009858R1 ABB NIOC-01C I\/O Modules","description":"\u003cp\u003eConfigured for high-capacity communication in distributed control systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eABB NIOC-01C 3BSE009858R1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eNIOC-01C 3BSE009858R1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eI\/O Modules) provides direct physical execution of data exchange between central controllers and remote field-level devices. The module integrates a 32-bit RISC processor to handle deterministic communication tasks and multi-channel fieldbus synchronization.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe NIOC-01C 3BSE009858R1 serves as the primary communication interface for S800 I\/O clusters. This module architecture is optimized for high-density I\/O mapping and provides the necessary processing overhead to maintain data integrity across distributed automation nodes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNIOC-01C 3BSE009858R1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10.2 x 27.9 x 7.6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-25 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProcessor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32-bit RISC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eABB Industrial Control \u0026amp; Drive Communication\u003c\/h3\u003e\n\u003cp\u003eThe NIOC-01C utilizes deterministic PROFIBUS-DP connectivity to ensure rapid data throughput within distributed automation networks. The module supports I\/O density scaling, enabling the management of up to 128 S800 I\/O modules via a single controller interface. Its architecture includes firmware flash compatibility to support system-wide diagnostic updates and high backplane bus communication velocity, ensuring that field-side process data is synchronized with the central controller scan cycle without latency bottlenecks.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNIOC-01C 3BSE009858R1 communication module unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical documentation for PROFIBUS configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eESD-safe industrial packaging.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the module on a standard horizontal or vertical mounting rail within the I\/O cluster.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the module is seated securely into the I\/O base plate to maintain backplane contact and minimize mechanical vibration effects.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnect PROFIBUS-DP fieldbus cables to the designated interface terminals, ensuring proper shield termination to the cabinet ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvide a stable 24 VDC (±10%) supply voltage; monitor voltage levels at the module power terminals to prevent operational brown-outs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the NIOC-01C support hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is designed for hot-swapping in supported S800 I\/O base configurations, allowing for replacement without de-energizing the entire I\/O rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this module interface with non-S800 I\/O?\u003c\/p\u003e\n\u003cp\u003eA: It is purpose-built for the S800 I\/O series; interfacing with other I\/O families is not supported within this specific architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the PROFIBUS-DP address configured?\u003c\/p\u003e\n\u003cp\u003eA: The address is typically assigned through the controller software or via physical address switches on the module base plate, depending on the system configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What indicates a communication fault on the bus?\u003c\/p\u003e\n\u003cp\u003eA: Diagnostic LEDs on the module front panel display specific error codes related to PROFIBUS-DP status and internal system health.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How much power does the module draw under full load?\u003c\/p\u003e\n\u003cp\u003eA: The typical power consumption is 5 W; ensure the cabinet power supply is sized to account for total cluster current requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the module support dual-channel communication for redundancy?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the architecture includes dual-channel interfaces to improve communication availability in critical process environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum number of I\/O nodes?\u003c\/p\u003e\n\u003cp\u003eA: The module can manage up to 128 S800 I\/O modules, subject to the specific controller memory and scan cycle limitations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I update the module firmware?\u003c\/p\u003e\n\u003cp\u003eA: Firmware updates are performed through the engineering station connected to the controller, which propagates the update to the NIOC-01C via the backplane.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45231195160749,"sku":"3BSE009858R1","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb-nioc-01c-3bse009858r1-i-o-module-zpma1f4s3aq_410e7fe3-961c-4277-ac09-ca9b7f182e54.jpg?v=1762942456","url":"https:\/\/www.maxwellplc.com\/ru\/products\/3bse009858r1-abb-nioc-01c-i-o-modules","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}