{"product_id":"3bhe021887r0101-ubcc717be101-abb-vvp-board-ac-800pec","title":"3BHE021887R0101 UBCC717BE101 ABB VVP Board AC 800PEC","description":"\u003cp\u003eThe \u003cstrong\u003eABB 3BHE021887R0101 UBCC717BE101\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eUBCC717BE101\u003c\/strong\u003e VVP Board Coated, operates as a dedicated hardware component for pulse processing and interface management within \u003cstrong\u003eAC 800PEC\u003c\/strong\u003e control systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering Code Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eUBCC717BE101\u003c\/strong\u003e: Specific hardware revision designation and PC board module function.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3BHE021887R0101\u003c\/strong\u003e: Primary ABB part number identification code.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVVP Board Coated\u003c\/strong\u003e: Hardware configuration featuring conformal coating for environmental protection against atmospheric contaminants and moisture.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical \u0026amp; Technical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3BHE021887R0101 UBCC717BE101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePC Board (VVP-Board Coated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eAC 800PEC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.64 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e35 x 29 x 6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoating\u003c\/td\u003e\n\u003ctd\u003eConformal Coated Board\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Communication \u0026amp; Deterministic Processing\u003c\/h3\u003e\n\u003cp\u003eThe module interfaces directly with the high-speed AC 800PEC backplane bus communication velocity. Internal circuitry handles high-speed pulse feedback processing and signal conditioning required for high-power semiconductor drive systems. Deterministic response times ensure synchronization across the internal bus architecture, while firmware flash compatibility ensures alignment with the host AC 800PEC controller version.\u003c\/p\u003e\n\u003ch3\u003eOrder Fulfillment Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x ABB 3BHE021887R0101 UBCC717BE101 VVP Board Coated\u003c\/li\u003e\n\u003cli\u003e1x Factory ESD protective packaging enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Installation \u0026amp; Wiring Protocols\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHandling and ESD Safeguards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMaintain grounded wrist strap connection during handling to prevent electrostatic damage.\u003c\/li\u003e\n\u003cli\u003eKeep the board inside conductive ESD packaging until immediate insertion into the rack frame.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCabinet Mounting and Clearance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMount horizontally within the designated subrack slot using guide rails.\u003c\/li\u003e\n\u003cli\u003eEnsure a minimum vertical clearance of 50 mm above and below the rack for free air convection.\u003c\/li\u003e\n\u003cli\u003eSecure retention screws with a torque limit of 0.8 Nm to ensure proper ground contact and mechanical stability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Shielding and Earth Grounding\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConnect cable shields directly to the cabinet ground bar using low-impedance grounding clamps.\u003c\/li\u003e\n\u003cli\u003eSeparate high-voltage power conduits from low-voltage I\/O and communication lines by at least 200 mm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the significance of the conformal coating on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe coating shields electronic components from humidity, dust, and corrosive airborne contaminants present in industrial drive environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the UBCC717BE101 board hot-swappable during operation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Power to the AC 800PEC subrack must be completely de-energized before removing or installing the board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow is chassis ground continuity established for the circuit board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eGround continuity relies on direct contact between the board metal frame, guide rails, and cabinet earth ground bar.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the proper procedure for storing a spare VVP board?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eStore the module inside its original sealed ESD shielding bag at temperatures between -40 deg C and +70 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this unit require a dedicated external power supply connection?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOperating power is drawn directly through the backplane connection interface of the AC 800PEC subrack assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the firmware on the board be upgraded independently?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility is synchronized automatically through the main controller loading routine upon system startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable type is required for external I\/O terminals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUse twisted-pair shielded cables with a minimum copper cross-section of 0.5 mm2 (AWG 20) for noise suppression.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I verify physical seating after insertion into the rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify that front panel retention screws line up properly and thread smoothly without forcing the connector pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021045223597,"sku":"3BHE021887R0101 UBCC717BE101","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/3BHE021887R0101_1.jpg?v=1787895469","url":"https:\/\/www.maxwellplc.com\/ru\/products\/3bhe021887r0101-ubcc717be101-abb-vvp-board-ac-800pec","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}