{"product_id":"3bhe016011r0002-uns0118a-z-abb-control-module-ac-800pec","title":"3BHE016011R0002 UNS0118a-Z ABB Control Module AC 800PEC","description":"\u003cp\u003eConfigured for high-speed digital task execution and real-time fieldbus processing in AC 800PEC architectures, the \u003cb\u003eABB 3BHE016011R0002 UNS0118a-Z\u003c\/b\u003e (\u003cb\u003eUNS0118a-Z\u003c\/b\u003e Control Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Variant Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eUNS0118a-Z\u003c\/b\u003e: Hardware revision reference and specific control card board topology.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003e3BHE016011R0002\u003c\/b\u003e: Primary system ordering part number assigned by ABB.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eAC 800PEC\u003c\/b\u003e: Targeted high-performance controller platform designed for power electronics application processing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3BHE016011R0002 UNS0118a-Z\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eABB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProduct Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eControl Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSeries\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC 800PEC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCountry of Origin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSweden\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNominal Supply Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 VDC (+\/-20%)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 W\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +60 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +85 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5% to 95% (non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFieldbus Protocols\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAN, Modbus\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.94 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.5 x 24.5 x 26.1 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBus Communication and Firmware Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe unit integrates with deterministically prioritized backplane communication channels to achieve continuous I\/O density scaling across system subracks. Internal microprocessor buses enforce firmware flash compatibility protocols during system initialization, maintaining low-latency data exchange across active CAN and Modbus communication loops without introducing process signal jitter.\u003c\/p\u003e\n\u003ch3\u003eSystem Shipment Package\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e1 x ABB 3BHE016011R0002 UNS0118a-Z Control Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Anti-static ESD protective shipping box\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Mounting and Wiring Recommendations\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eCabinet Integration\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSlide the module smoothly along subrack card guides to prevent pin deformation on backplane connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTorquing front-panel locking fasteners to 0.6 Nm secures chassis grounding and prevents vibration dislodgements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cb\u003ePower and Signal Wiring\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the 24 VDC auxiliary power supply leads through dedicated, fused terminal blocks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate CAN and Modbus communication cabling from high-voltage AC motor lines by a minimum of 200 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround all overall cable shields to the local earth busbar via low-impedance grounding clamps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support FAQs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWhat is the primary input voltage requirement for this control module?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe unit operates on a nominal 24 VDC power supply with an acceptable input voltage tolerance of +\/-20%.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eCan this module be hot-swapped while the rack backplane is energized?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Main system power must be disconnected before removing or inserting the unit to prevent electrical transients.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWhat fieldbus protocols are natively supported on the board communication interfaces?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe hardware features integrated controller support for CAN bus and Modbus fieldbus protocol communications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eHow is electrical noise immunity maintained on fieldbus signal cables?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eShielded twisted-pair cables must be utilized, with shields grounded at the entry point of the control panel.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWhat is the typical thermal dissipation of the card during operation?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe internal power dissipation of the unit remains at approximately 10 W under nominal operational loads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eDoes the module require external forced-air cooling in standard cabinets?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eStandard passive convection cooling is sufficient if ambient temperatures remain between -20 and +60 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eHow are firmware mismatches handled upon system startup?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility checking ensures the module synchronizes with the controller configuration on boot.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cb\u003eWhat is the recommended storage temperature range for spare units?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eSpare modules must be stored within a dry environment maintained between -40 deg C and +85 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":46021079498925,"sku":"3BHE016011R0002 UNS0118a-Z","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/abb_3bhe016011r0002_uns0118a-z_1.jpg?v=1787894808","url":"https:\/\/www.maxwellplc.com\/ru\/products\/3bhe016011r0002-uns0118a-z-abb-control-module-ac-800pec","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}