{"product_id":"3500-92-136188-01-bently-nevada-ethernet-rs232-modbus-i-o-module","title":"3500\/92 136188-01 Bently Nevada Ethernet\/RS232 Modbus I\/O Module","description":"\u003cp\u003eConfigured for Modbus data communication in the Bently Nevada 3500 Series, the \u003cstrong\u003eBently Nevada 3500\/92 136188-01\u003c\/strong\u003e (\u003cstrong\u003e136188-01 Ethernet\/RS232 Modbus I\/O Module\u003c\/strong\u003e) provides Ethernet and RS232 physical interfaces for transferring rack monitoring data to external systems.\u003c\/p\u003e\n\u003ch3\u003eModel Identification\u003c\/h3\u003e\n\u003cp\u003eThe 136188-01 is identified as the Ethernet\/RS232 Modbus I\/O module associated with the 3500\/92 Communication Gateway. It provides the external communication interfaces; the 3500\/92 gateway module performs the rack-level communication function. Bently Nevada documentation lists 136188-01 as the Ethernet\/RS232 Modbus I\/O module for the 3500\/92 system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3500\/92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e136188-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e3500 Series Machinery Protection System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eEthernet\/RS232 Modbus I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eModbus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003eRS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Function\u003c\/td\u003e\n\u003ctd\u003e3500\/92 Communication Gateway I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation\u003c\/td\u003e\n\u003ctd\u003eRear I\/O slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e24.2 cm x 11.2 cm x 2.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003cp\u003eThe 3500\/92 system documentation identifies 136188-01 as the Ethernet\/RS232 Modbus I\/O module and distinguishes it from 136188-02, which uses an Ethernet\/RS485 interface.\u003c\/p\u003e\n\u003ch3\u003eMachinery Data Communication\u003c\/h3\u003e\n\u003cp\u003eThe module provides the physical communication path between the 3500 rack and external control or monitoring equipment. Data originating from machinery monitoring modules can be transferred through the 3500\/92 communication architecture.\u003c\/p\u003e\n\u003cp\u003eFor vibration and rotor-dynamics applications, the communication path can carry monitored values and status information associated with parameters such as shaft vibration, position, speed, and alarm states. The 136188-01 itself should not be treated as an eddy-current probe signal conditioner; probe scaling and gap-voltage processing are functions of the applicable monitoring channels.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 3500\/92 136188-01 Ethernet\/RS232 Modbus I\/O Module\u003c\/li\u003e\n\u003cli\u003e1 x Installed I\/O module assembly\u003c\/li\u003e\n\u003cli\u003eNo separate communication gateway main module is included unless specifically stated in the order\u003c\/li\u003e\n\u003cli\u003eCables, firmware kits, mounting accessories, and documentation are not assumed unless specifically listed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRack Position\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInstall the module in the designated rear I\/O position associated with the 3500\/92 configuration.\u003c\/li\u003e\n\u003cli\u003eConfirm that the installed gateway module and I\/O module configuration are compatible before energizing the rack.\u003c\/li\u003e\n\u003cli\u003eDo not force the module into the rack connector if mechanical alignment is incorrect.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCommunication Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRoute Ethernet and RS232 wiring separately from high-voltage switching conductors where practical.\u003c\/li\u003e\n\u003cli\u003eMaintain shield continuity according to the applicable plant grounding scheme.\u003c\/li\u003e\n\u003cli\u003eAvoid routing communication cables parallel to high-current motor or contactor wiring over long distances.\u003c\/li\u003e\n\u003cli\u003eVerify connector seating before applying power or initiating communication.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm the installed 3500\/92 gateway firmware and I\/O configuration before replacing an existing module.\u003c\/li\u003e\n\u003cli\u003eBently Nevada documentation notes that older Communication Gateway modules may require a firmware upgrade when used with newer I\/O modules.\u003c\/li\u003e\n\u003cli\u003eVerify the required Modbus interface type before substitution with another 3500\/92 I\/O variant.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs 136188-01 the main 3500\/92 gateway module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. 136188-01 is the Ethernet\/RS232 Modbus I\/O module. The 3500\/92 communication gateway main module is a separate hardware assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhich serial interface is provided by 136188-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe specified serial interface is RS232. The module is paired with Ethernet communication for the 3500\/92 gateway architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes 136188-01 perform vibration measurement directly?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. It provides the communication interface for rack data. Vibration measurement and signal conditioning are performed by the applicable 3500 monitoring modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan 136188-01 be replaced directly by 136188-02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNot without checking the required interface configuration. 136188-01 uses Ethernet and RS232, while 136188-02 is listed as the Ethernet\/RS485 variant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the module installed in the front or rear of the rack?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe supplied specification identifies it as a rear I\/O module. Installation should follow the designated 3500 rack position and mechanical keying.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs the operating temperature specified for this part?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo operating temperature is provided in the supplied technical data. A site-specific temperature rating should therefore be confirmed from the applicable Bently Nevada documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs power consumption specified for 136188-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo definitive power-consumption value is included in the supplied data. The value should not be inferred from another 3500 module or I\/O variant.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan older 3500\/92 hardware use this I\/O module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCompatibility depends on the gateway hardware and firmware revision. Bently Nevada documentation states that some older gateway modules require a firmware upgrade for newer I\/O modules.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45558886957229,"sku":"136188-01","price":799.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/136188-01-2__2.jpg?v=1767842397","url":"https:\/\/www.maxwellplc.com\/ru\/products\/3500-92-136188-01-bently-nevada-ethernet-rs232-modbus-i-o-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}