{"product_id":"3500-90-125728-01-bently-nevada-communication-gateway-module-3500-series","title":"3500\/90 125728-01 Bently Nevada Communication Gateway Module 3500 Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 3500\/90 125728-01\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e3500\/90\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCommunication Gateway module, operates as a dedicated hardware component for high-speed data transmission within 3500 Machinery Protection System platforms.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration Architecture\u003c\/h3\u003e\n\u003cp\u003eThe identifier 3500\/90 combined with part number 125728-01 specifies a factory-assembled internal communications interface card. This alphanumeric combination describes a permanent processing layout equipped with proprietary and open industrial network ports designed to link internal rack data directly to supervisory networks without internal subdivision.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3500\/90 125728-01\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.6 x 25.3 x 24 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInternal rack backplane draw (Standard 3500 rack limits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eData Throughput\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 10,000 tags\/sec\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLatency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\u0026lt; 5 ms (EtherNet\/IP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMax Concurrent Clients\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSupported Protocols\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eModicon Modbus, Modbus\/TCP, Proprietary Bently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRelative Humidity\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 to 95% RH (non-condensing)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTransducer Data Integration and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe gateway module samples digitized variables directly from internal processing channels, capturing structural metrics generated by external eddy-current probe scaling configurations. The processing core packages transient values, bypass statuses, and gap voltage validation (-10 VDC targets) data into structured register maps. This provides host controllers with direct records of real-time rotor dynamics while cross-talk suppression registers protect digital registers from phase synchronization noise during multi-channel transfers.\u003c\/p\u003e\n\u003ch3\u003ePacking List\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 3500\/90 125728-01 Communication Gateway Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Factory Installed Backplane Connector Interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRack Installation and Field Interface Guidelines\u003c\/h3\u003e\n\u003ch3\u003eChassis Slot Insertion\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGuide the module circuit card vertically into the assigned monitoring slot of the 3500 system rack chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eApply firm pressure until the backplane connectors seat completely, then secure the front panel retention fasteners.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCommunication Interface Grounding\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute all external Ethernet and serial communication cables using dedicated shielded terminal layouts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the communication cable drain wires are grounded properly at the terminal blocks to prevent ground loops from injecting high-frequency electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Engineering FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the certified maximum data throughput rate for this gateway?\u003c\/p\u003e\n\u003cp\u003eThe internal processing subsystem executes real-time data packaging for up to 10,000 tags\/sec.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping this interface card permitted while the rack is live?\u003c\/p\u003e\n\u003cp\u003eYes, this module supports hot-swap installation inside the 3500 rack frame without disrupting adjacent active monitor loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the latency response time when transmitting data over EtherNet\/IP networks?\u003c\/p\u003e\n\u003cp\u003eThe network stack achieves a continuous physical transfer latency of less than 5 ms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow many external client devices can connect to the port simultaneously?\u003c\/p\u003e\n\u003cp\u003eThe communications processor sustains up to 32 concurrent client connections across active network ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module require standalone power links outside the rack frame?\u003c\/p\u003e\n\u003cp\u003eNo, all required electrical operating potential is derived directly through the internal backplane bus interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are gap voltage validation logs transferred through the register maps?\u003c\/p\u003e\n\u003cp\u003eThe software registers map the digital equivalents of the -10 VDC target signals into accessible Modbus fields.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific protocol variants are natively executed by the module firmware?\u003c\/p\u003e\n\u003cp\u003eThe module executes Modicon Modbus, Modbus\/TCP, and proprietary Bently Nevada communication protocol layers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the exact physical weight and size metrics for shipping manifest records?\u003c\/p\u003e\n\u003cp\u003eThe net mass equals 0.8 kg, and the technical dimensional block measures 2.6 x 25.3 x 24 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026848960685,"sku":"125728-01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/350070m-1_860e80e0-3623-4597-881b-547f8d36cfd9.jpg?v=1782718906","url":"https:\/\/www.maxwellplc.com\/ru\/products\/3500-90-125728-01-bently-nevada-communication-gateway-module-3500-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}