{"product_id":"330930-065-03-05-bently-nevada-cable-extension-3300-series","title":"330930-065-03-05 Bently Nevada Cable Extension 3300 Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330930-065-03-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-065-03-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCable Extension, operates as a dedicated hardware component for signal transmission between proximitor sensors and monitoring instrumentation within TSI (Turbomachinery Information) platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cp\u003eThe part number 330930-065-03-05 specifies a coaxial cable extension assembly designed for impedance-matched coupling. The numerical sequence identifies standard cable length, jacket material, and connector interface configurations compliant with 3300 series transducer system specifications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330930-065-03-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.12 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e18 x 18 x 2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Component\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial Impedance Matched\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM12 X 1 Standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTSI System Interconnection Characteristics\u003c\/h3\u003e\n\u003cp\u003eProper integration of this cable extension requires adherence to total system length (TSL) requirements (e.g., 5m or 9m systems). The cable maintains the 50-ohm characteristic impedance required for eddy-current probe excitation. Signal integrity is contingent upon the preservation of the shield-to-drain connection; improper grounding can introduce noise into the rotor dynamics signal path. In multi-probe installations, cable routing must minimize parallel runs with high-power AC lines to prevent induced common-mode noise.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIndividual 330930-065-03-05 cable extension assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes protective connector dust caps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompliance documentation (CE, UL).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo additional hardware or terminal blocks included.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Maintain electrical continuity of the coaxial shield to the designated proximitor grounding lug.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRouting: Use flexible conduit for mechanical protection; avoid sharp-radius bends that exceed the minimum bend radius of the coaxial core.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection: Ensure M12 X 1 threaded connectors are tightened to manufacturer specifications to maintain IP integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Tie-downs: Secure cables at intervals to mitigate mechanical fatigue from machine-induced vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this cable be used with non-Bently Nevada proximity sensors?\u003c\/p\u003e\n\u003cp\u003eA: Impedance matching is critical for TSI systems. Use with non-standard sensors may alter signal gain and linearity characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How does cable length affect calibration?\u003c\/p\u003e\n\u003cp\u003eA: The 3300 series system is factory calibrated for specific total lengths. Adding this extension requires recalibration of the proximitor to maintain accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the cable jacket chemical resistant?\u003c\/p\u003e\n\u003cp\u003eA: The jacket is rated for standard industrial environments; exposure to aggressive chemical solvents requires additional protective conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum voltage rating?\u003c\/p\u003e\n\u003cp\u003eA: Designed for low-voltage signal transmission (typically \u0026lt; 30 VDC); not intended for power distribution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the connectors be field-terminated?\u003c\/p\u003e\n\u003cp\u003eA: Connector termination requires specialized crimping tools and factory-approved processes to ensure shielding integrity and impedance continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does this cable exhibit signal loss over distance?\u003c\/p\u003e\n\u003cp\u003eA: There is inherent signal attenuation in coaxial cables at high frequencies; this is accounted for within the 5m and 9m calibrated system design.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I verify cable continuity?\u003c\/p\u003e\n\u003cp\u003eA: Use a digital multimeter to verify center conductor continuity and shield resistance-to-ground; ensure no short-circuits exist between conductor and shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are there specific installation torque requirements?\u003c\/p\u003e\n\u003cp\u003eA: Connectors should be hand-tightened or torqued to specific manufacturer values to prevent loosening due to high-frequency machine vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378089517229,"sku":"330930-065-03-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330930-065-03-05-cable-extension-module-dj3putae3wr.jpg?v=1764225490","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330930-065-03-05-bently-nevada-cable-extension-3300-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}