{"product_id":"330930-060-01-05-bently-nevada-3300-nsv-extension-cable","title":"330930-060-01-05 Bently Nevada 3300 NSv Extension Cable","description":"\u003cp\u003eConfigured for signal transmission in 3300 NSv proximity monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330930-060-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330930-060-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable) provides direct physical\/electrical execution for connecting NSv probes to remote Proximitor sensors.\u003c\/p\u003e\n\u003ch3\u003ePart Number Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 330930 extension cable is designed to maintain the impedance matching requirements of the 3300 NSv system. The specific ordering configuration is:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e060\u003c\/strong\u003e: Cable length (6.0 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e01\u003c\/strong\u003e: Connector type (Standard).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Agency approval (Multiple agency approvals).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330930-060-01-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e30 x 30 x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Impedance matched)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial, 75 Ohm nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eThe 330930 cable ensures signal integrity between the NSv probe and the Proximitor. In machinery protection applications, this cable is calibrated as part of the total probe-cable-Proximitor system, where eddy-current probe scaling is maintained across the entire loop. Correct installation is necessary to prevent signal distortion; specifically, the cable must be routed to avoid electromagnetic interference that could affect gap voltage validation (-10 VDC targets). Proper cable management contributes to cross-talk suppression by preventing capacitive coupling between parallel signal loops in the machinery housing.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330930-060-01-05 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 x Connector protective boots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing:\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum bend radius of 25 mm to prevent stress on the coaxial center conductor. Avoid routing near high-current motor leads or VFD cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Seating:\u003c\/p\u003e\n\u003cp\u003eEnsure ClickLoc connectors are fully engaged. A tactile and audible click confirms the mechanical lock and electrical continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding:\u003c\/p\u003e\n\u003cp\u003eThe cable shield must remain isolated from the machine housing unless the specific application design mandates a single-point ground connection at the junction box.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Protection:\u003c\/p\u003e\n\u003cp\u003eUse the provided connector boots to seal interfaces against moisture and oil ingress in the terminal housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan I splice this cable if it is too long?\u003c\/p\u003e\n\u003cp\u003eNo. Splicing or cutting the coaxial cable alters the characteristic impedance, which invalidates the system calibration and accuracy of the rotor dynamics data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this cable compatible with 3300 XL systems?\u003c\/p\u003e\n\u003cp\u003eNo. The 330930 extension cable is specific to the 3300 NSv system and uses different impedance characteristics than the standard 3300 XL cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of excessive cable length?\u003c\/p\u003e\n\u003cp\u003eThe total system length (probe + extension cable) is strictly calibrated. Exceeding specified length limits will cause signal attenuation and calibration errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this cable in high-temperature zones?\u003c\/p\u003e\n\u003cp\u003eThe cable is rated for operation up to +177 deg C. Ensure the routing path does not expose the cable to temperatures exceeding this limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre the connectors waterproof?\u003c\/p\u003e\n\u003cp\u003eThe connectors are designed for industrial use with protective boots. They are not intended for direct immersion in liquid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify a faulty extension cable?\u003c\/p\u003e\n\u003cp\u003eUse a digital multimeter to verify continuity and check for high resistance or shorts between the center conductor and the shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this cable require a specific mounting orientation?\u003c\/p\u003e\n\u003cp\u003eNo, the cable is flexible, but it must be secured using appropriate cable ties to prevent fatigue caused by machine vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 330930 cable agency-rated?\u003c\/p\u003e\n\u003cp\u003eYes, the -05 suffix indicates the cable is qualified for various hazardous area agency approvals. Verify the specific certificate before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518820573357,"sku":"330930-060-01-05","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330930-060-01-05-3300-nsv-extension-cable-l135ebcxad4.jpg?v=1766979523","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330930-060-01-05-bently-nevada-3300-nsv-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}