{"product_id":"330930-060-01-00-bently-nevada-extension-cable-3300-nsv-series","title":"330930-060-01-00 Bently Nevada Extension Cable 3300 NSv Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330930-060-01-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330930-060-01-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable, operates as a dedicated hardware component for signal transmission between proximity probes and oscillators within 3300 NSv transducer systems.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel: 330930-060-01-00\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: 3300 NSv\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration: Suffixes define total cable length, armor protection, and connector termination requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330930-060-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm x 20 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive signal transmission\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCoaxial extension cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 NSv system requires precise eddy-current probe scaling to convert high-frequency displacement signals into linearized voltage outputs. This extension cable maintains the characteristic impedance necessary for radio-frequency transmission between the probe and the oscillator. During installation, gap voltage validation against -10 VDC targets at the oscillator output ensures the probe system remains within its defined linear range. Cross-talk suppression is supported by the cable's shielding properties, which protect the low-level signal from electromagnetic interference, thereby maintaining the integrity of rotor dynamics data in high-density sensor arrays.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330930-060-01-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector protector cap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing: Install the cable through grounded metallic conduit to prevent signal noise; avoid tight bends that exceed the manufacturer's specified minimum bend radius.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Integrity: Verify that coaxial connectors are hand-tightened and free of contaminants to maintain low-impedance electrical contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Ensure the cable shield is continuous and bonded at the appropriate ground point to mitigate electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStrain Relief: Use appropriate cable ties or strain relief hardware to prevent mechanical tension on the connector points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerification: Perform a loop continuity test to ensure there are no shorts or open circuits before finalizing the installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this cable compatible with 3300 XL standard systems?\u003c\/p\u003e\n\u003cp\u003eA: No, the 3300 NSv series extension cables are specifically engineered for the 3300 NSv near-field transducer system and are not interchangeable with standard 3300 XL 8 mm or 11 mm cables.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I shorten or splice this cable in the field?\u003c\/p\u003e\n\u003cp\u003eA: No, the extension cable length is a calibrated part of the transducer system resonance; any modification will invalidate the factory-specified scale factor and measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the armor option?\u003c\/p\u003e\n\u003cp\u003eA: The optional cable armor provides mechanical protection against sharp debris, chemical exposure, and physical wear in demanding industrial equipment skids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the cable require specific grounding?\u003c\/p\u003e\n\u003cp\u003eA: The cable shield should be grounded in accordance with the 3300 NSv installation manual to ensure effective noise rejection and system stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How do I identify if the cable is damaged?\u003c\/p\u003e\n\u003cp\u003eA: Inspect the outer jacket for physical wear and use a multimeter to check for continuity or shorts to ground; an erratic gap voltage signal often indicates a damaged cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the connectors be replaced?\u003c\/p\u003e\n\u003cp\u003eA: Connectors are factory-molded or swaged; they are not intended for field replacement or repair.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the role of the extension cable in the loop?\u003c\/p\u003e\n\u003cp\u003eA: It serves as the transmission path for the radio-frequency excitation signal from the oscillator to the probe and the returned displacement signal to the oscillator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How should connectors be protected during installation?\u003c\/p\u003e\n\u003cp\u003eA: Utilize the supplied connector protector caps until the final connection is made to prevent dirt, moisture, or grease from entering the signal path.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518823063725,"sku":"330930-060-01-00","price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330930-060-01-00-3300-nsv-extension-cable-1foyh1rxycv.jpg?v=1766979611","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330930-060-01-00-bently-nevada-extension-cable-3300-nsv-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}