{"product_id":"330910-06-25-05-11-00-bently-nevada-proximity-probe-3300-nsv","title":"330910-06-25-05-11-00 Bently Nevada Proximity Probe 3300 NSv","description":"\u003cp\u003eConfigured for high-precision displacement sensing in industrial monitoring platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330910-06-25-05-11-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330910\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal transduction of rotor position and vibration within confined mechanical clearances.\u003c\/p\u003e\n\u003ch3\u003eSuffix Designation and Configuration Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 330910-06-25-05-11-00 identifies the following physical and mechanical parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e06: M10 x 1 threaded probe with integrated armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e25: Unthreaded case length of 60 mm and total length of 250 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: 0.5 meter (20 in) integral cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e11: Miniature coaxial ClickLoc connector with connector protector and FluidLoc cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: No special agency approval required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330910-06-25-05-11-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e109 x 2 x 1.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eConsult 3300 NSv system documentation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 x 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMiniature ClickLoc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and TSI Monitoring\u003c\/h3\u003e\n\u003cp\u003eThe 3300 NSv probe is designed specifically for small-diameter shaft monitoring where standard probes lack sufficient dynamic range. Achieving accurate rotor dynamics analysis requires precise eddy-current probe scaling. During setup, users must perform gap voltage validation to target -10 VDC at the Proximitor output, ensuring the system remains within its linear range. Cross-talk suppression is supported by the system's high-frequency carrier design, allowing for close-proximity installation of multiple probes without interference between adjacent channels.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330910-06-25-05-11-00 Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Integrated connector protector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x M10 x 1 mounting nuts (factory installed).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThread the probe into the mounting bracket until the tip reaches the target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBack the probe off to reach the specified gap voltage (-10 VDC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTighten the locknuts to secure the probe against vibration-induced displacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eCabling and Shielding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute the armored cable through conduit to prevent mechanical damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDo not compromise the FluidLoc cable seal at the connector; ensure the connector protector is fully seated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the shield is grounded only at the monitoring rack to avoid ground loop interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the FluidLoc cable?\u003c\/p\u003e\n\u003cp\u003eFluidLoc cable is designed to prevent oil or other process fluids from migrating through the cable assembly, protecting the sensor electronics from contamination.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used for high-temperature applications?\u003c\/p\u003e\n\u003cp\u003eConsult the 3300 NSv system technical manual for specific temperature ratings; using the probe beyond rated limits will degrade accuracy and service life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the probe M10 threaded?\u003c\/p\u003e\n\u003cp\u003eThe M10 x 1 thread is selected for compact installation in equipment where standard 3\/8-24 or 1\/2-20 threads are physically too large for the mounting site.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I verify the gap voltage?\u003c\/p\u003e\n\u003cp\u003eConnect a high-impedance digital voltmeter to the output terminals of the corresponding Proximitor sensor and adjust the probe until the target -10 VDC is observed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the connector interchangeable with standard probes?\u003c\/p\u003e\n\u003cp\u003eNo, the 3300 NSv uses a miniature coaxial ClickLoc connector, which is not physically compatible with standard 3300 XL probe connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the armor is bent too tightly?\u003c\/p\u003e\n\u003cp\u003eExcessive bending can cause internal deformation of the coaxial cable, changing its characteristic impedance and resulting in signal distortion or loss.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I shorten the integral cable?\u003c\/p\u003e\n\u003cp\u003eNo, the system is calibrated as a matched set (probe + cable + Proximitor). Shortening the cable will alter the system response and render calibration invalid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require a specific Proximitor model?\u003c\/p\u003e\n\u003cp\u003eYes, it must be paired with a 3300 NSv Proximitor sensor specifically calibrated for the 3300 NSv probe frequency and impedance characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026830676141,"sku":"330910-06-25-05-11-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--2_0c76a35b-c6fe-4c95-b36c-e9dbd824adc7.jpg?v=1782787675","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330910-06-25-05-11-00-bently-nevada-proximity-probe-3300-nsv","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}