{"product_id":"330909-00-80-10-02-05-bently-nevada-3300-xl-proximity-probe-cable","title":"330909-00-80-10-02-05 Bently Nevada 3300 XL Proximity Probe Cable","description":"\u003cp\u003eConfigured for high-frequency signal transmission in 3300 XL 8mm Proximity Transducer Systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330909-00-80-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330909-00-80-10-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe Cable) provides direct electrical connectivity between the proximity probe and the Proximitor sensor. This component maintains the required characteristic impedance for signal propagation and mechanical gap measurement.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Reference\u003c\/h3\u003e\n\u003cp\u003eThe 330909-00-80-10-02-05 identifies a specific cable assembly length and construction standard within the 3300 XL 8mm system. The part number denotes a fixed-length coaxial configuration calibrated for specified loop resistance. Modifications to the physical length or shielding configuration of this assembly are not permitted, as such changes affect the transducer system's calibrated output voltage per unit of displacement.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330909-00-80-10-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.16 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e116.0 x 1.6 x 1.6 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40 deg C to +70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Component\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtection Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP67\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHS Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eBently Nevada TSI Mechanical Monitoring Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe probe cable is a passive impedance-matching component integral to the eddy-current probe scaling process. It maintains the signal path integrity required for -10 VDC gap voltage validation at the Proximitor. The coaxial construction is optimized to minimize signal attenuation and cross-talk suppression in proximity-based shaft monitoring. When integrated into the 3300 XL architecture, the cable ensures the linearity of the transducer system across the full range of rotor dynamics, preventing phase shifts that could compromise vibration analysis.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCable assembly includes the 330909-00-80-10-02-05 unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct is provided in a sealed package.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo additional hardware or installation kits are included with the cable assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration certificates are generated upon factory order validation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain the manufacturer-specified minimum bend radius to prevent stress on the internal coaxial center conductor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the cable using non-metallic clamps to prevent contact-induced signal interference or mechanical fatigue.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure connector mating surfaces are cleaned with an appropriate electronic contact cleaner prior to coupling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTorque the connection to the specified value; excessive force may damage the connector threads or the internal sealing O-ring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUtilize dedicated instrument cable trays to prevent electrical noise coupling from power conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of cable length on system calibration?\u003c\/p\u003e\n\u003cp\u003eThe cable length is part of the system impedance; changing the length without re-calibrating the Proximitor will result in significant measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be spliced if damaged?\u003c\/p\u003e\n\u003cp\u003eSplicing is not recommended. Any physical alteration to the coaxial cable changes the impedance, rendering the transducer system invalid.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the IP67 rating maintained?\u003c\/p\u003e\n\u003cp\u003eThe rating is maintained by the integrated rubber seals and the secure engagement of the threaded coaxial connectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of signal does this cable carry?\u003c\/p\u003e\n\u003cp\u003eThe cable carries high-frequency radio signals generated by the Proximitor sensor to the probe tip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre there specific grounding requirements?\u003c\/p\u003e\n\u003cp\u003eThe cable shield should be grounded only at the specified system ground point to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this cable require specific shielding?\u003c\/p\u003e\n\u003cp\u003eThe cable is inherently shielded by its coaxial construction, which is required for operation in high-EMI environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat should be done if the connector threads are worn?\u003c\/p\u003e\n\u003cp\u003eWorn connectors should be replaced immediately, as they cannot guarantee the physical contact required for low-impedance signal transmission.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify if the cable is degraded?\u003c\/p\u003e\n\u003cp\u003eDegradation is typically identified by an unstable gap voltage or an intermittent \"Transducer Fault\" status in the monitoring rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45378088140973,"sku":"330909-00-80-10-02-05","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330909-00-80-10-02-05-sensor-proximity-probe-cable-via-fedex-pmvvusodgop.jpg?v=1764225475","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330909-00-80-10-02-05-bently-nevada-3300-xl-proximity-probe-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}