{"product_id":"330905-00-08-10-02-05-bently-nevada-3300-nsv-series-proximity-probes","title":"330905-00-08-10-02-05 Bently Nevada 3300 NSv Series Proximity Probes","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330905-00-08-10-02-05\u003c\/strong\u003e operates as a dedicated hardware component for non-contacting displacement and vibration measurements within \u003cstrong\u003e330905\u003c\/strong\u003e Proximity Probes platforms. Designed for small-profile installation requirements, the device converts raw proximity gaps into proportional high-frequency eddy-current impedance shifts to execute continuous monitoring of rotating machinery shafts.\u003c\/p\u003e\n\u003ch3\u003eOption Selection Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330905: Base model catalog identifier for the 3300 NSv proximity probe transducer.\u003c\/li\u003e\n\u003cli\u003e00: Unthreaded case length option specifying 0 mm of smooth cylindrical body.\u003c\/li\u003e\n\u003cli\u003e08: Fully threaded case length configuration assigning an 80 mm metric housing.\u003c\/li\u003e\n\u003cli\u003e10: Total length option specifying a 1.0 meter (39 in) integrated standard cable.\u003c\/li\u003e\n\u003cli\u003e02: Connector type option selecting a miniature coaxial ClickLoc connector layout.\u003c\/li\u003e\n\u003cli\u003e05: Agency approval option specifying standard manufacturing certification matrix.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstrument Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330905-00-08-10-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Thread Geometry\u003c\/td\u003e\n\u003ctd\u003eM10 x 1 metric thread\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Length Profile\u003c\/td\u003e\n\u003ctd\u003e80 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegral Cable Span\u003c\/td\u003e\n\u003ctd\u003e1.0 meter (39 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Termination\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArmor Variant\u003c\/td\u003e\n\u003ctd\u003eWithout armor, standard coaxial insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensor architecture driven by external high-frequency RF excitation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e20.3 cm x 22.0 cm x 3.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Linearization \u0026amp; Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe compact configuration of the 3300 NSv probe modifies the standard eddy-current probe scaling variables to maintain high resolution over tight spatial measurements. Validating the loop operation requires structured field gap voltage validation routines, checking for standard -10 VDC targets reference output across the calibrated scale window. The internal sub-millimeter coil accurately captures transient rotor dynamics movements while the optimized shield architecture preserves required cross-talk suppression safety factors during adjacent multi-probe deployment.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330905-00-08-10-02-05 Proximity Probe Unit\u003c\/li\u003e\n\u003cli\u003e1 x ClickLoc Connector Protective Insulator Sleeve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Integration \u0026amp; Signal Shielding\u003c\/h3\u003e\n\u003ch4\u003eCasing Insertion and Depth Calibration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThread the M10 x 1 housing through the bracket assembly, confirming smooth mechanical alignment along the full 80 mm threaded body.\u003c\/li\u003e\n\u003cli\u003eAdjust the insertion clearance until the static volt reading on the test instrument confirms the target mid-scale position before locking down the hardware hex nuts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCoaxial Line Distribution and Earthing\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eRoute the unarmored 1.0 meter lead wire through rigid channel runs, separating the low-voltage sensor lines from power distribution tracks.\u003c\/li\u003e\n\u003cli\u003eTerminate the secondary external shield braid at the single monitoring rack common terminal, maintaining absolute isolation at the machinery frame end to eliminate loop errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swap manipulation of the miniature ClickLoc connection permitted on live monitoring circuits?\u003c\/p\u003e\n\u003cp\u003eYes, the electrical design supports hot-swap changes of the coaxial terminal without causing hardware degradation or damage to the instrumentation rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the NSv footprint influence the calibrated eddy-current probe scaling?\u003c\/p\u003e\n\u003cp\u003eThe small tip geometry restricts the magnetic field distribution, which generates a steeper calibration slope than standard 8 mm sensor elements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific failure occurs if the field gap voltage validation deviates significantly from the target -10 VDC center?\u003c\/p\u003e\n\u003cp\u003eDeviations shift the active target point outside the linear monitoring window, causing signal clipping during high-amplitude shaft vibration events.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the 1.0 meter standard cable be modified or spliced directly in the industrial field environment?\u003c\/p\u003e\n\u003cp\u003eNo, cutting or splicing the integrated wire changes the total loop impedance parameters and permanently corruptens system tracking calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat criteria determines cross-talk suppression limits between adjacent M10 sensor tips?\u003c\/p\u003e\n\u003cp\u003ePhysical side-by-side spacing determines field overlap; probes must maintain specified mechanical separation to suppress loop cross-talk.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the thermal degradation threshold for the unarmored standard cable assembly?\u003c\/p\u003e\n\u003cp\u003eThe structural materials and fluoropolymer insulation maintain physical parameters up to a maximum operating limit of +177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an active DC power loop applied directly to the internal circuitry of this probe model?\u003c\/p\u003e\n\u003cp\u003eNo, this component functions as a passive inductive element that requires high-frequency RF drive parameters from the matched Proximitor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat mechanical failure occurs if the housing is installed with fewer than 5 full threads of engagement?\u003c\/p\u003e\n\u003cp\u003eLow thread engagement increases stress under severe machinery vibration, leading to loose mounting threads or failure of the probe tip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026752458925,"sku":"330905-00-08-10-02-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian10_cb456e8c-c28a-4aec-ad63-24186981e49f.jpg?v=1783674062","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330905-00-08-10-02-05-bently-nevada-3300-nsv-series-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}