{"product_id":"330905-00-05-10-12-cn-bently-nevada-3300-nsv-proximity-probe","title":"330905-00-05-10-12-CN Bently Nevada 3300 NSv Proximity Probe","description":"\u003cp\u003eConfigured for high-precision displacement sensing in compact mechanical envelopes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330905-00-05-10-12-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330905\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal transduction of rotor position and vibration within confined radial clearances.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Configuration\u003c\/h3\u003e\n\u003cp\u003eThe 330905-00-05-10-12-CN identifies the following physical and mechanical parameters:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e00: M10 x 1 threaded probe, without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Minimum unthreaded length of 0 mm and minimum case length of 50 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: 1.0 meter (39 in) integral cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12: Miniature coaxial ClickLoc connector with FluidLoc cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCN: CSA, ATEX, and IECEx agency approval rating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330905-00-05-10-12-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.3 x 22 x 3.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-52 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 x 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc Coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eThe 3300 NSv system is optimized for small-diameter shafts where standard probe geometry is physically incompatible. Accurate rotor dynamics analysis depends on precise eddy-current probe scaling to ensure linear output. During installation, users must conduct gap voltage validation to target -10 VDC at the Proximitor output, which establishes the required reference for linear operation. The integrated FluidLoc cable design effectively prevents oil or other process fluid migration through the cable assembly, while advanced cross-talk suppression ensures signal clarity when multiple sensors are installed in close proximity.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330905-00-05-10-12-CN Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation hardware kit (mounting nuts included).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Regulatory compliance documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThread the probe into the mounting hole until the target gap is reached.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the gap until the Proximitor output reaches the nominal -10 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the probe position with the provided locknuts to prevent vibration-induced movement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the FluidLoc cable is not kinked or subjected to sharp bends during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the ClickLoc miniature coaxial connector securely, ensuring a firm audible click.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround the cable shield only at the monitoring rack to avoid ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the FluidLoc cable?\u003c\/p\u003e\n\u003cp\u003eFluidLoc cable incorporates a specialized seal that prevents process fluids, such as oil or water, from traveling through the internal cable structure to the probe connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eThe CN suffix indicates the probe has obtained CSA, ATEX, and IECEx approvals for safe operation in specified hazardous area environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the significance of the 3300 NSv platform?\u003c\/p\u003e\n\u003cp\u003eThe NSv (Non-Standard velocity) platform is specifically designed for small-diameter shafts and limited-space applications where standard Bently Nevada 3300 probes cannot fit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I verify signal integrity?\u003c\/p\u003e\n\u003cp\u003eVerify integrity by monitoring the gap voltage at the Proximitor sensor output and ensuring the signal remains stable and within the expected range for the given gap distance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe field-repairable?\u003c\/p\u003e\n\u003cp\u003eNo, the transducer assembly is a factory-calibrated, sealed unit. Any attempt to repair the probe or cable assembly will void calibration and system accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I shorten the 1.0 meter integral cable?\u003c\/p\u003e\n\u003cp\u003eNo, the system is calibrated as a matched set. Altering the cable length changes the electrical characteristics of the loop and invalidates the system calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the thermal operating range?\u003c\/p\u003e\n\u003cp\u003eThe probe is rated for extreme environments, from -52 deg C up to +177 deg C, suitable for most high-temperature machinery housings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require a specific Proximitor?\u003c\/p\u003e\n\u003cp\u003eYes, it must be paired with an NSv-compatible Proximitor, as standard Proximitor units are calibrated for different transducer resonant frequencies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026810065069,"sku":"330905-00-05-10-12-CN","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian--1_4c13eca9-294f-4035-bfe7-493aa9c614d6.jpg?v=1782790878","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330905-00-05-10-12-cn-bently-nevada-3300-nsv-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}