{"product_id":"330903-00-11-05-02-05-bently-nevada-3300-xl-nsv-proximity-probe","title":"330903-00-11-05-02-05 Bently Nevada 3300 XL NSv Proximity Probe","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330903-00-11-05-02-05\u003c\/strong\u003e serves as the primary \u003cstrong\u003e330903\u003c\/strong\u003e Proximity Probe utilized to execute non-contacting shaft displacement and vibration measurements across 3300 XL NSv platforms.\u003c\/p\u003e\n\u003ch3\u003ePhysical Code and Option Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330903\u003c\/strong\u003e: Core model nomenclature for the 3300 NSv proximity probe mechanical housing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e: Defines a 0 mm unthreaded sleeve option profile.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e11\u003c\/strong\u003e: Allocates a 110 mm overall case length configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: Establishes a 0.5 meter (20 in) hardware cable length parameter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02\u003c\/strong\u003e: Equips a miniature coaxial ClickLoc connector on a standard unarmored cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05\u003c\/strong\u003e: Authorizes full multiple agency approvals certifications for hazardous environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Performance Indexes\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330903-00-11-05-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.06 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e62 x 1 x 1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +177 deg C mechanical tip rating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensor driven via high-frequency RF signal from Proximitor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Specification\u003c\/td\u003e\n\u003ctd\u003eM8x1 metric pitch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd\u003e0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Length\u003c\/td\u003e\n\u003ctd\u003e110 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Cable Length\u003c\/td\u003e\n\u003ctd\u003e0.5 meter (20 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterconnect Type\u003c\/td\u003e\n\u003ctd\u003eMiniature coaxial ClickLoc connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSignal Scaling and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe hardware relies on a localized eddy-current probe scaling format optimized for narrow magnetic fields near surrounding metal steps. When tracking target areas with limited side clearance, the electronic assembly provides cross-talk suppression between adjacent channels while returning a steady volt-to-mil scale output across the full rotor dynamics measurement band.\u003c\/p\u003e\n\u003ch3\u003eLogistics Packaging Bill\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 330903-00-11-05-02-05 3300 XL NSv Proximity Probe\u003c\/li\u003e\n\u003cli\u003e1 x Coaxial Connector Protection Sleeve Kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Protocols and Mechanical Limits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread Insertion \u0026amp; Locking\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eAdvance the M8x1 threaded barrel into the sensor port slowly until reaching the proper clearance target.\u003c\/li\u003e\n\u003cli\u003eKeep a minimum of 5 full thread engagements inside the mounting boss to withstand machine oscillation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCoaxial Routing Restrictions\u003c\/strong\u003e\n\u003cul\u003e\n\u003cli\u003eRoute the 0.5 meter unarmored cable away from raw high-voltage motor supply conductors.\u003c\/li\u003e\n\u003cli\u003eMaintain a minimum cable bending radius of 25.4 mm (1.0 in) along all physical support clamps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Interface FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWhat standard gap voltage validation target is required during baseline field calibration?\u003c\/p\u003e\n\u003cp\u003eThe proximity loop relies on standard gap voltage validation targeting a nominal -10 VDC output position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this specific miniature ClickLoc connector be mated directly without specialized tools?\u003c\/p\u003e\n\u003cp\u003eYes, the ClickLoc interconnect snaps and locks manually into the extension cable line without custom mechanical wrenches.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the 0 mm unthreaded length option affect physical sensor depth adjustment routines?\u003c\/p\u003e\n\u003cp\u003eThe full 110 mm barrel is threaded, allowing adjustable positioning inside deep machine cases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat action occurs if moisture enters the miniature coaxial connector terminal junction?\u003c\/p\u003e\n\u003cp\u003eMoisture changes line impedance, degrading eddy-current probe scaling accuracy and generating false error signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs external cooling required when operating the sensor tip near high-temperature journal bearings?\u003c\/p\u003e\n\u003cp\u003eNo, the passive transducer elements safely operate up to +177 deg C under normal convection conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this NSv series transducer be mixed with standard 3300 XL 8 mm Proximitor units?\u003c\/p\u003e\n\u003cp\u003eNo, the NSv series possesses specific tuning and must use dedicated matching NSv Proximitor components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the flexible coaxial cable shielded from localized electromagnetic interference fields?\u003c\/p\u003e\n\u003cp\u003eThe integrated outer braid shield isolates internal loop signals and must connect to instrument ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the consequence of exceeding the maximum torque specifications on the M8 barrel?\u003c\/p\u003e\n\u003cp\u003eOver-torquing deforms the internal internal wire paths, causing permanent failure of the sensing tip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026672636077,"sku":"330903-00-11-05-02-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian10_1b8965fd-527a-44c8-8a94-ba96d3021270.jpg?v=1783674678","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330903-00-11-05-02-05-bently-nevada-3300-xl-nsv-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}