{"product_id":"330851-06-000-070-50-00-05-bently-nevada-proximity-probe-3300-xl-nsv","title":"330851-06-000-070-50-00-05 Bently Nevada Proximity Probe 3300 XL NSv","description":"\u003cp\u003eThe Bently Nevada 330851-06-000-070-50-00-05 serves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330851\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe utilized to execute non-contacting shaft displacement and vibration measurements across 3300 XL NSv platforms.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Matrix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330851: 3300 XL NSv Proximity Probe, 3\/8-24 UNF thread\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-06: 0.6 inch unthreaded length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-000: 0.0 inch overall case length option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-070: 7.0 inches total length option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-50: FluidLoc cable option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-00: Miniature coaxial ClickLoc connector option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e-05: Multiple hazardous area agency approvals option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Parameter Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330851-06-000-070-50-00-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.32 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.0 x 15.0 x 4.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to 177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive Element (Driven by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Linear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.52 mm (60 mils) nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluidLoc structure\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInterface Connector\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc miniature coaxial connector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMachinery Monitoring and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThis proximity sensor operates on the eddy-current principle to track dynamic shaft behavior and rotor dynamics. The mechanical assembly converts distance parameters into high-frequency RF fields generated by the Proximitor. Field calibration relies on accurate gap voltage validation, targeting a nominal -10 VDC center-scale checkpoint for optimal linearity. Precision tip architecture provides stable eddy-current probe scaling metrics while suppressing multi-channel cross-talk in dense radial setups.\u003c\/p\u003e\n\u003ch3\u003eLogistics Packaging Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330851-06-000-070-50-00-05 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 3\/8-24 Brass Hex Mounting Locknuts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Coaxial Connector Silicone Protection Boot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Mechanical Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThread Engagement Stability\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnsure bracket mounting achieves rigid thread engagement to eliminate case vibration harmonics that distort true target readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGap Voltage Position Adjustment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAdjust the mechanical insertion depth until gap voltage validation registers approximately -10 VDC at the monitor rack test points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClearance Isolation Proportions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintain an open cylindrical radius of at least 15 mm around the probe tip to prevent target anomalies from surrounding metal walls.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCoaxial Coupling Connection\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eHand-tighten the ClickLoc miniature coaxial connector; do not use pliers or mechanical tools to avoid crushing internal pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransducer System FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this proximity probe configuration support hot-swap terminal substitution?\u003c\/p\u003e\n\u003cp\u003eYes. The probe can be physically disconnected from the extension cable while the main Proximitor and monitor rack remain energized.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does structural surface finish affect eddy-current probe scaling?\u003c\/p\u003e\n\u003cp\u003eSurface defects or microstructural variations modify electrical conductivity, altering the calibrated linear scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical symptom indicates a failure in gap voltage validation?\u003c\/p\u003e\n\u003cp\u003eA validation reading sitting near 0 VDC or exceeding -18 VDC indicates an open circuit, short circuit, or incorrect mechanical gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this model operate with any length of extension cable?\u003c\/p\u003e\n\u003cp\u003eNo. The probe must match the specific system configuration loop length to preserve factory calibration tolerances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is cross-talk suppression managed when installing two orthogonal probes?\u003c\/p\u003e\n\u003cp\u003eMaintain a minimum axial separation of 40 mm between probe tips when monitoring identical shaft sections to prevent RF interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the thermal operating limit of the tip material?\u003c\/p\u003e\n\u003cp\u003eThe specialized sensor tip holds structural and electrical integrity during continuous thermal exposure up to 177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external isolation barrier required for hazardous area installations?\u003c\/p\u003e\n\u003cp\u003eYes. Intrinsic safety barriers must be wired between the Proximitor sensor loop and the monitoring system rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat occurs if the coaxial connector boot is omitted in humid conditions?\u003c\/p\u003e\n\u003cp\u003eMoisture ingress increases electrical leakage resistance, causing calibration drift and intermittent channel fault alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518807859373,"sku":"330851-06-000-070-50-00-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330851-06-000-070-50-00-05-proximity-probe-pfqpq5wantv.jpg?v=1766979370","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330851-06-000-070-50-00-05-bently-nevada-proximity-probe-3300-xl-nsv","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}