{"product_id":"330703-000-060-10-01-00-bently-nevada-3300-xl-series-proximity-probes","title":"330703-000-060-10-01-00 Bently Nevada 3300 XL Series Proximity Probes","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330703-000-060-10-01-00\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330703\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes, operates as a dedicated hardware component for non-contacting static and dynamic displacement measurements within 3300 XL 11 mm Proximity Transducer platforms. The hardware decodes target position variables by evaluating changes in the magnetic field generated at the probe tip, outputting real-time analog displacement parameters directly to monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering Options Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330703: Catalog prefix indicating the 3300 XL 11 mm probe hardware assembly with M14 x 1.5 thread.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e000: Unthreaded length designation choosing 0 mm of smooth sensor barrel length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e060: Overall case length designation selecting 60 mm of total threaded case housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Total length option denoting a 1.0 meter (3.3 feet) integrated lead cable length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e01: Cable construction code for standard wire with a miniature coaxial ClickLoc connector and connector protector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency approval option establishing that hazardous area approval certificates are not required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; height: 273.984px;\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\" style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cspan\u003e330703-000-060-10-01-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cspan\u003eProximity Probes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cspan\u003eTransducer Tip Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cspan\u003e11 mm diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cspan\u003eThreat Profile\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cspan\u003eM14 x 1.5 thread, without armor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cspan\u003eCable Assembly\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cspan\u003e1.0 meter (3.3 feet) standard cable\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cspan\u003eConnector Configuration\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cspan\u003eMiniature coaxial ClickLoc with protector\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cspan\u003e-35 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cspan\u003ePassive physical sensor driven by external Proximitor driver\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cspan\u003e116.0 cm x 2.5 cm x 2.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5703px;\"\u003e\n\u003ctd style=\"width: 28.8002%; height: 19.5703px;\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 68.0409%; height: 19.5703px;\"\u003e\u003cspan\u003e0.8 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThis 11 mm sensor configuration relies on exact eddy-current probe scaling protocols designed to track industrial machinery rotor dynamics. Field-level gap voltage validation routines are verified during physical installation to calibrate the sensing centerpoint against -10 VDC targets. Integrated structural layout parameters yield an effective cross-talk suppression rating that minimizes electromagnetic field interactions when multiple probes run in close proximity within a single fluid-film bearing housing.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330703-000-060-10-01-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 ClickLoc Coaxial Connector Protector Shell\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Threading and Bracket Alignment\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInsert the M14 x 1.5 threaded probe barrel through the indicator bracket housing and ensure a minimum of 5 full threads engagement before tightening the locknuts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the insertion clearance while checking the live DC circuit output voltage until the target resting gap voltage parameter is obtained.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eField Signal Protection and Cable Anchoring\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the 1.0 meter standard cable along the machinery casing using insulated tie clamps to prevent physical vibration wear on the outer jacket.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute all coaxial signal leads inside dedicated steel conduit runs to safeguard low-level voltage data streams from ambient interference sources.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs live hot-swap replacement supported for this probe while the monitoring system is under power?\u003c\/p\u003e\n\u003cp\u003eYes, the analog probe assembly can be connected or disconnected from the active Proximitor loop without introducing voltage faults across adjacent monitor channels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the field gap voltage validation verified during sensor installation?\u003c\/p\u003e\n\u003cp\u003eTechnicians measure the raw negative DC potential across the extension line using a digital multimeter until the target -10 VDC baseline indicator is reached.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical parameters dictate the linear output of the eddy-current probe scaling?\u003c\/p\u003e\n\u003cp\u003eThe 11 mm tip face diameter defines the overall magnetic path volume, establishing the specific measuring zone range and scale slope.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this proximity sensor run directly into a DCS analog input card without a driver?\u003c\/p\u003e\n\u003cp\u003eNo, this component functions as a passive inductor and requires a matching 3300 XL Proximitor demodulator to convert impedance variations into a linear voltage signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat step prevents cross-talk suppression failures when two 11 mm probes cross paths?\u003c\/p\u003e\n\u003cp\u003eProbes must maintain the standard mechanical spacing limits specified in the system design manual to prevent the high-frequency field envelopes from bleeding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the factory-installed ClickLoc connector protector option?\u003c\/p\u003e\n\u003cp\u003eThe protector provides an environmental shield around the miniature coaxial junction, locking out oil mist, moisture, and debris from the signal pins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the lack of flexible metal armor alter the temperature rating of the cable insulation?\u003c\/p\u003e\n\u003cp\u003eNo, the non-armored cable retains the full factory operational threshold up to +177 deg C but requires additional external structural routing support.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the shielding braid be managed for this proximity probe setup?\u003c\/p\u003e\n\u003cp\u003eThe inner coaxial shield must be maintained continuously through the extension loop and grounded solely at the Proximitor panel ground terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026756292781,"sku":"330703-000-060-10-01-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian-55_23c0eb63-27f6-4298-86e2-0b09b1303752.jpg?v=1783783807","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330703-000-060-10-01-00-bently-nevada-3300-xl-series-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}