{"product_id":"330192-00-20-10-00-bently-nevada-3300-xl-series-proximity-probe","title":"330192-00-20-10-00 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330192-00-20-10-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e330192\u003c\/strong\u003e Proximity Probe, operates as a dedicated hardware component for non-contacting shaft vibration and axial position measurement within 3300 XL platforms. The component executes sub-micron eddy-current detection against rotating target tracks, transforming physical displacement into dynamic high-frequency electrical signals processed by a matching Proximitor sensor.\u003c\/p\u003e\n\u003ch3\u003eModel Number Nomenclature Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330192\u003c\/strong\u003e: Base model indicator for the 3300 XL 8 mm Extended Temperature Range (ETR) proximity probe with 3\/8-24 UNF thread and stainless steel armor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e: Unthreaded Length Option specifying 0.0 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-20\u003c\/strong\u003e: Overall Case Length Option specifying 2.0 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-10\u003c\/strong\u003e: Total Length Option designating 1.0 meter (3.3 feet) of armored lead cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e: Agency Approval Option acquiring no regulatory certifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectromechanical Parameters\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330192-00-20-10-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e1.8 x 1.6 x 110.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eExtended temperature rating up to +260 deg C for probe tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive transducer loop device powered via Proximitor drive voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Tip Diameter\u003c\/td\u003e\n\u003ctd\u003e8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThread Specification\u003c\/td\u003e\n\u003ctd\u003e3\/8-24 UNF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhysical Interface\u003c\/td\u003e\n\u003ctd\u003eGold-Plated ClickLoc coaxial connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Insulation Material\u003c\/td\u003e\n\u003ctd\u003eHigh-Performance Polyphenylene Sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Rotor Dynamics Validation\u003c\/h3\u003e\n\u003cp\u003eThe 330192-00-20-10-00 probe generates an alternating magnetic field from its internal copper wire coil encased in the high-performance PPS tip. Mismatches or mechanical shifts in target placement change the eddy-current probe scaling, directly disrupting the stability of the system. Technicians apply gap voltage validation measurements targeting a baseline of -10 VDC to position the sensor correctly within the linear range. Maintaining this precise spatial tracking enables error-free assessment of high-frequency rotor dynamics and cross-talk suppression between adjacent sensor nodes.\u003c\/p\u003e\n\u003ch3\u003ePackage Manifest\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 330192-00-20-10-00 Armored Proximity Probe\u003c\/li\u003e\n\u003cli\u003e2 x Thread Alignment Washers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Integration Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Air Gap Calibration\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSet the physical physical distance between the sensor tip face and the shaft target track to exactly 1.27 mm (50 mils) to reach the linear operational window.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTorque Application Boundaries\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTighten the 3\/8-24 threaded body to a standard value of 68 N m (50 ft lb), never exceeding the structural threshold of 163 N m (120 ft lb).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRadial Metal Clearance Zone\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintain a clear continuous radius of less than 16.0 mm (0.63 in) of open space around the probe tip to completely isolate the signal path from side-viewing interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArmored Cable Routing Limits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eLayout the flexible stainless steel armor layer ensuring that all turns maintain a minimum bend radius of 25.4 mm (1.0 in) to prevent internal core kinks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Support Inquiries\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCan this proximity probe be modified in the field by shortening the physical armored cable length?\u003c\/p\u003e\n\u003cp\u003eNo. The electrical characteristics of the 1.0 meter cable are factory-matched to maintain precise eddy-current probe scaling, and cutting the cable destroys system calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the standard diagnostic procedure if the loop fails to establish the required gap voltage validation?\u003c\/p\u003e\n\u003cp\u003eCheck the physical distance between the tip and target track using feeler gauges to confirm it is within the 1.27 mm limit, and inspect the gold ClickLoc contact points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this ETR hardware variant support live hot-swap replacement on a fully powered monitoring rack system?\u003c\/p\u003e\n\u003cp\u003eYes, the passive probe can be physically uncoupled and reconnected while the monitor is powered, though this action will trigger a temporary channel fault indication.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the polyphenylene sulfide tip material handle long-term exposure to hot synthetic lubricants?\u003c\/p\u003e\n\u003cp\u003eThe PPS compound is chemically inert and withstands high-temperature industrial fluids without structural degradation, swelling, or changes to dielectric constants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical symptom indicates that the armored lead cable has bent past its minimum limits?\u003c\/p\u003e\n\u003cp\u003eThe monitor system will register high-frequency noise spikes or erratic intermittent voltage shifts due to fractures within the internal coaxial insulation layers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the lack of agency approvals on this specific configuration limit its electrical installation parameters?\u003c\/p\u003e\n\u003cp\u003eYes, this non-approved variant cannot be routed directly into certified hazardous areas without utilizing isolated intrinsic safety barriers or explosion-proof enclosures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow can side-viewing interference from adjacent structural housing components be prevented during mounting?\u003c\/p\u003e\n\u003cp\u003eEnsure the 16.0 mm radial clearance area around the tip is free of non-target metals by adjusting the unthreaded depth or using a counterbored mount hole.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat electrical test confirms that the internal copper induction coil has shorted out or opened?\u003c\/p\u003e\n\u003cp\u003eDisconnect the ClickLoc fitting and measure the DC resistance across the center pin and outer shield using a digital multimeter to check for an open circuit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025805627565,"sku":"330192-00-20-10-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xianxian_98_cbc3dde0-88bf-4771-a9ee-f7429fd18844.jpg?v=1783679091","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330192-00-20-10-00-bently-nevada-3300-xl-series-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}