{"product_id":"330173-00-03-10-02-00-bently-nevada-3300-5mm-proximity-probes-3300-series","title":"330173-00-03-10-02-00 Bently Nevada 3300 5mm Proximity Probes 3300 Series","description":"\u003cp\u003eConfigured for non-contact shaft position and vibration monitoring in industrial machinery, the \u003cstrong\u003eBently Nevada 330173-00-03-10-02-00\u003c\/strong\u003e (\u003cstrong\u003e330173\u003c\/strong\u003e 3300 5mm Proximity Probes) provides direct physical signal transduction for turbine monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Suffix Mapping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e330173: Base model designation for 3300 5mm proximity probes.\u003c\/li\u003e\n\u003cli\u003e00: Unthreaded length defined as 0.0 mm.\u003c\/li\u003e\n\u003cli\u003e03: Overall case length defined as 30 mm.\u003c\/li\u003e\n\u003cli\u003e10: Total system cable length of 1.0 meter.\u003c\/li\u003e\n\u003cli\u003e02: Miniature coaxial ClickLoc connector with standard cable type.\u003c\/li\u003e\n\u003cli\u003e00: Standard configuration with no additional agency approval requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330173-00-03-10-02-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e115.5 x 1.5 x 1.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-51 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive sensor (powered by Proximitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Diameter\u003c\/td\u003e\n\u003ctd\u003e5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Thread\u003c\/td\u003e\n\u003ctd\u003eM8 x 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMechanical Monitoring and TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThis probe utilizes eddy-current transducer scaling to measure distance between the sensor tip and the conductive target. The system operates on a linear range defined by the target material, typically requiring a gap voltage validation target of -10 VDC when measured at the center of the linear span. Rotor dynamics analysis relies on the high-frequency response of this probe to detect vibration vectors. To ensure signal integrity, cross-talk suppression is maintained by utilizing shielded coaxial cabling, preventing electromagnetic interference from contaminating the radial vibration or thrust position signals processed by the monitoring modules.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e1 x 330173-00-03-10-02-00 Proximity Probe\u003c\/li\u003e\n\u003cli\u003e2 x M8 x 1 lock nuts for mounting\u003c\/li\u003e\n\u003cli\u003e1 x Thread seal washer\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGap Setting: Use a feeler gauge to establish the cold-gap required for the specific machinery application.\u003c\/li\u003e\n\u003cli\u003eGrounding: Terminate cable shielding at the Proximitor sensor end to minimize ground loops.\u003c\/li\u003e\n\u003cli\u003eBending Radius: Maintain a minimum bend radius of 25 mm for the miniature coaxial cable to prevent impedance shifts.\u003c\/li\u003e\n\u003cli\u003eThread Engagement: Ensure full engagement of the M8 x 1 thread into the mounting bracket to prevent mechanical resonance.\u003c\/li\u003e\n\u003cli\u003eConnector Integrity: Ensure the ClickLoc connector is fully seated and clicked to maintain environmental sealing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this probe be used for high-temperature applications?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the probe tip is rated for continuous operation up to 177 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the cable length affect the system calibration?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the total length of 1.0 meter is integrated into the system impedance and must not be altered in the field.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this probe compatible with older 3300 monitoring systems?\u003c\/p\u003e\n\u003cp\u003eA: The 3300 5mm probe is designed for compatibility with standard 3300 series Proximitor sensors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the effect of changing the target material?\u003c\/p\u003e\n\u003cp\u003eA: Changing the target material from 4140 steel will significantly alter the probe scaling and linearity, requiring recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is the ClickLoc connector preferred?\u003c\/p\u003e\n\u003cp\u003eA: The ClickLoc connector ensures a vibration-proof mechanical connection that prevents intermittent electrical contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the probe be painted or coated?\u003c\/p\u003e\n\u003cp\u003eA: No, any coating on the probe tip will create a false gap and attenuate the eddy-current signal response.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What happens if the probe tip touches the rotating shaft?\u003c\/p\u003e\n\u003cp\u003eA: Physical contact can damage the probe tip and produce erroneous voltage spikes, potentially triggering an alarm in the monitor system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the probe protected against moisture?\u003c\/p\u003e\n\u003cp\u003eA: The ClickLoc connector and probe case are designed to prevent moisture ingress, provided they are correctly installed and tightened.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46026738860205,"sku":"330173-00-03-10-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xian-58_1a35bd4d-e1fd-4781-a0ad-17b04492c823.jpg?v=1783665696","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330173-00-03-10-02-00-bently-nevada-3300-5mm-proximity-probes-3300-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}