{"product_id":"330130-040-02-cn-bently-nevada-3300-xl-series-extension-cable","title":"330130-040-02-CN Bently Nevada 3300 XL Series Extension Cable","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330130-040-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eserves as the primary\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330130\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable utilized to execute high-frequency RF signal transmission across 3300 XL Series platforms. Configured as a passive, low-attenuation coaxial bridge within an eddy-current proximity transducer loop, this hardware connects the proximity probe to a Proximitor Sensor to transfer physical machine displacement data back to the processing monitor rack without phase distortion.\u003c\/p\u003e\n\u003ch3\u003eOption Code Parameter Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe distinct alphanumeric suffixes designate the predefined physical length, shielding armor, and regional certification properties of the cable assembly:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330130\u003c\/strong\u003e: Base model designator for the 3300 XL 8mm proximity extension cable system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e040\u003c\/strong\u003e: Cable Length option. Standardizes an absolute nominal length of 4.0 meters (13.1 feet).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Armor option. Standard coaxial cable configuration outfitted with a stainless steel braided armor sleeve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Agency Approval option. Specifies local regulatory certifications and compliance for installation within specialized industrial regions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical and Physical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330130-040-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.31 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e26.0 cm x 26.0 cm x 4.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.0 W (Passive electrical element)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCharacteristic Impedance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 ohms nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInsulation Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFluorinated Ethylene Propylene (FEP)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Loop Tuning and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe capacitive and inductive electrical profiles of the 330130 cable series are matched to specialized eddy-current probe scaling matrices. Modifying the physical length of this line skews loop impedance parameters, which compromises the field gap voltage validation routines targeting a precise -10 VDC baseline at the monitor. The high-density external stainless steel braided armor layer provides integrated cross-talk suppression, shielding the micro-volt sensor loops from electromagnetic field interference caused by adjacent heavy machinery.\u003c\/p\u003e\n\u003ch3\u003eStandard Factory Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Bently Nevada 330130-040-02-CN Armored Extension Cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Removable silicone ClickLoc connector insulation sleeve.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Deployment and Routing Instructions\u003c\/h3\u003e\n\u003ch3\u003ePhysical Layout Limits\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnforce a strict minimum physical bend radius of 25.4 mm (1.0 inch) along all segments of the armored coaxial run.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the external stainless steel braided armor sleeve to structural supports at 300 mm intervals to isolate the line from machinery vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain physical separation between sensor routing tracks and high-voltage AC electric power lines using dedicated metal conduits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eClickLoc Connector Interface Engagement\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInspect internal mating surfaces of the ClickLoc connectors to confirm they are dry and free of particulate debris.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlign the male and female terminal joints and push together firmly until the internal mechanical detent locks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlide the silicone connector protector completely over the mated junction to block external environmental oil ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTransducer System Engineering FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this 4.0-meter extension cable be paired with a 1.0-meter proximity probe?\u003c\/p\u003e\n\u003cp\u003eYes. This setup creates a 5.0-meter total system loop length, which must be connected to a matching 5.0-meter 3300 XL Proximitor module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to the monitor reading if the internal FEP insulation layer is crushed?\u003c\/p\u003e\n\u003cp\u003eCrushing modifies the internal core-to-shield capacitance, shifting the eddy-current probe scaling constants and inducing measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhere should the electrical shield layer of this extension cable be grounded?\u003c\/p\u003e\n\u003cp\u003eThe shield must remain isolated from the machine frame and terminate to earth ground solely at the Proximitor Sensor terminal chassis block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat fault state is indicated during an open-circuit failure inside the coaxial core?\u003c\/p\u003e\n\u003cp\u003eThe companion 3500 series monitor rack reports a \"Not OK\" status fault and clamps the transducer output to its maximum negative rail limit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan field technicians cut and re-terminate this cable to eliminate physical slack?\u003c\/p\u003e\n\u003cp\u003eNo. Cutting shifts the absolute line impedance, which invalidates the pre-calibrated scale factor of 7.87 V\/mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does oil contamination inside the ClickLoc connection affect loop behavior?\u003c\/p\u003e\n\u003cp\u003eOil shifts the baseline gap voltage validation target away from the nominal -10 VDC point, causing false drift or vibration alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the FEP insulation jacket resilient against continuous exposure to ammonia or steam?\u003c\/p\u003e\n\u003cp\u003eYes. The fluoropolymer formulation provides robust chemical resistance against corrosive gases, steam, and synthetic lubricants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this passive cable component be hot-swapped while the machinery monitor is powered?\u003c\/p\u003e\n\u003cp\u003eYes. The passive sensor lead can be safely decoupled from the probe tail while the primary monitor chassis remains active.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518763425965,"sku":"330130-040-02-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330130-040-02-cn-extension-cable-etjf053zz2o.jpg?v=1766977064","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330130-040-02-cn-bently-nevada-3300-xl-series-extension-cable","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}