{"product_id":"330106-05-30-50-02-00-bently-nevada-extension-cable-3300-xl","title":"330106-05-30-50-02-00 Bently Nevada Extension Cable 3300 XL","description":"\u003cp\u003eConfigured for signal transmission between proximity probes and Proximitor sensors in TSI monitoring platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330106-05-30-50-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330106-05-30-50-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExtension Cable) provides direct physical electrical execution for eddy-current transducer systems.\u003c\/p\u003e\n\u003ch3\u003eModel Identifier Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330106: 3300 XL 8 mm Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Cable Length (5.0 meters)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e30: Connector Option (Standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e50: Agency Approval (Multiple Approvals)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector Protector Option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: No Standard Option\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330106-05-30-50-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.30 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 cm x 25 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (No active draw)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCable Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 Ohm Triaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Cross-Talk Suppression\u003c\/h3\u003e\n\u003cp\u003eThe 330106 extension cable is integral to maintaining the system-wide impedance necessary for accurate rotor dynamics monitoring. The triaxial construction incorporates high-frequency shielding to ensure effective cross-talk suppression between adjacent transducer channels. When installed, the cable preserves the 7.87 V per mm (200 mV\/mil) scale factor established by the probe and Proximitor pairing. Technicians must ensure that gap voltage validation is performed after installation; the target gap voltage at the probe tip should remain -10 VDC when the shaft is centered within the probe linear range to ensure measurement linearity.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330106-05-30-50-02-00 Extension Cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector Protection Kit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Compliance Documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCable Routing: Observe a minimum bend radius of 25 mm. Exceeding this limit can cause permanent damage to the coaxial core and shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Engagement: Tactile feedback is required when latching ClickLoc connectors. Ensure the locking mechanism is fully seated to prevent ingress of contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShield Continuity: The cable shield must remain continuous through the connector interface. Avoid grounding the cable shield at multiple points to prevent ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConduit Protection: Use flexible liquid-tight conduit for outdoor or harsh chemical environments to provide mechanical strain relief for the cable assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Frequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this extension cable be used with non-XL 3300 Proximitors?\u003c\/p\u003e\n\u003cp\u003eNo. The 3300 XL system is impedance-matched as a set. Mixing non-XL components will result in incorrect scale factors and measurement drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs it possible to trim the cable to a shorter length?\u003c\/p\u003e\n\u003cp\u003eNo. Trimming alters the calibrated impedance of the cable, which will invalidate the system output and cause significant errors in vibration readings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the connector be protected during pulls?\u003c\/p\u003e\n\u003cp\u003eUse the provided connector protector or a suitable pull-sock to prevent mechanical stress on the ClickLoc interface during cable routing through conduit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum operating temperature for the cable jacket?\u003c\/p\u003e\n\u003cp\u003eThe FEP jacket is rated for operation up to 177 deg C, provided the environment does not expose the cable to mechanical stress at these limits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAre there specific torque requirements for the connectors?\u003c\/p\u003e\n\u003cp\u003eNo. ClickLoc connectors rely on a push-and-twist latch mechanism rather than threaded torque, though hand-tightening ensures the seal is fully seated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is signal loss determined over 5 meters?\u003c\/p\u003e\n\u003cp\u003eThe system is calibrated for a specific total length. Loss is negligible within the design length, provided the cable impedance remains within specified tolerances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this cable be used in vacuum applications?\u003c\/p\u003e\n\u003cp\u003eYes. The materials used in the 330106 assembly are generally compatible with vacuum environments, provided they are clean and free of outgassing lubricants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat indicates an open circuit in the cable?\u003c\/p\u003e\n\u003cp\u003eAn open circuit will cause the Proximitor to output a voltage near the negative supply rail (-24 VDC), signifying a loss of probe-to-sensor continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518809497773,"sku":"330106-05-30-50-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330106-05-30-50-02-00-extension-cable-vxmisjqj55h.jpg?v=1766979429","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330106-05-30-50-02-00-bently-nevada-extension-cable-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}