{"product_id":"330104-00-10-05-02-05-bently-nevada-3300-xl-series-proximity-probes","title":"330104-00-10-05-02-05 Bently Nevada 3300 XL Series Proximity Probes","description":"\u003cp\u003eConfigured for non-contacting displacement monitoring in mechanical platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-10-05-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104-00-10-05-02-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probes) provides direct physical and electrical execution of RF-based position signal conditioning.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e330104\u003c\/strong\u003e: Base Model (3300 XL 8 mm Proximity Probe)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Unthreaded Length (00 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Overall Case Length (10 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Total System Length (0.5 meter)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector Type (Miniature coaxial ClickLoc connector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Agency Approval (Multiple international standards)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-10-05-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm x 15 cm x 5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-35 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive transducer \/ Oscillator-dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eScale Factor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.87 V\/mm (200 mV\/mil)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL transducer system utilizes eddy-current probe scaling to convert shaft motion into a linear voltage signal. During installation, gap voltage validation against -10 VDC targets at the oscillator interface is required to ensure the probe tip operates within the optimal linear measurement range. The system supports rotor dynamics analysis by maintaining signal linearity. Cross-talk suppression is maintained through frequency-coded oscillator channels, preventing signal interference between adjacent proximity sensors in high-density machine configurations.\u003c\/p\u003e\n\u003ch3\u003e## Ordering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330104-00-10-05-02-05 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective connector thread caps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation technical documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting: Thread the probe into the mounting bracket; use a feeler gauge to verify the air gap matches design specifications for a -10 VDC gap voltage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Route coaxial cabling through grounded metallic conduit to protect against electromagnetic interference; observe minimum cable bend radii.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Secure the probe body to the machine housing to establish a consistent electrical ground reference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Check: Verify all coaxial connections are clean, hand-tightened, and free of moisture or particulates to ensure electrical integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Validation: Perform a static gap voltage check using a high-impedance voltmeter at the oscillator output prior to machine startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this probe compatible with standard 11 mm probe oscillators?\u003c\/p\u003e\n\u003cp\u003eA: No, this 8 mm probe must be paired with a matched 8 mm oscillator to maintain correct scaling and frequency response.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the probe gap validated?\u003c\/p\u003e\n\u003cp\u003eA: The gap is validated by measuring the output voltage at the oscillator terminals; the system target is -10 VDC at the nominal gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the coaxial cable be field-spliced?\u003c\/p\u003e\n\u003cp\u003eA: No, field-splicing modifies the electrical resonance and impedance of the transducer system, which invalidates the factory-calibrated scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What effect does the target material have on the output?\u003c\/p\u003e\n\u003cp\u003eA: Probe sensitivity is calibrated for 4140 steel; other materials require a scaling factor adjustment to ensure measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the function of the connector protector cap?\u003c\/p\u003e\n\u003cp\u003eA: The cap prevents dust, oil, and environmental contaminants from entering the connector interface during installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the probe require an external power supply?\u003c\/p\u003e\n\u003cp\u003eA: No, the probe is a passive device; excitation power is supplied via the radio-frequency carrier generated by the oscillator.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What causes unstable or drifting signal readings?\u003c\/p\u003e\n\u003cp\u003eA: Instability is often caused by loose coaxial connections, electrical ground loops, or physical damage to the probe tip.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Should thread-locking compound be used during installation?\u003c\/p\u003e\n\u003cp\u003eA: No, thread-locking compounds may create an insulating barrier that disrupts the electrical ground path between the probe and machine casing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518822408365,"sku":"330104-00-10-05-02-05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-10-05-02-05-3300-xl-8-mm-proximity-probes-3b20kv2225q.jpg?v=1766979588","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330104-00-10-05-02-05-bently-nevada-3300-xl-series-proximity-probes","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}