{"product_id":"330104-00-08-05-02-05-bently-nevada-proximity-probe-3300-xl","title":"330104-00-08-05-02-05 Bently Nevada Proximity Probe 3300 XL","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-08-05-02-05\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe, operates as a dedicated hardware component for non-contacting displacement and vibration monitoring within rotating machinery platforms.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Matrix and Suffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 330104-00-08-05-02-05 part number specifies:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e00: Metric M10 x 1 thread without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e08: 80 mm case length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: 0.5 meter (1.6 feet) total system length.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Miniature coaxial ClickLoc connector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: CSA, ATEX, and IECEx hazardous area approvals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-08-05-02-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.14 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e11.0 x 1.8 x 1.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM10 x 1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConnector Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eClickLoc Miniature Coaxial\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eRotor Dynamics and Transducer Scaling\u003c\/h3\u003e\n\u003cp\u003eThe 3300 XL system utilizes eddy-current probe scaling to ensure linear displacement output. During system commissioning, gap voltage validation is performed to align the transducer tip with the -10 VDC target, providing the reference required for accurate radial vibration and axial position measurement. The probe design incorporates cross-talk suppression to maintain signal integrity in high-density installations, preventing mutual interference between multiple proximity channels on the same rotating assembly.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330104-00-08-05-02-05 Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Installation hardware set (mounting nuts).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical manual set.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eThread the probe into the mounting bracket until the required gap is achieved.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjust the probe depth to reach a nominal -10 VDC reading at the monitor rack.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSecure the transducer using the provided locknuts to prevent mechanical shift due to machine vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Connection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the ClickLoc connector is fully seated to prevent signal noise or intermittency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain shield continuity to the monitoring system ground to minimize common-mode noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the frequency response of this probe?\u003c\/p\u003e\n\u003cp\u003eThe probe supports a frequency range from 0 to 10 kHz (-3 dB), suitable for both static displacement and dynamic vibration analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in hazardous locations?\u003c\/p\u003e\n\u003cp\u003eYes, the 05 suffix indicates compliance with CSA, ATEX, and IECEx standards for operation in classified hazardous areas.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe field-repairable?\u003c\/p\u003e\n\u003cp\u003eNo, the transducer is a factory-calibrated assembly. Any attempt to repair the cable or probe tip will compromise measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the ClickLoc connector used?\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector provides a secure, vibration-resistant connection that prevents accidental disconnection during mechanical operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I replace the 0.5 meter cable with a longer one?\u003c\/p\u003e\n\u003cp\u003eNo, the system is calibrated as a matched set; changing the cable length alters the electrical resonance and invalidates the output linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the gap voltage range?\u003c\/p\u003e\n\u003cp\u003eThe linear operating range is typically set around a -10 VDC reference; deviations indicate the probe is outside the linear transduction range.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe compatible with 3300 XL extension cables?\u003c\/p\u003e\n\u003cp\u003eYes, this probe is compatible with standard 3300 XL extension cables and Proximitor sensors, provided the total system length is consistent.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify the probe thread type?\u003c\/p\u003e\n\u003cp\u003eThe 00 suffix denotes an M10 x 1 metric thread configuration for installation into standardized machinery mounting brackets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518761853101,"sku":"330104-00-08-05-02-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-08-05-02-05-3300xl-8-mm-proximity-probes-kmvwemhgl21.jpg?v=1766977044","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330104-00-08-05-02-05-bently-nevada-proximity-probe-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}