{"product_id":"330104-00-08-05-01-05-bently-nevada-proximity-probes-3300-xl","title":"330104-00-08-05-01-05 Bently Nevada Proximity Probes 3300 XL","description":"\u003cp\u003eConfigured for high-precision rotor vibration and position measurement, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-08-05-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104-00-08-05-01-05\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 mm Proximity Probes) provides direct physical execution of eddy-current displacement sensing within turbine monitoring (TSI) systems, specifically designed for internal armor protection.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe 330104-00-08-05-01-05 adheres to the Bently Nevada 3300 XL 8 mm system nomenclature:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330104: 8 mm probe with internal armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Unthreaded length (0 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e08: Overall case length (80 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Total length (0.5 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e01: Connector type (Miniature coaxial connector).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Agency approval (CSA\/NRTL\/C).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-08-05-01-05\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.18 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25.0 x 25.0 x 6.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Loop Powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Probe and TSI Characteristics\u003c\/h3\u003e\n\u003cp\u003eThis transducer system operates on the eddy-current principle, requiring precise probe scaling to maintain linear output over the measurement range. Proper gap voltage validation is a mandatory commissioning step; the target operational setpoint is -10 VDC to ensure the probe remains in the linear region of the transducer curve. The 3300 XL system incorporates internal cross-talk suppression, ensuring that adjacent probes in high-density rack configurations do not interfere with vibration data. The internal armor provides mechanical integrity in environments where cables are susceptible to debris or physical impact, making this probe assembly suitable for monitoring rotor dynamics, shaft centerline position, and radial vibration in demanding industrial machinery.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330104-00-08-05-01-05 Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective tip cover.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical compliance documentation (CSA\/NRTL\/C certified).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Extension cables and Proximitor sensors are sold separately and must be compatible with the 3300 XL 8 mm system impedance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Alignment: Ensure the probe is mounted perpendicularly to the target shaft; use a rigid bracket to prevent mechanical resonance and bias.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Setting: Establish the mechanical gap using a depth micrometer; verify the output voltage at the Proximitor terminal block (Target: -10 VDC).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Route the armored coaxial lead through dedicated conduit or cable trays; maintain separation from high-voltage lines to prevent induced noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Engagement: Ensure miniature coaxial connectors are clean and fully seated; apply a straight-line force until the connector clicks to confirm electrical continuity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThread Management: Apply torque to mounting jam nuts to secure the probe position, ensuring that vibration does not cause the gap to drift during machine operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the internal armor on this probe?\u003c\/p\u003e\n\u003cp\u003eThe internal armor protects the coaxial cable from physical damage, abrasions, or debris in industrial environments, ensuring signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require a matched extension cable?\u003c\/p\u003e\n\u003cp\u003eYes. The 3300 XL system is calibrated as a set (Probe + Extension Cable + Proximitor); replacing components requires verifying system-wide calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I use this probe in a hazardous area?\u003c\/p\u003e\n\u003cp\u003eThe \"05\" suffix indicates CSA\/NRTL\/C agency approval, making it suitable for specified hazardous locations; verify local certification requirements before installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is signal integrity maintained over the 0.5 meter lead length?\u003c\/p\u003e\n\u003cp\u003eThe cable uses high-quality shielding and impedance-controlled geometry to minimize signal attenuation and RFI interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the target gap voltage for this model?\u003c\/p\u003e\n\u003cp\u003eThe target gap voltage is -10 VDC, which positions the probe in the center of its linear range for optimal vibration measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe tip be repaired if damaged?\u003c\/p\u003e\n\u003cp\u003eNo. The probe tip is permanently sealed; any physical damage to the tip or body requires replacing the entire probe assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe affected by target material variations?\u003c\/p\u003e\n\u003cp\u003eYes. The transducer is calibrated for 4140 steel. If the target material differs, a scale factor adjustment or custom calibration is required to prevent measurement errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is a damaged cable identified by the TSI system?\u003c\/p\u003e\n\u003cp\u003eDamage typically results in a \"Gap Error\" signal on the monitor, caused by open or short circuits that drive the voltage outside the -10 VDC nominal target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518840823981,"sku":"330104-00-08-05-01-05","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330104-00-08-05-01-05-3300-xl-8-mm-proximity-probes-jutgp4eevux.jpg?v=1766980222","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330104-00-08-05-01-05-bently-nevada-proximity-probes-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}