{"product_id":"330104-00-02-50-02-00-bently-nevada-3300-xl-series-proximity-probe","title":"330104-00-02-50-02-00 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eConfigured for displacement and vibration monitoring in 3300 System platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330104-00-02-50-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330104\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal transduction for rotating machinery analysis. The transducer utilizes eddy-current induction to convert target surface proximity into linear voltage signals.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown and Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePart Number: 330104-00-02-50-02-00\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Type: 3300 XL 8 mm (with armor)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUnthreaded Length: 00 - 0.0 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCase Length: 02 - 0.2 in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTotal Length: 50 - 5.0 m (16.4 ft)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector: 02 - Miniature coaxial ClickLoc connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAgency Approval: 00 - Not required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330104-00-02-50-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 x 15 x 15 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Transducer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring and Transducer Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 330104 transducer relies on precise eddy-current probe scaling tuned for AISI 4140 steel targets. To ensure valid output, technicians must perform gap voltage validation, targeting -10 VDC at the linear range center. Accurate rotor dynamics measurement requires strict cross-talk suppression by maintaining a minimum 1.5 inch (38 mm) side-view clearance from the probe tip. Installations must ensure consistent shielding to minimize electrical noise during signal transmission from the transducer to the Proximitor sensor.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 330104 3300 XL 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Threaded mounting nut\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSecure the probe into the machine casing to achieve the required mechanical gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProximity Spacing:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaintain a 1.5 inch (38 mm) separation between probe tips for radial measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTarget Material:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the target surface is AISI 4140 steel for factory-calibrated linearity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eArmor Management:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the armored cable is properly terminated to prevent grounding issues or mechanical fatigue at the connector junction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this probe be used in high-temperature environments?\u003c\/p\u003e\n\u003cp\u003eThe probe is rated for operation up to 177 deg C, provided the temperature remains within the specifications for the internal potting and cabling materials.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the armor required for all installations?\u003c\/p\u003e\n\u003cp\u003eArmor is recommended for environments where mechanical impact or heavy debris poses a risk to the integrity of the coaxial cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe support direct replacement of older 3300 series probes?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL series is designed to be compatible with 3300 XL Proximitor sensors; check compatibility with existing Proximitor hardware before deployment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the 5.0 meter cable length?\u003c\/p\u003e\n\u003cp\u003eThis length is optimized for standard machine-to-junction-box distances, maintaining signal integrity without requiring external extension cables in many applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I calibrate the probe on-site?\u003c\/p\u003e\n\u003cp\u003eThe system is pre-calibrated. Field calibration is not recommended as it may deviate from the factory-verified sensitivity settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I identify a signal ground fault?\u003c\/p\u003e\n\u003cp\u003eA ground fault often manifests as excessive electrical noise or an erratic gap voltage reading that deviates from the -10 VDC target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the connector waterproof?\u003c\/p\u003e\n\u003cp\u003eThe ClickLoc connector is ingress-protected against dust and incidental moisture but is not rated for permanent submersion in liquids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the probe tip contacts the shaft?\u003c\/p\u003e\n\u003cp\u003eContact will lead to sensor damage or false data; ensure that the mechanical gap is always greater than the minimum physical clearance required.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":46025230024877,"sku":"330104-00-02-50-02-00","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/xianxian_09_42c58640-f5cb-4bf9-8957-f60ee78a53b6.jpg?v=1783583525","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330104-00-02-50-02-00-bently-nevada-3300-xl-series-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}