{"product_id":"330103-02-12-05-02-cn-bently-nevada-proximity-probe-3300-xl","title":"330103-02-12-05-02-CN Bently Nevada Proximity Probe 3300 XL","description":"\u003cp\u003eConfigured for shaft displacement measurements in 3300 XL monitoring systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330103-02-12-05-02-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330103\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution for gap-to-voltage signal conversion.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 330103 is an 8 mm proximity probe utilizing a 3\/8-24 thread configuration. The part number parameters include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Unthreaded length (0.2 inches).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e12\u003c\/strong\u003e: Overall case length (1.2 inches).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Total cable length (0.5 meters).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector option (Miniature coaxial ClickLoc).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCN\u003c\/strong\u003e: Approvals (Approvals variant).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330103-02-12-05-02-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.25 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 x 20 x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eSignal integrity in rotor dynamics monitoring is governed by precise eddy-current probe scaling. This transducer is calibrated for AISI 4140 steel targets; deviations in target metallurgy require specific sensitivity adjustments. Gap voltage validation targeting -10 VDC is mandatory to ensure linear output response. Proper installation requires maintaining specified counterbore clearances to facilitate cross-talk suppression, preventing capacitive interference between parallel signal loops within the machinery housing.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330103-02-12-05-02-CN Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 3\/8-24 stainless steel lock nut\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Silicone connector protective boot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Torque:\u003c\/p\u003e\n\u003cp\u003eApply a maximum torque of 13.5 N·m (120 in-lb) when securing the probe. Over-torqueing may result in mechanical deformation of the probe body.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCoaxial Cabling:\u003c\/p\u003e\n\u003cp\u003eRoute cables through rigid, grounded metal conduits to provide electromagnetic shielding and mitigate induced noise from high-voltage motor or drive cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Engagement:\u003c\/p\u003e\n\u003cp\u003eManually seat the ClickLoc connector interface until an audible click is detected. Avoid using metal tools to force connection, as this may compromise internal electrical contact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Protection:\u003c\/p\u003e\n\u003cp\u003eInstall protective boots over the connector interface to prevent moisture and oil ingress, which can induce resistive shunting or signal instability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs this probe compatible with standard 3300 XL Proximitor sensors?\u003c\/p\u003e\n\u003cp\u003eYes, the 330103 transducer is fully compatible with 3300 XL Proximitor units and requires no specialized system recalibration for standard applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the probe gap verified during operation?\u003c\/p\u003e\n\u003cp\u003eVerification is performed by measuring the DC output voltage from the Proximitor using a digital multimeter while the machine is at a known shaft position.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the probe measure static and dynamic signals simultaneously?\u003c\/p\u003e\n\u003cp\u003eYes, the eddy-current principle allows the transducer to capture both the DC shaft center-line position and the AC dynamic vibration signals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the cable length modification possible?\u003c\/p\u003e\n\u003cp\u003eNo. The cable is a fixed, factory-tuned component of the 3300 XL system. Splicing or modifying the cable alters its characteristic impedance and invalidates data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the -CN suffix indicate specific certification?\u003c\/p\u003e\n\u003cp\u003eThe -CN suffix denotes regional certification requirements. Verify that the site-specific safety and hazard area documentation aligns with these ratings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the probe tip contacts the target?\u003c\/p\u003e\n\u003cp\u003eMechanical contact causes wear on the tip, distorting the RF field and leading to erroneous vibration data or failure of the probe's internal components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is AISI 4140 steel the standard calibration target?\u003c\/p\u003e\n\u003cp\u003eThe sensitivity of the probe is dependent on the magnetic permeability and electrical conductivity of the target, which are standardized for this alloy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I replace the probe while the machine is running?\u003c\/p\u003e\n\u003cp\u003eReplacement is possible if the monitor channel is bypassed; otherwise, removing the probe will cause a signal loss condition triggering protective alarms.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518810022061,"sku":"330103-02-12-05-02-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330103-02-12-05-02-cn-3300-xl-8-mm-proximity-probes-qvnkhto4of3.jpg?v=1766979450","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330103-02-12-05-02-cn-bently-nevada-proximity-probe-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}