{"product_id":"330102-00-30-10-02-00-bently-nevada-3300-xl-series-proximity-probe","title":"330102-00-30-10-02-00 Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eConfigured for high-precision radial vibration and axial position measurement within the 3300 XL monitoring network, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330102-00-30-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330102\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal transduction. This hardware captures the instantaneous distance between the probe tip and a rotating conductive target, feeding the resulting signal to the Proximitor sensor for subsequent processing.\u003c\/p\u003e\n\u003ch3\u003eConfiguration Matrix \u0026amp; Suffix Analysis\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330102: 3300 XL 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Unthreaded Length (metric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e30: Overall Case Length (metric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Total Length (metric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Connector Type (Miniature coaxial ClickLoc connector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency Approval (Not required)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330102-00-30-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.28 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e22 cm x 18 cm x 12 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNegligible (Passive sensor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current \u0026amp; Signal Validation\u003c\/h3\u003e\n\u003cp\u003eThe probe functions via an inductive eddy-current principle, oscillating at a 1 MHz radio frequency. Accurate output is dependent on maintaining a -10 VDC gap voltage target during nominal machine operation to ensure the signal remains within the sensor's linear range. Cross-talk suppression between multiple probes must be managed by ensuring proper physical spacing, typically 40 mm or greater between probe tips, to prevent 1 MHz signal interference. Periodic rotor dynamics validation is required to ensure signal linearity remains consistent with the standard 7.87 V\/mm (200 mV\/mil) scale factor.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330102-00-30-10-02-00 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Protective connector cover\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical datasheet documentation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration conformity document\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Procedures\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTorque the mounting jam nut to the manufacturer-specified value using a torque wrench to ensure mechanical stability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the probe tip maintains a clearance of at least 10 mm from the side-walls of the installation hole to eliminate side-view errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute coaxial cabling through dedicated metallic conduit to provide shielding against electromagnetic field interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify electrical continuity at the monitor terminal block before initiating machine start-up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect connector ClickLoc mechanisms for mechanical debris prior to mating with the extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Inquiry Index\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this probe operate in high-pressure environments?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the probe tip and case are rated for pressure environments up to 60 bar when properly sealed with an appropriate O-ring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the probe grounded?\u003c\/p\u003e\n\u003cp\u003eA: The probe case is floating relative to the signal common to prevent ground loops; ensure the monitor common is tied to a single earth point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this probe with 5 m and 9 m systems interchangeably?\u003c\/p\u003e\n\u003cp\u003eA: No, the system is calibrated for a specific total length; altering the cable length changes the resonant frequency and amplitude.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the significance of the 1 MHz frequency?\u003c\/p\u003e\n\u003cp\u003eA: The 1 MHz oscillator is selected to optimize the eddy-current depth of penetration for standard 4140 steel targets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the PPS tip require special handling?\u003c\/p\u003e\n\u003cp\u003eA: Avoid physical impact to the PPS tip; cracks or scratches can alter the magnetic field permeability and result in output drift.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Why is the gap voltage critical?\u003c\/p\u003e\n\u003cp\u003eA: If the gap exceeds the linear range (typically 2 mm), the signal will clip, resulting in inaccurate vibration data and potential monitoring system errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are these probes shielded against moisture?\u003c\/p\u003e\n\u003cp\u003eA: The probe assembly is hermetically sealed at the cable connection; however, use connector protectors for exposed connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I use this with non-ferrous targets?\u003c\/p\u003e\n\u003cp\u003eA: Probe scaling is calibrated for 4140 steel; using other materials requires a calibration factor adjustment to maintain measurement accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518836564141,"sku":"330102-00-30-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330102-00-30-10-02-00-3300-xl-8-mm-proximity-probes-tpgycj3cz3q.jpg?v=1766980053","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330102-00-30-10-02-00-bently-nevada-3300-xl-series-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}