{"product_id":"330101-05-30-10-02-00-bently-nevada-3300-xl-proximity-probe","title":"330101-05-30-10-02-00 Bently Nevada 3300 XL Proximity Probe","description":"\u003cp\u003eConfigured for non-contact shaft vibration and position monitoring in 3300 XL systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-05-30-10-02-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical\/electrical execution of gap-to-voltage signal conversion.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 330101 series represents the standard 8 mm probe configuration with a 3\/8-24 thread. The part number configuration is:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e05\u003c\/strong\u003e: Unthreaded length (0.5 inches).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e30\u003c\/strong\u003e: Overall case length (3.0 inches).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e10\u003c\/strong\u003e: Total cable length (1.0 meter).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e02\u003c\/strong\u003e: Connector option (Miniature coaxial ClickLoc).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e00\u003c\/strong\u003e: Agency approval (None).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-05-30-10-02-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.35 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e25 x 25 x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLinear Range\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.0 mm (80 mils)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical Monitoring \u0026amp; TSI Technical Attributes\u003c\/h3\u003e\n\u003cp\u003eAccurate rotor dynamics monitoring depends on strict eddy-current probe scaling. This system is factory-calibrated for AISI 4140 steel; any deviation from this target material requires specific sensitivity correction. During installation, gap voltage validation at -10 VDC is mandatory to ensure linear signal response. To maintain measurement integrity, engineers must enforce adequate counterbore clearance to facilitate cross-talk suppression and prevent signal interference from adjacent machine components in high-density transducer arrays.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330101-05-30-10-02-00 Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 3\/8-24 stainless steel lock nut\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protective boot set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Torque:\u003c\/p\u003e\n\u003cp\u003eMounting nuts must be tightened to a maximum of 13.5 N·m (120 in-lb). Exceeding this limit will compromise the thread integrity of the probe housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCoaxial Routing:\u003c\/p\u003e\n\u003cp\u003eRun cables through grounded rigid metal conduits to provide electromagnetic shielding against external interference and ground loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Engagement:\u003c\/p\u003e\n\u003cp\u003eManually seat the ClickLoc connector until an audible click is heard; do not use pliers, as excessive pressure can damage the internal contacts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Constraints:\u003c\/p\u003e\n\u003cp\u003eVerify that the probe mounting location remains within the specified -51 deg C to +177 deg C operating envelope to prevent degradation of the internal insulation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs this probe compatible with standard 3300 XL Proximitor sensors?\u003c\/p\u003e\n\u003cp\u003eYes. The 330101 transducer is designed for seamless integration with 3300 XL Proximitor units without requiring custom system recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the probe linear range defined?\u003c\/p\u003e\n\u003cp\u003eThe probe maintains a linear range of 2.0 mm (80 mils), centered at a nominal gap of 1.27 mm (50 mils) from the shaft target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the -00 suffix impact installation?\u003c\/p\u003e\n\u003cp\u003eThe -00 suffix indicates the unit does not have hazardous area agency approvals. Always verify that site safety requirements permit the use of non-rated hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I shorten the 1.0 meter cable?\u003c\/p\u003e\n\u003cp\u003eNo. The cable is a fixed length and is part of the calibrated transducer system. Modification alters electrical impedance and invalidates system accuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I perform a static calibration check?\u003c\/p\u003e\n\u003cp\u003eStatic calibration is performed using a micrometer fixture to plot gap versus voltage, ensuring the output remains within the specified -1 to -17 VDC linear operating band.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the probe tip sensitive to target material?\u003c\/p\u003e\n\u003cp\u003eYes. Sensitivity is optimized for AISI 4140 steel. Using other conductive materials will alter the scale factor and requires field sensitivity adjustments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat should I do if the connector boot is damaged?\u003c\/p\u003e\n\u003cp\u003eReplace the boot immediately. The boot provides essential protection against moisture and oil ingress, which can cause erratic readings in industrial environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I replace this probe while the machine is online?\u003c\/p\u003e\n\u003cp\u003eYes, but the associated monitor channel must be bypassed to prevent spurious alarms or machine trips during the removal and installation process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518810087597,"sku":"330101-05-30-10-02-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-05-30-10-02-00-proximity-probes-vmewxwxei0m.jpg?v=1766979452","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330101-05-30-10-02-00-bently-nevada-3300-xl-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}