{"product_id":"330101-00-08-10-11-00-bently-nevada-8-mm-proximity-probe-3300-xl","title":"330101-00-08-10-11-00 Bently Nevada 8 mm Proximity Probe 3300 XL","description":"\u003cp\u003eConfigured for high-precision displacement and vibration measurement in rotating machinery, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-08-10-11-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101-00-08-10-11-00\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e8 mm Proximity Probe) provides direct physical execution of eddy-current sensing within turbine monitoring (TSI) networks.\u003c\/p\u003e\n\u003ch3\u003eModel Nomenclature Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 330101-00-08-10-11-00 is structured according to Bently Nevada's 3300 XL 8 mm transducer system standards:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330101: 8 mm probe without armor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Unthreaded length (0 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e08: Overall case length (80 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e10: Total length (1.0 meter).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e11: Connector type (Miniature coaxial connector with housing).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Agency approval (Not required).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-08-10-11-00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.20 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20.4 x 22.2 x 3.7 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Loop Powered)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Diameter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eThread Specification\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/8-24 UNF\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEddy-Current Sensing and Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThis transducer system operates by inducing eddy currents in the target surface, requiring meticulous probe scaling to maintain linear output over the intended range. During installation, gap voltage validation is mandatory; the target setpoint of -10 VDC centers the probe within its linear region to ensure accurate vibration data. The 3300 XL system incorporates robust cross-talk suppression, preventing interference between adjacent probes in multi-channel TSI architectures. These characteristics allow the probe to precisely monitor rotor dynamics, detect shaft centerline position, and identify radial vibration signatures in high-velocity turbomachinery.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 330101-00-08-10-11-00 Proximity Probe.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtective tip cover.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTechnical compliance and installation documentation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Extension cables and Proximitor sensors are sold separately and must be impedance-matched to the 3300 XL system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Interface: Secure the probe in a rigid housing to minimize measurement bias; ensure the probe tip is perpendicular to the shaft target.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap Setting: Utilize a feeler gauge to establish the initial mechanical gap; verify the output voltage at the Proximitor terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Use appropriate cable ties to secure the coaxial lead, ensuring it does not touch rotating components or vibrate against sharp edges.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Handling: Mating connectors must be clean; avoid excessive axial force when connecting to extension cables to prevent center-pin damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironmental Protection: Apply dielectric grease to connector threads if the installation environment is prone to humidity or liquid exposure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the target gap voltage for this model?\u003c\/p\u003e\n\u003cp\u003eThe nominal gap voltage is -10 VDC, which ensures the probe is operating within its linear sensing range for accurate vibration measurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this probe compatible with older 3300 series Proximitors?\u003c\/p\u003e\n\u003cp\u003eThe 3300 XL probes are designed for the 3300 XL system; using them with legacy 3300 Proximitors may result in signal inaccuracy and require recalibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I shorten the 1.0 meter lead length?\u003c\/p\u003e\n\u003cp\u003eNo. The system is calibrated for a specific total length (Probe + Extension Cable); altering the lead length will invalidate the calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the 08 case length influence placement?\u003c\/p\u003e\n\u003cp\u003eThe 80 mm case length defines the physical insertion capacity; ensure the mounting bracket allows for this length to achieve the desired gap.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the 330101 probe suitable for high-pressure environments?\u003c\/p\u003e\n\u003cp\u003eThe probe tip and body are pressure-rated, but verify the mounting seal (e.g., O-ring or NPT fitting) is adequate for your specific pressure vessel requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is a failure indicated by the monitoring system?\u003c\/p\u003e\n\u003cp\u003eProbe failure is typically indicated by a \"Gap Error\" on the monitor display, often signaling a short circuit, open circuit, or voltage drift to the supply rail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is the thread specification 3\/8-24 UNF?\u003c\/p\u003e\n\u003cp\u003eThis thread pitch is standard for 8 mm probes to allow for fine adjustments during the gap setting process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this probe require grounding?\u003c\/p\u003e\n\u003cp\u003eThe probe body is grounded through the housing mount; ensure the mounting bracket has a low-impedance connection to the machine ground.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518844493997,"sku":"330101-00-08-10-11-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-08-10-11-00-3300-xl-8-mm-probe-22jogkq4dnq.jpg?v=1766980251","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330101-00-08-10-11-00-bently-nevada-8-mm-proximity-probe-3300-xl","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}