{"product_id":"330101-00-08-05-12-cn-bently-nevada-3300-xl-series-proximity-probe","title":"330101-00-08-05-12-CN Bently Nevada 3300 XL Series Proximity Probe","description":"\u003cp\u003eConfigured for high-frequency relative displacement monitoring in 3300 XL machinery protection systems, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 330101-00-08-05-12-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e330101\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe) provides direct physical signal transduction. This hardware captures instantaneous gap distance variations between the probe tip and a conductive target, supplying a modulated radio frequency signal to the Proximitor sensor for data conditioning and analysis.\u003c\/p\u003e\n\u003ch3\u003eModel Configuration Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e330101: 3300 XL 8 mm Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Unthreaded Length (metric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e08: Overall Case Length (metric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Total Length (metric)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12: Connector Type (Miniature coaxial ClickLoc connector with connector protector)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCN: Approvals (Country Specific\/Standard)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e330101-00-08-05-12-CN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.26 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 cm x 15 cm x 10 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Powered by Proximitor)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProbe Tip Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePolyphenylene Sulfide (PPS)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCase Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAISI 303 Stainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical \u0026amp; Electrical Transduction Characteristics\u003c\/h3\u003e\n\u003cp\u003eOperation of the probe is based on the eddy-current principle, with the oscillator driving the probe tip at 1 MHz. Accurate measurement of rotor dynamics requires strict adherence to the specified 7.87 V\/mm (200 mV\/mil) scale factor. Field validation must confirm a nominal -10 VDC gap voltage at the monitor output to maintain signal linearity. Furthermore, proper cross-talk suppression between adjacent probe installations is required to prevent 1 MHz frequency interference, which may otherwise introduce harmonic noise into the vibration data stream.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 330101-00-08-05-12-CN Proximity Probe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Factory Calibration Certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Connector protector (installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMechanical Mounting: Torque the mounting jam nut to established specifications to prevent looseness caused by machine vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSide-View Clearance: Ensure a minimum of 10 mm clearance from the mounting hole wall to avoid peripheral metal interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling: Route coaxial cables through dedicated grounded metallic conduit, separating signal lines from high-voltage AC cabling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Integrity: Verify the ClickLoc coupling is fully seated; ensure the connector protector is secure to prevent moisture ingress.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Validation: Measure the output voltage at the Proximitor sensor terminal block to verify proper gap adjustment during site commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the 330101 probe compatible with older 3300 series monitors?\u003c\/p\u003e\n\u003cp\u003eA: No, 3300 XL probes are specifically designed for the 3300 XL Proximitor sensor frequency response and cannot be interchanged with legacy series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can the PPS probe tip be exposed to high-pressure fluids?\u003c\/p\u003e\n\u003cp\u003eA: The probe assembly is rated for pressure environments up to 60 bar, provided proper O-ring sealing is utilized at the thread interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum allowable cable run?\u003c\/p\u003e\n\u003cp\u003eA: The system is calibrated for a total system length (Probe + Extension Cable) of 5 or 9 meters; exceeding this induces signal attenuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How is the probe case grounded?\u003c\/p\u003e\n\u003cp\u003eA: The probe case is electrically isolated from the signal common; ensure the monitor system is grounded according to the specific site wiring diagram.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can I cut the probe cable to length?\u003c\/p\u003e\n\u003cp\u003eA: No, cutting the cable alters the system's characteristic impedance and resonant frequency, leading to inaccurate measurement output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How to identify a failed probe?\u003c\/p\u003e\n\u003cp\u003eA: A failed probe typically presents as an open circuit or a hard-scale (full negative or positive) voltage reading at the Proximitor output.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does target material affect measurement accuracy?\u003c\/p\u003e\n\u003cp\u003eA: Probes are calibrated for 4140 steel. Using different conductive materials requires a modification to the nominal scale factor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the purpose of the 1 MHz carrier?\u003c\/p\u003e\n\u003cp\u003eA: The 1 MHz frequency is optimized for eddy-current penetration depth in standard carbon steel to provide high-fidelity dynamic displacement data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518834958509,"sku":"330101-00-08-05-12-CN","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-330101-00-08-05-12-cn-3300-xl-8-mm-proximity-lpqmktbarkq.jpg?v=1766979993","url":"https:\/\/www.maxwellplc.com\/ru\/products\/330101-00-08-05-12-cn-bently-nevada-3300-xl-series-proximity-probe","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}