{"product_id":"31000-26-05-00-100-03-02-bently-nevada-proximity-probe-housing-assemblies-31000-series","title":"31000-26-05-00-100-03-02 Bently Nevada Proximity Probe Housing Assemblies 31000 Series","description":"\u003cp\u003eConfigured for mechanical transducer containment in Turbine Supervisory Instrumentation (TSI) platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eBently Nevada 31000-26-05-00-100-03-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e31000-26-05-00-100-03-02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProximity Probe Housing Assemblies) provides direct physical execution of sensor depth positioning and environmental isolation.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e31000: Proximity probe housing series.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e26: Probe diameter compatibility (standard 8 mm \/ 11 mm variant specification).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e05: Mounting thread specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e00: Extension piece configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e100: Overall housing length (100 mm).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e03: Conduit fitting type.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e02: Material and coating specification.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31000-26-05-00-100-03-02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBently Nevada\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.85 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35.0 x 10.0 x 10.0 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-51 deg C to +177 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePassive (Mechanical)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHousing Material\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStainless Steel\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3\/4-14 NPT\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eMechanical TSI Integration\u003c\/h3\u003e\n\u003cp\u003eThe housing assembly facilitates precise eddy-current probe scaling by providing a rigid mechanical reference point. Correct installation ensures the transducer maintains the required gap distance from the rotor surface, allowing the Proximitor to output a linear signal within the nominal -10 VDC range. Mechanical stability is a requirement for accurate rotor dynamics interpretation; the assembly is constructed to mitigate resonance-induced noise and minimize cross-talk interference between adjacent proximity channels in high-density mounting arrays.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOne (1) 31000-26-05-00-100-03-02 Proximity Probe Housing Assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard lock nut and jam nut hardware.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eO-ring seal kit for pressure-tight installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: Verify machine port thread pitch compatibility prior to final torque application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Protocols\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePort Preparation: Clean the machine port of all residual thread sealant and metal particulates to ensure a pressure-tight seal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlignment: Ensure the housing remains perpendicular to the shaft centerline; verify that the probe tip can reach the target area without mechanical binding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDepth Setting: Establish the mechanical gap using a depth micrometer; tighten the lock nuts only after the required gap voltage is confirmed at the monitor input.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Secure the stainless steel housing to the machine chassis to maintain a consistent ground path for electromagnetic shielding.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConduit Management: Secure the coaxial cable within the conduit fitting; avoid sharp bend radii that can degrade the internal cable shield.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCan this housing be used for radial vibration monitoring?\u003c\/p\u003e\n\u003cp\u003eYes, it is designed for mounting proximity probes used in radial vibration, shaft axial position, and speed monitoring applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the impact of housing resonance on signal data?\u003c\/p\u003e\n\u003cp\u003eMechanical resonance in the housing assembly can introduce false vibration data or signal \"noise,\" necessitating a rigid, properly locked installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the housing material chemically inert?\u003c\/p\u003e\n\u003cp\u003eThe stainless steel housing resists common turbine lubricants and process contaminants, ensuring long-term structural integrity in harsh environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the conduit fitting utilized?\u003c\/p\u003e\n\u003cp\u003eThe integrated fitting secures protective conduit, shielding the transducer cable from environmental impact and physical abrasion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this assembly include the proximity probe?\u003c\/p\u003e\n\u003cp\u003eNo, the housing assembly is a mechanical component and does not include the transducer or extension cable.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the housing be used in high-pressure oil cavities?\u003c\/p\u003e\n\u003cp\u003eYes, when installed with appropriate thread sealant, the housing maintains the seal integrity of the machine casing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do I confirm the 100 mm length requirement?\u003c\/p\u003e\n\u003cp\u003eConfirm the machine port depth and the required stick-out distance; the 100 mm length is measured from the mounting thread to the conduit interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the housing grounding requirement critical?\u003c\/p\u003e\n\u003cp\u003eYes, maintaining a low-impedance ground path is a requirement to minimize RFI\/EMI interference on the sensitive eddy-current signal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518839709869,"sku":"31000-26-05-00-100-03-02","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-31000-26-05-00-100-03-02-proximity-probe-housingassemblies-qttehw3hd32.jpg?v=1766980176","url":"https:\/\/www.maxwellplc.com\/ru\/products\/31000-26-05-00-100-03-02-bently-nevada-proximity-probe-housing-assemblies-31000-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}