{"product_id":"2711p-t15c4d9-allen-bradley-hmi-terminal-panelview-plus-6","title":"2711P-T15C4D9 Allen-Bradley HMI Terminal PanelView Plus 6","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711P-T15C4D9\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2711P-T15\u003c\/strong\u003e HMI Terminal, operates as a dedicated hardware component for graphical process visualization and operator input control within EtherNet\/IP deterministic networks.\u003c\/p\u003e\n\u003ch3\u003eNomenclature Configuration\u003c\/h3\u003e\n\u003cp\u003eThe catalog number \u003cstrong\u003e2711P-T15C4D9\u003c\/strong\u003e delineates specific hardware build attributes for the PanelView Plus 6 1500 series. The \"T\" designates an analog resistive touchscreen operator interface, while \"15\" specifies the 15-inch color display size. Code \"C4\" indicates a standard display module paired with an integrated Ethernet port, RS-232 interface, and dual USB ports. The suffix \"D\" denotes 18 to 32 VDC input power requirements, and \"9\" identifies the Windows CE 6.0 operating system with extended features.\u003c\/p\u003e\n\u003ch3\u003eTechnical Performance Parameters\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-T15C4D9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.68 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e330 x 416 x 65 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e70 W max (24 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e15-inch Color Active Matrix TFT LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNative Resolution\u003c\/td\u003e\n\u003ctd\u003e1024 x 768 XGA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouchscreen Interface\u003c\/td\u003e\n\u003ctd\u003eAnalog Resistive Touch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45 EtherNet\/IP, 1 x RS-232, 2 x USB 2.0 Type A, 1 x USB 2.0 Type B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEthernet Communications \u0026amp; Firmware Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711P-T15C4D9\u003c\/strong\u003e executes real-time data exchange over EtherNet\/IP deterministic networks, enabling low-latency tag updating from Logix control platforms. The internal logic module features strict firmware flash compatibility across major revision levels, ensuring synchronous operational handshakes between runtime visual displays and backplane controller tags.\u003c\/p\u003e\n\u003ch3\u003eSupplied Hardware Kit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x 2711P-T15C4D9 PanelView Plus 6 Terminal Assembly\u003c\/li\u003e\n\u003cli\u003e1 x 2-Pin DC Power Terminal Block\u003c\/li\u003e\n\u003cli\u003e10 x Panel Mounting Clamps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePanel Integration \u0026amp; Wiring Instructions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCutout Preparation\n\u003cul\u003e\n\u003cli\u003eCut enclosure opening precisely to 305 x 387 mm. Ensure mounting surface edges are smooth, flat, and free of metal burrs to preserve sealing integrity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eClamp Torque Application\n\u003cul\u003e\n\u003cli\u003eInsert terminal into panel cutout. Install mounting clamps around bezel slots and torque screws evenly in an alternating cross pattern to 1.1 to 1.4 Nm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDC Power Connections\n\u003cul\u003e\n\u003cli\u003eStrip copper supply conductors (14 to 18 AWG rated at 75 deg C) to 7 mm. Insert wires into the DC terminal block and tighten screw terminals to 0.6 Nm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eGrounding Wire Installation\n\u003cul\u003e\n\u003cli\u003eFasten a minimum 14 AWG ground conductor from the chassis earth ground lug to the central enclosure ground bus to minimize noise interference.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTechnical Operations FAQ\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the hot-swap policy for the rear logic module assembly?\u003c\/p\u003e\n\u003cp\u003eThe logic module must not be removed or swapped while primary supply voltage is applied. Disconnect all input power prior to servicing the unit.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow much maximum surge current does the DC power circuit draw during startup?\u003c\/p\u003e\n\u003cp\u003eThe internal DC-to-DC power converter exhibits an inrush current peak reaching up to 15 A for less than 2 ms upon initial power application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to network comms if firmware flash execution fails mid-update?\u003c\/p\u003e\n\u003cp\u003eInterrupted firmware updates cause boot initialization failure. Recovery requires reloading firmware image binaries via an external SD card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the front panel glass resistant to high-pressure chemical washdowns?\u003c\/p\u003e\n\u003cp\u003eThe front bezel meets NEMA Type 12, 13, 4X (indoor use only) and IP66 ratings when properly torqued into an equivalent NEMA\/IP enclosure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat cable length limitation applies to the embedded RS-232 serial interface?\u003c\/p\u003e\n\u003cp\u003eThe RS-232 serial link must not exceed 15 m (50 ft) of shielded cable length when communicating with serial controllers to avoid signal degradation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the screen calibration executed if the touchscreen stops responding?\u003c\/p\u003e\n\u003cp\u003eAttach an external USB mouse to the front port, access maintenance mode via boot menu settings, and run the 4-point touch alignment routine.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of external memory media is supported for application data logging?\u003c\/p\u003e\n\u003cp\u003eThe unit supports standard Secure Digital (SD) memory cards and USB flash drives formatted with FAT32 filesystems for logging data files.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the internal backlight assembly be replaced in the field?\u003c\/p\u003e\n\u003cp\u003eYes, the backlight component inside the display module is field-replaceable using designated replacement lamp kits without replacing the entire display.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":47230584324269,"sku":"2711P-T15C4D9","price":1500.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley_2711p-t15c4d9_1.jpg?v=1786894523","url":"https:\/\/www.maxwellplc.com\/ru\/products\/2711p-t15c4d9-allen-bradley-hmi-terminal-panelview-plus-6","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}