{"product_id":"2711p-t12w22d9p-b-ser-b-allen-bradley-panelview-plus-6-hmi-terminal","title":"2711P-T12W22D9P-B SER B Allen-Bradley PanelView Plus 6 HMI Terminal","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711P-T12W22D9P-B SER B\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePanelView Plus 6\u003c\/strong\u003e HMI Terminal, operates as a dedicated hardware component for real-time visualization and touch operator input within EtherNet\/IP DLR networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Nomenclature \u0026amp; Catalog Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2711P\u003c\/strong\u003e: Bulletin identifier for PanelView Plus operator interface terminal hardware.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eT\u003c\/strong\u003e: Touchscreen operator interaction mechanism using analog resistive sensing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e12W\u003c\/strong\u003e: 12.1-inch widescreen color TFT liquid crystal display element.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e: High-performance architecture platform with dual Ethernet connectivity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e: Integrated dual 10\/100 Mbps RJ45 ports supporting Device Level Ring (DLR) topology.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD\u003c\/strong\u003e: Direct current operational voltage requirement (24 VDC nominal).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e9\u003c\/strong\u003e: Standard manufacturer enclosure styling without custom OEM logos.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eP\u003c\/strong\u003e: Performance series platform hardware execution unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB\u003c\/strong\u003e: Hardware Series B manufacturing revision code.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical and Environmental Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-T12W22D9P-B SER B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e340 x 385 x 180 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 W max (24 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e12.1-inch Widescreen TFT, 18-bit Color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1280 x 800 WXGA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Memory\u003c\/td\u003e\n\u003ctd\u003e1 GB RAM, 512 MB User Storage Flash\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating System\u003c\/td\u003e\n\u003ctd\u003eWindows 10 IoT Core\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterfaces\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45 EtherNet\/IP, 2 x USB, 1 x SD Slot, 1 x Audio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Routing \u0026amp; Firmware Flash Execution\u003c\/h3\u003e\n\u003cp\u003eThe terminal processes industrial data packets across EtherNet\/IP deterministic networks, maintaining active tag synchronization with ControlLogix and CompactLogix PLCs. Device configuration relies on strict firmware flash compatibility between the embedded Windows 10 IoT Core system layer and controller task execution cycles. Internal bus bandwidth prevents network latency spikes during high-density graphical polling and alarm logging events.\u003c\/p\u003e\n\u003ch3\u003eFactory Supply List\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Allen-Bradley 2711P-T12W22D9P-B SER B Terminal\u003c\/li\u003e\n\u003cli\u003e1 x 2-Pin Removable DC Power Connector Plug\u003c\/li\u003e\n\u003cli\u003e8 x Panel Mounting Clamps\u003c\/li\u003e\n\u003cli\u003e1 x Installation Sheet and Panel Cutout Guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMechanical Mounting \u0026amp; Enclosure Wiring Protocols\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePanel Cutout Dimensioning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCut the enclosure opening precisely to the dimensions specified on the cutout template. Remove all metal shavings and deburr the perimeter to guarantee a flat gasket seal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Hardware Fixation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eInsert the unit into the cutout. Install the eight mounting clamps around the perimeter slots and tighten evenly in a crisscross pattern to 0.9-1.1 Nm to maintain front bezel seal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDC Voltage Line Wiring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRoute 24 VDC power through 14-18 AWG copper conductors connected to the removable two-terminal plug. Verify polarity before applying power to prevent internal fuse tripping.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEarthing and Shielding Alignment\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConnect a dedicated low-impedance ground strap from the back frame chassis ground stud directly to the main cabinet bus bar to reject high-frequency electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Operational Diagnostics FAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the dual-port Ethernet interface handle network link failures?\u003c\/p\u003e\n\u003cp\u003eThe dual RJ45 ports run Device Level Ring (DLR) protocols, enabling sub-millisecond fault recovery without losing data packets during loop breaks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage limits are supported by this DC-powered terminal?\u003c\/p\u003e\n\u003cp\u003eThe unit operates on 24 VDC nominal power, maintaining stable operation within an acceptable input range of 18 to 30 VDC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are local system fault codes monitored on the rear panel?\u003c\/p\u003e\n\u003cp\u003eIntegrated diagnostic status LEDs on the back chassis report boot progress, OS execution errors, and active network communication faults.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan external flash drives be used for datalogging and runtime updates?\u003c\/p\u003e\n\u003cp\u003eYes, the onboard USB 2.0 host ports and SD card slot support external FAT32 media for direct application loading and trending export.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat ambient temperature threshold triggers thermal degradation?\u003c\/p\u003e\n\u003cp\u003eOperating the unit above 55 deg C ambient air temp inside the enclosure can cause thermal throttling of the processor and premature display backlight dimming.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping the primary DC terminal block allowed while powered?\u003c\/p\u003e\n\u003cp\u003eNo, removing the live 24 VDC terminal plug causes localized electrical arcing and risks damaging internal power regulator components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the touchscreen assembly support multi-touch input modes?\u003c\/p\u003e\n\u003cp\u003eThe touch interface accepts tap, drag, and long-press single-point gestures engineered for industrial operator control actions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhy is firmware flash compatibility required for controller connections?\u003c\/p\u003e\n\u003cp\u003eMatching firmware revisions between the terminal runtime and controller guarantees native symbol decoding without unaligned tag errors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45519109128365,"sku":"2711P-T12W22D9P-B","price":699.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/allen-bradley-2711p-t12w22d9p-b-ser-b-touch-screen-film-qigblsnx3xo.jpg?v=1766987290","url":"https:\/\/www.maxwellplc.com\/ru\/products\/2711p-t12w22d9p-b-ser-b-allen-bradley-panelview-plus-6-hmi-terminal","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}