{"product_id":"2300-20-00-bently-nevada-vibration-monitor-2300-series","title":"2300\/20-00 Bently Nevada Vibration Monitor 2300 Series","description":"\u003cp\u003eThe \u003cstrong\u003eBently Nevada 2300\/20-00\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2300\/20\u003c\/strong\u003e Vibration Monitor Protection Unit, operates as a dedicated hardware component for continuous machinery protection and dynamic signal processing within 2300 Series monitoring architectures.\u003c\/p\u003e\n\u003ch3\u003eModel Number Structure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e2300\/20\u003c\/strong\u003e: Base dual-channel vibration and speed monitor unit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-00\u003c\/strong\u003e: Standard order option code denoting default hardware package, mounting hardware, and standard firmware setup without hazardous area regional certifications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSystem Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2300\/20-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e30.1 cm x 19.0 cm x 5.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 deg C to +65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e18 to 36 VDC, 7.5 Watts maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Channels\u003c\/td\u003e\n\u003ctd\u003e2 single-ended channels (Accelerometer, Velomitor, or Proximitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpeed Channels\u003c\/td\u003e\n\u003ctd\u003e1 dedicated tachometer input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Processing\u003c\/td\u003e\n\u003ctd\u003eProgrammable bandpass filters 0.2 Hz to 20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull-Scale Acceleration\u003c\/td\u003e\n\u003ctd\u003e2 to 80 g peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003eProgrammable dry-contact relays, 4-20 mA DC analog\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Rotor Dynamics\u003c\/h3\u003e\n\u003cp\u003eThe 2300\/20-00 processes raw dynamic signals from proximity sensors requiring gap voltage validation targeted at -10 VDC to verify correct probe position relative to the shaft surface. Signal processing circuits maintain high signal-to-noise ratios, providing cross-talk suppression between channels during high-frequency shaft oscillation. This hardware architecture supports 1X vibration tracking and phase angle detection using the dedicated speed channel, enabling detailed rotor dynamics analysis across operating speed ranges.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x Bently Nevada 2300\/20-00 monitor hardware assembly\u003c\/li\u003e\n\u003cli\u003e1 x Terminal block connector set\u003c\/li\u003e\n\u003cli\u003e1 x Panel mount hardware package\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCabinet Installation Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the unit vertically on standard DIN-rails or directly on a panel surface to allow convection cooling.\u003c\/li\u003e\n\u003cli\u003eMaintain minimum 50 mm clearance above and below the chassis for ambient airflow.\u003c\/li\u003e\n\u003cli\u003eRoute dynamic signal cables inside grounded metallic conduits separate from high-voltage AC mains wiring.\u003c\/li\u003e\n\u003cli\u003eConnect shield wires to the dedicated chassis ground point at one end only to stop ground loops.\u003c\/li\u003e\n\u003cli\u003eTighten field terminal block screws to a maximum torque rating of 0.5 Nm.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Questions \u0026amp; Answers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eHow is gap voltage configured for proximity probes connected to this unit?\u003c\/p\u003e\n\u003cp\u003eThe transducer channel accepts standard -24 VDC powered proximity probes calibrated for -10 VDC nominal gap voltage center targets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat output types are available for external interlocks?\u003c\/p\u003e\n\u003cp\u003eThe unit incorporates integrated dry-contact programmable relay outputs that drive automated equipment shutdown loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes the module support isolated analog outputs?\u003c\/p\u003e\n\u003cp\u003eConfigurable 4-20 mA DC analog outputs provide real-time trend signal transmission directly to DCS or PLC analog inputs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the dynamic input channels accept piezo-velocity transducers?\u003c\/p\u003e\n\u003cp\u003eYes, the input channels configure via software to interface with Velomitor piezo-velocity sensors or standard accelerometers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat supply voltage range must be provided to the terminal connectors?\u003c\/p\u003e\n\u003cp\u003eThe unit requires a filtered DC input supply operating within the range of 18 to 36 VDC at 7.5 Watts maximum power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow are frequency passbands defined within the DSP circuit?\u003c\/p\u003e\n\u003cp\u003eDigital filters set lower and upper cut-off frequencies anywhere within the total hardware bandwidth of 0.2 Hz to 20 kHz.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the purpose of the third input channel on the terminal block?\u003c\/p\u003e\n\u003cp\u003eThe dedicated speed input reads tachometer pulse signals to measure rotational velocity and establish phase reference vectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is signal cable shielding landed at the monitor terminal block?\u003c\/p\u003e\n\u003cp\u003eShield wires must land on designated SHIELD terminals on the unit and remain floating at the sensor housing end.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45518865989805,"sku":"2300\/20-00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/bently-nevada-2300-20-00-vibrationmonitors-nxj1y4mhuwm.jpg?v=1766980523","url":"https:\/\/www.maxwellplc.com\/ru\/products\/2300-20-00-bently-nevada-vibration-monitor-2300-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}