{"product_id":"20g11nc015ja0nnnnn-allen-bradley-powerflex-755-ac-drive","title":"20G11NC015JA0NNNNN Allen-Bradley PowerFlex 755 AC Drive","description":"\u003cp\u003eConfigured for variable speed motor control in industrial automation platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20G11NC015JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e20G11NC015JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive) provides direct electrical execution of pulse-width modulation (PWM) output to regulate induction motor frequency and torque.\u003c\/p\u003e\n\u003ch3\u003eCatalog Designation and Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: PowerFlex 755\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Rating: IP20\/IP00 (Open Type)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Configuration: AC Input with Precharge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Rating: 400 VAC \/ 540 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Rating: 15.4 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Rating: 7.5 kW \/ 10 HP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFeature Set: Internal Transistor, Filtering, Jumper Installed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical and Electrical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20G11NC015JA0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 x 40.5 x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 VAC \/ 540 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15.4 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.5 kW \/ 10 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20\/IP00\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDrive Communication and Control Logic\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 755 architecture supports deterministic network integration via EtherNet\/IP, facilitating seamless communication between the drive and plant-wide control systems. The firmware flash compatibility ensures that control algorithms remain consistent with updated safety and operational protocols. Deterministic performance is maintained through high-speed internal bus communication, allowing for precise synchronization in multi-axis motion applications where timing jitter must be minimized to maintain process stability.\u003c\/p\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 unit 20G11NC015JA0NNNNN PowerFlex 755 AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 set internal precharge circuit componentry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 set terminal block jumpers (factory installed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 documentation package (installation and quick start guide)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Integration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Environment: Install in a clean, dry, and ventilated cabinet to maintain optimal ambient temperature. Ensure sufficient clearance (minimum 100 mm) above and below the unit for convection cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Use a low-impedance ground connection. Ensure the PE (Protective Earth) terminal is securely connected to the cabinet common ground to mitigate electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWiring: Utilize shielded twisted-pair cables for signal control and segregated conduits for power input\/motor output to prevent high-frequency noise injection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrecharge Circuit: Do not bypass the internal precharge circuit; ensure the DC bus voltage is stable before initiating high-speed operation commands.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this drive support hot-swapping of control modules?\u003c\/p\u003e\n\u003cp\u003eNo, the control module should not be removed or inserted while the drive is powered, as this can cause damage to the communication backplane and internal logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum operating temperature for this unit?\u003c\/p\u003e\n\u003cp\u003eThe drive is designed for standard industrial environments up to 50 deg C; derating is required for altitudes exceeding 1000 meters or higher ambient temperatures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external line reactor required for this model?\u003c\/p\u003e\n\u003cp\u003eWhile the unit includes internal filtering, an external line reactor is recommended in installations with high-impedance power sources to reduce harmonic distortion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this drive be used in a common DC bus configuration?\u003c\/p\u003e\n\u003cp\u003eYes, as indicated by the 540 VDC rating, the unit can be integrated into a shared DC bus system provided the precharge sequence is coordinated with other drives.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the drive programmed?\u003c\/p\u003e\n\u003cp\u003eProgramming is performed via the EtherNet\/IP port using Studio 5000 Logix Designer software or the HIM (Human Interface Module) keypad interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the function of the internal transistor?\u003c\/p\u003e\n\u003cp\u003eThe internal transistor facilitates dynamic braking, allowing the drive to dissipate energy returned from the motor during deceleration phases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the IP20 rating suitable for washdown areas?\u003c\/p\u003e\n\u003cp\u003eNo, the IP20\/IP00 rating indicates an open-type enclosure that must be housed within an additional NEMA-rated cabinet to protect against moisture and particulates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the firmware be updated in the field?\u003c\/p\u003e\n\u003cp\u003eYes, firmware updates are supported via the ControlFLASH utility provided by the manufacturer, requiring a stable Ethernet connection to the drive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066469994669,"sku":"20G11NC015JA0NNNNN","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20G11Nc8-1_9f28a24f-ecf9-4d1c-a27f-2247cce40a40.jpg?v=1782295732","url":"https:\/\/www.maxwellplc.com\/ru\/products\/20g11nc015ja0nnnnn-allen-bradley-powerflex-755-ac-drive","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}