{"product_id":"20f1ane242jn0nnnnn-allen-bradley-powerflex-753-ac-drive","title":"20F1ANE242JN0NNNNN Allen-Bradley PowerFlex 753 AC Drive","description":"\u003cp\u003eConfigured for high-power induction motor control in industrial automation networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F1ANE242JN0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e20F1ANE242JN0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive) provides direct electrical execution of variable frequency power modulation to manage load acceleration and torque regulation.\u003c\/p\u003e\n\u003ch3\u003eModel Cataloging and Configuration\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: PowerFlex 753\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnclosure Type: IP20\/IP00, NEMA\/UL Type Open\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Architecture: AC Input with Precharge\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVoltage Rating: 600 VAC \/ 810 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Output: 242 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Rating: 185 kW \/ 250 HP\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperational Features: Filtering, Jumper Installed, No Internal Transistor, No HIM\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical and Physical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F1ANE242JN0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 x 40.5 x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600 VAC \/ 810 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eRated Output Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e242 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e185 kW \/ 250 HP\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard Industrial Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLoad Dependent\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control and Network Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 753 platform utilizes deterministic networks to execute motor control commands across complex automation architectures. Integration is supported through standardized EtherNet\/IP protocols, ensuring high-speed data exchange between the drive and the programmable logic controller (PLC). Firmware flash compatibility allows for lifecycle management, enabling the drive to adhere to changing network security standards and communication logic without requiring hardware replacement. The drive architecture supports I\/O density scaling through optional expansion slots, facilitating connection to local sensors and feedback devices.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 unit 20F1ANE242JN0NNNNN PowerFlex 753 AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 set factory-installed precharge jumpers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 set primary terminal block connectors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 technical documentation packet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Field Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCabinet Ventilation: Ensure the drive is installed within an enclosure that supports active airflow. Maintain minimum clearances of 150 mm above and below the unit to prevent thermal throttling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Protocols: Connect the chassis PE (Protective Earth) terminal directly to the central ground bus using a low-impedance conductor to minimize common-mode noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Use double-shielded, symmetrically constructed motor cables. Ground the shield at both the drive and the motor end to suppress radiated electromagnetic interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrecharge Integrity: Do not bypass the internal precharge circuit. Ensure that input power levels are verified before engaging the contactor to prevent inrush current damage to the capacitor bank.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external braking unit required for this drive?\u003c\/p\u003e\n\u003cp\u003eYes, as this model lacks an internal transistor, an external dynamic braking kit must be connected to the DC bus if active deceleration of high-inertia loads is necessary.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this drive be commissioned without a HIM module?\u003c\/p\u003e\n\u003cp\u003eYes, the drive can be configured via a networked PC using Studio 5000 Logix Designer or Connected Components Workbench software through the integrated communication ports.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the maximum cable length between the drive and the motor?\u003c\/p\u003e\n\u003cp\u003eMaximum cable length is dependent on the carrier frequency and cable capacitance; refer to the drive manual for specific de-rating tables to prevent excessive voltage reflections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this model support hot-swapping control I\/O?\u003c\/p\u003e\n\u003cp\u003eThe PowerFlex 753 control I\/O cards support hot-swapping; however, the main power structure must be de-energized and verified via a multimeter before maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow should the filtering jumper be configured?\u003c\/p\u003e\n\u003cp\u003eThe jumper should remain installed for standard grounded power systems. If utilizing an ungrounded or high-resistance grounded system, consult the installation guide for jumper removal.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the function of the 810 VDC rating?\u003c\/p\u003e\n\u003cp\u003eThis rating defines the maximum DC bus voltage input, intended for common DC bus applications where the drive is powered from an external DC power supply or shared bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the IP20 enclosure suitable for dusty environments?\u003c\/p\u003e\n\u003cp\u003eNo, the IP20\/IP00 open-type enclosure provides protection against large objects but requires a secondary NEMA-rated enclosure to prevent ingress of conductive dust or moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan I upgrade the firmware via the Ethernet port?\u003c\/p\u003e\n\u003cp\u003eYes, firmware updates are managed through the ControlFLASH utility, which requires a stable Ethernet link to the drive's communication card.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066469798061,"sku":"20F1ANE242JN0NNNNN","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-2.jpg?v=1782440965","url":"https:\/\/www.maxwellplc.com\/ru\/products\/20f1ane242jn0nnnnn-allen-bradley-powerflex-753-ac-drive","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}