{"product_id":"20f1and125ja0nnnnn-allen-bradley-powerflex-753-ac-drive","title":"20F1AND125JA0NNNNN Allen-Bradley PowerFlex 753 AC Drive","description":"\u003cp\u003eConfigured for frequency-controlled motor induction management in 480 VAC 3-phase electrical networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F1AND125JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003ePowerFlex 753\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive) provides direct physical electrical execution for variable speed applications.\u003c\/p\u003e\n\u003ch3\u003eModel Suffix Breakdown\u003c\/h3\u003e\n\u003cp\u003eThe 20F1AND125JA0NNNNN identifies a Frame 6 power chassis rated for 125 Amps output current. The designation specifies an AC input stage with integrated precharge circuitry, the absence of a dynamic braking transistor, and a factory-filtered EMC configuration with the common-mode (CM) jumper installed to address line-side conducted emissions.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F1AND125JA0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 cm x 40.5 cm x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eRefer to technical manual derating specifications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e100 HP (ND) \/ 75 HP (HD)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e125 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Type (IP20\/IP00)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control Deterministic Network Attributes\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 753 architecture supports high-speed data exchange via EtherNet\/IP or Profinet deterministic networks, ensuring synchronized motor control across multi-axis configurations. The module facilitates I\/O density scaling through internal option slots, while firmware flash compatibility maintains alignment with existing control protocols. This hardware utilizes high-speed internal bus communication to ensure minimal latency in velocity command processing and torque regulation.\u003c\/p\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 20F1AND125JA0NNNNN AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Embedded I\/O terminal block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNote: The unit is supplied as a \"Blank\" configuration without an external Human Interface Module (HIM).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation and Field Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: Mount the Frame 6 chassis vertically in an industrial cabinet, ensuring adequate clearance above and below for the forced-air cooling system operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShielding: Utilize high-frequency shielded cabling for motor leads to minimize radiated electromagnetic interference (EMI).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding: Bond the drive chassis to the plant protective earth bus. Maintain the factory-installed common-mode (CM) jumper to ensure compliance with EMC filtering standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnvironment: Install only within environments free of corrosive gas. Ensure ambient air temperature and humidity remain within defined limits to prevent operational derating.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is this drive model equipped with a dynamic braking transistor?\u003c\/p\u003e\n\u003cp\u003eA: No, the 20F1AND125JA0NNNNN model does not include a dynamic braking (DB) transistor; it is intended for applications without regenerative energy requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Does the drive come with an interface module?\u003c\/p\u003e\n\u003cp\u003eA: No, this model is supplied with a \"Blank\" interface (no HIM), requiring an external HIM or configuration software for programming and monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the maximum motor power rating?\u003c\/p\u003e\n\u003cp\u003eA: The drive is rated for 100 HP in Normal Duty (ND) applications and 75 HP in Heavy Duty (HD) applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Is the unit suitable for outdoor use?\u003c\/p\u003e\n\u003cp\u003eA: No, this is an Open Type (IP20\/IP00) unit and must be enclosed within an appropriate cabinet to prevent ingress of foreign objects and moisture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: What is the function of the CM jumper?\u003c\/p\u003e\n\u003cp\u003eA: The CM jumper provides a reference for the internal EMC filter, which is required for effective common-mode noise suppression on the AC line side.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Can this drive connect to a common DC bus?\u003c\/p\u003e\n\u003cp\u003eA: No, the 20F1AND125JA0NNNNN model lacks DC terminals and is restricted to AC input and precharge configurations only.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: How are firmware updates performed?\u003c\/p\u003e\n\u003cp\u003eA: Firmware is flash-compatible and can be updated via the drive's embedded communication ports using standard configuration software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQ: Are the cooling fans field-serviceable?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the cooling system is designed for service access; refer to the technical manual for replacement part numbers and procedural steps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066467405997,"sku":"20F1AND125JA0NNNNN","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-2_68528e5c-a276-4d5b-9952-5e6a41993685.jpg?v=1782441891","url":"https:\/\/www.maxwellplc.com\/ru\/products\/20f1and125ja0nnnnn-allen-bradley-powerflex-753-ac-drive","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}