{"product_id":"20f1anc477ja0nnnnn-allen-bradley-powerflex-753-variable-frequency-ac-drive","title":"20F1ANC477JA0NNNNN Allen-Bradley PowerFlex 753 Variable Frequency AC Drive","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eConfigured for variable-speed motor control in the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePowerFlex 753\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edrive platform, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F1ANC477JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e20F1ANC477JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive) provides direct electrical execution through embedded I\/O, AC input precharge circuitry, integrated EMC filtering, and dynamic braking capability for three-phase drive systems.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct Configuration\u003c\/h3\u003e\n\u003cp\u003eThe complete catalog number\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e20F1ANC477JA0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003edefines a factory-configured version of the PowerFlex 753 AC Drive. The drive configuration includes voltage class, output capacity, frame size, enclosure style, EMC filtering, cooling method, and dynamic braking hardware. Individual catalog characters should be interpreted only according to official Allen-Bradley catalog documentation.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e20F1ANC477JA0NNNNN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003ePowerFlex 753 AC Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003ePowerFlex 753\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eVariable Frequency AC Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBulletin Number\u003c\/td\u003e\n\u003ctd\u003ePowerFlex 753 AC Drive with Embedded I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Class\u003c\/td\u003e\n\u003ctd\u003e400 VAC, 3 Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Bus Voltage\u003c\/td\u003e\n\u003ctd\u003e540 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e456 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Duty Rating\u003c\/td\u003e\n\u003ctd\u003e250 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeavy Duty Rating\u003c\/td\u003e\n\u003ctd\u003e200 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eForced Air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrosive Gas Protection\u003c\/td\u003e\n\u003ctd\u003eStandard Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrame Size\u003c\/td\u003e\n\u003ctd\u003eFrame 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Configuration\u003c\/td\u003e\n\u003ctd\u003eAC Input with Precharge, No DC Terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Classification\u003c\/td\u003e\n\u003ctd\u003eIP20\/IP00, NEMA\/UL Type Open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMC Filtering\u003c\/td\u003e\n\u003ctd\u003eFiltered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Braking\u003c\/td\u003e\n\u003ctd\u003eIntegrated DB Transistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded I\/O\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Location\u003c\/td\u003e\n\u003ctd\u003eXiamen, China\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShipping Dimensions\u003c\/td\u003e\n\u003ctd\u003e29.5 x 40.5 x 17.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eRefer to manufacturer documentation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDepends on motor load and operating conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTariff Code\u003c\/td\u003e\n\u003ctd\u003e8537101190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFirmware Compatibility and EtherNet\/IP Integration\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 753 platform supports firmware-controlled operation with embedded I\/O and optional industrial communication adapters. Firmware revision compatibility should be verified before replacing an existing drive or restoring archived parameter files. Matching firmware revisions help maintain deterministic communication and parameter consistency throughout the control system.\u003c\/p\u003e\n\u003ch3\u003eOrdering Information\u003c\/h3\u003e\n\u003cp\u003eThe standard shipment typically includes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Allen-Bradley 20F1ANC477JA0NNNNN PowerFlex 753 AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Factory-installed Embedded I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Factory-installed EMC Filter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Integrated Dynamic Braking Transistor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Product Identification Label\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Manufacturer Documentation (when supplied)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOptional accessories may include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHuman Interface Module (HIM)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEtherNet\/IP Communication Adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl I\/O Expansion Modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafe Torque Off Option Modules\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLine Reactors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Reactors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBrake Resistor Assemblies\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCooling Fan Replacement Kits\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\n\u003ch4\u003eMechanical Installation\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstall the drive in the specified vertical orientation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain adequate airflow around the cooling system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstall inside an electrical enclosure suitable for the operating environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrevent conductive dust from entering ventilation openings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePower Wiring\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify supply voltage before energizing the drive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDisconnect all power sources before servicing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the protective earth conductor before startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelect conductors and protective devices according to the application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRoute motor cables separately from signal wiring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eControl Wiring\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSeparate communication cables from power conductors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround cable shields according to the system grounding strategy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify terminal tightness before applying power.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm embedded I\/O assignments during commissioning.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCommissioning\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConfigure motor nameplate data before operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify firmware compatibility with the controller project.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm communication parameters before network startup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInspect wiring and grounding before energizing the equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan the drive be removed while energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Disconnect the incoming power source and allow the DC bus to discharge before servicing the drive.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this model include embedded I\/O?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Embedded I\/O is included as part of the factory configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs a dynamic braking transistor included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. This catalog number includes an integrated dynamic braking transistor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan communication modules be added later?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Optional communication adapters compatible with the PowerFlex 753 platform can be installed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShould firmware versions match when replacing a drive?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Matching firmware revisions improve parameter compatibility and communication consistency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIs EMC filtering included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. The drive is supplied with factory-installed EMC filtering.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan signal cables share the same conduit as motor cables?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eNo. Separate routing helps reduce electromagnetic interference and improves signal quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat should be verified before initial startup?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eVerify firmware revision, supply voltage, grounding, parameter settings, communication configuration, and wiring integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066467307693,"sku":"20F1ANC477JA0NNNNN","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-1_5f9914e9-3df3-482d-85c2-726b334bf5b1.jpg?v=1782441946","url":"https:\/\/www.maxwellplc.com\/ru\/products\/20f1anc477ja0nnnnn-allen-bradley-powerflex-753-variable-frequency-ac-drive","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}