{"product_id":"20f1anc302jn0nnnnn-allen-bradley-ac-drive-powerflex-753","title":"20F1ANC302JN0NNNNN Allen-Bradley AC Drive PowerFlex 753","description":"\u003cp\u003eConfigured for variable frequency motor speed regulation in EtherNet\/IP deterministic networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F1ANC302JN0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003ePowerFlex 753\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eEngineering Parameter Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F1ANC302JN0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 x 40.5 x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e160 kW ND \/ 132 kW HD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 VAC, 3 PH \/ 540 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e302 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eOpen Type (IP20\/IP00, NEMA\/UL Type Open)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAC Input with Precharge, no DC Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrame Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFrame 7\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEMC Filtering\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFiltered, CM jumper installed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDynamic Braking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNone\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Architecture \u0026amp; Platform Integration\u003c\/h3\u003e\n\u003cp\u003eThis Frame 7 drive architecture executes synchronized operational loops over EtherNet\/IP deterministic networks via optional communication adapters. Embedded I\/O channels route raw signals directly into the processing core, eliminating external network propagation delays. Firmware flash compatibility enables synchronization with Logix control platforms, maintaining uniform instruction execution across multi-axis topologies while native control algorithms maintain tight loop regulation under variable loads.\u003c\/p\u003e\n\u003ch3\u003eStandard Procurement Fulfillment\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Allen-Bradley 20F1ANC302JN0NNNNN AC Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Factory Calibration and Hardware Verification Report\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Frame 7 Mechanical Reference Manual\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOn-Site Deployment Requirements\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Orientation Constraints\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSecure the chassis exclusively in a vertical orientation on a rigid, vibration-resistant backpanel to prevent uneven stress on power internal buses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eThermal Boundary Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaintain an open perimeter of 150 mm on both top and bottom faces of the Frame 7 enclosure to avoid thermal restriction of the forced air fan paths.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEMI Ground Shielding Termination\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBond motor cable shields directly to the drive ground bus with a low-impedance connection to prevent high-frequency common-mode noise propagation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Screw Fastening Metrics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eApply the exact manufacturer-rated nominal torque to all AC power input and output terminal blocks to mitigate localized heat build-up.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDrive Hardware Operations FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat specific function does the pre-installed CM jumper perform on this unit?\u003c\/p\u003e\n\u003cp\u003eThe CM jumper ties internal EMI filtering capacitors directly to chassis ground to provide common-mode noise suppression on symmetrical electrical systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan option cards or internal communication modules be hot-swapped during active operations?\u003c\/p\u003e\n\u003cp\u003eNo. Option modules do not support hot-swap maneuvers. Complete isolation of input lines and total bus voltage discharge are required before card extraction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the control firmware handle main logic updates and flash cycles?\u003c\/p\u003e\n\u003cp\u003eFirmware flash compatibility allows updates via specialized software tools, requiring the drive control loop to be inhibited during the rewrite process.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the electrical consequence of the \"no DC Terminals\" physical configuration?\u003c\/p\u003e\n\u003cp\u003eThis configuration prevents direct connection to a shared DC bus network, restricting the unit to localized AC power distribution configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this specific version support dynamic braking resistors directly?\u003c\/p\u003e\n\u003cp\u003eNo. This drive configuration does not incorporate an internal dynamic braking chopper circuit; external braking modules must be introduced.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat mechanism provides cooling for the power semiconductor modules?\u003c\/p\u003e\n\u003cp\u003eThe unit utilizes an internal forced air fan assembly that routes ambient air through the main rear-mounted aluminum heat sink fins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs an external precharge bypass contactor required for line start?\u003c\/p\u003e\n\u003cp\u003eNo. The drive contains internal precharge circuitry linked with the AC input terminals to control current spikes when line power is applied.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat indicates that the DC bus capacitors are safe for terminal interaction?\u003c\/p\u003e\n\u003cp\u003eAn onboard LED indicator must extinguish completely, and physical verification with a multimeter must register 0 VDC across internal test points.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066466980013,"sku":"20F1ANC302JN0NNNNN","price":119.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-1_49dbc8ab-486e-4171-9bc0-dbb124a700b8.jpg?v=1782442273","url":"https:\/\/www.maxwellplc.com\/ru\/products\/20f1anc302jn0nnnnn-allen-bradley-ac-drive-powerflex-753","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}