{"product_id":"20f1anc170ja0nnnnn-allen-bradley-powerflex-753-ac-drive","title":"20F1ANC170JA0NNNNN Allen-Bradley PowerFlex 753 AC Drive","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F1ANC170JA0NNNNN\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePowerFlex 753\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive, operates as a dedicated hardware component for variable frequency motor speed and torque control within EtherNet\/IP deterministic networks.\u003c\/p\u003e\n\u003ch3\u003eFactory Configuration Statement\u003c\/h3\u003e\n\u003cp\u003eThis unit constitutes an integrated power module assembly specified under catalog code 20F1ANC170JA0NNNNN. In accordance with strict engineering protocols for this hardware designation, the full alphanumeric string designates a pre-configured factory build containing specific options for filtration, cooling, frame size, and voltage class that must be deployed and maintained as a non-divisible technical asset.\u003c\/p\u003e\n\u003ch3\u003eTechnical Parameters\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F1ANC170JA0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 x 40.5 x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e90 kW ND \/ 75 kW HD\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 V AC, 3 Phase \/ 540 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e170 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ IP00, NEMA\/UL Type Open\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrame Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFrame 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDynamic Braking\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDB Transistor Included\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHuman Interface Module\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHIM Blank (No HIM)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eJumper Option\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eM Jumper Installed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe internal processing architecture is designed to sustain continuous communication synchronization over EtherNet\/IP deterministic networks. The drive firmware supports active parameter mapping to control registers without degrading backplane bus communication velocity licenses. This ensures high-speed I\/O density scaling when exchanging torque, velocity, and diagnostic words with Logix-based automation controllers while adhering to established firmware flash compatibility matrices.\u003c\/p\u003e\n\u003ch3\u003ePackage Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Allen-Bradley 20F1ANC170JA0NNNNN PowerFlex 753 Drive\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Factory Installed Internal Jumpers Documentation Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Terminal Connector Block Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Mounting Guidelines\u003c\/h3\u003e\n\u003ch3\u003eMechanical Orientation\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMount the Frame 6 enclosure vertically onto a flat, non-vibrational industrial backpanel layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain all manufacturer-specified free space air gaps around the unit for top-to-bottom forced air flow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Wiring and Grounding\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRoute all three-phase 400 V AC input conductors through separate conduit layout paths away from low-voltage signal wires.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminate low-impedance grounding straps between the drive chassis frame and the central protective earth bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Engineering FAQ\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the ambient temperature threshold for standard operation?\u003c\/p\u003e\n\u003cp\u003eThe hardware maintains operational performance boundaries within a range of 0 to 50 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs hot-swapping option cards permitted while the system is powered?\u003c\/p\u003e\n\u003cp\u003eNo, hot-swap behaviors are strictly unsupported; all primary and control voltages must be disabled first.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the specific power capacities under different load conditions?\u003c\/p\u003e\n\u003cp\u003eThe unit outputs 170 Amps, corresponding to 90 kW Normal Duty or 75 kW Heavy Duty operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat internal configuration options are included for braking performance?\u003c\/p\u003e\n\u003cp\u003eThis model comes configured with an integrated internal DB Transistor, though dynamic braking resistors are separate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of human interface option is integrated into the front chassis?\u003c\/p\u003e\n\u003cp\u003eThis configuration features a HIM Blank cover plate, meaning no integrated Human Interface Module is present.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat physical constraints apply to installation spaces and freight calculation?\u003c\/p\u003e\n\u003cp\u003eThe drive weighs 6 kg and requires a physical outline volume of 29.5 x 40.5 x 17.2 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit process data over the backplane bus?\u003c\/p\u003e\n\u003cp\u003eThe system maintains low-latency parameters for real-time parameter exchange without affecting communication velocity licenses.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat type of line grounding layout is expected with the default configuration?\u003c\/p\u003e\n\u003cp\u003eThe unit features an M jumper installed, modifying internal filter circuitry for optimized performance on matching power systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066466488493,"sku":"20F1ANC170JA0NNNNN","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-3_159144ae-338a-405a-bc0c-411edf1371f1.jpg?v=1782442949","url":"https:\/\/www.maxwellplc.com\/ru\/products\/20f1anc170ja0nnnnn-allen-bradley-powerflex-753-ac-drive","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}