{"product_id":"20f1anc140jn0nnnnn-allen-bradley-ac-drive-powerflex-753","title":"20F1ANC140JN0NNNNN Allen-Bradley AC Drive PowerFlex 753","description":"\u003cp\u003eConfigured for variable frequency motor speed and torque regulation in automated industrial networks, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20F1ANC140JN0NNNNN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003ePowerFlex 753\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAC Drive) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eFactory Configuration Statement\u003c\/h3\u003e\n\u003cp\u003eThis unit constitutes an integrated power module assembly specified under catalog code 20F1ANC140JN0NNNNN. In accordance with strict engineering protocols for this hardware designation, the full alphanumeric string designates a pre-configured factory build containing specific options for filtration, cooling, frame size, and voltage class that must be deployed and maintained as a non-divisible technical asset.\u003c\/p\u003e\n\u003ch3\u003eHardware Parameter Table\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20F1ANC140JN0NNNNN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e29.5 x 40.5 x 17.2 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to 50 deg C (Standard open type rating)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e75 kW ND \/ 55 kW HD (Output capacity reference)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVoltage Class\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400 V AC, 3 Phase \/ 540 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e140 Amps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eEnclosure Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP20 \/ IP00, NEMA\/UL Type Open\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFrame Size\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFrame 6\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eJumper Connection\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDefault CM Jumper Installed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCooling Layout\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eForced Air\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe internal processing architecture is designed to sustain continuous communication synchronization over EtherNet\/IP deterministic networks. The drive firmware supports active parameter mapping to control registers without degrading backplane bus communication velocity licenses. This ensures high-speed I\/O density scaling when exchanging torque, velocity, and diagnostic words with Logix-based automation controllers while adhering to established firmware flash compatibility matrices.\u003c\/p\u003e\n\u003ch3\u003eDelivery Components\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Allen-Bradley 20F1ANC140JN0NNNNN Drive Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Factory Installed Internal Jumpers Documentation Package\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Set of Protective Plugs for Unused Conduit Openings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Protocols\u003c\/h3\u003e\n\u003ch3\u003eMechanical Mounting\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBolt the Frame 6 chassis vertically onto an uninsulated metal subpanel inside a controlled layout.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaintain minimum clearance spaces around the air intakes to prevent thermal current restriction.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePower Termination and Grounding\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eConnect the 400 V AC three-phase supply lines directly to the input terminals utilizing proper torque values.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the drive ground lug connects directly to the central bonded PE bus via low-impedance straps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Queries and Answers\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the thermal operational boundary for this Frame 6 unit?\u003c\/p\u003e\n\u003cp\u003eThe drive operates between 0 and 50 deg C when mounted inside an enclosure providing standard airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the factory common mode connection configured out of the box?\u003c\/p\u003e\n\u003cp\u003eThe hardware is delivered with the CM jumper installed, matching requirements for grounded systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan option cards be inserted while the main AC lines remain active?\u003c\/p\u003e\n\u003cp\u003eNo, hot-swap behavior is not supported; all main line and control power must be completely isolated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the total mass and layout footprint of this physical asset?\u003c\/p\u003e\n\u003cp\u003eThe device scales at a net weight of 6 kg with physical envelope constraints of 29.5 x 40.5 x 17.2 cm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the response latency variation for deterministic control over the option bus?\u003c\/p\u003e\n\u003cp\u003eNetwork updating depends on the master RPI settings, but the internal hardware processes velocity commands within deterministic guidelines.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to the firmware flash profile during an unauthorized power cycle?\u003c\/p\u003e\n\u003cp\u003eA sudden drop in operating voltage during flash storage writes can corrupt non-volatile memory sectors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this configuration provide embedded dynamic braking resistors?\u003c\/p\u003e\n\u003cp\u003eNo, the model features an integrated transistor option denoted as none, requiring external hardware modules if needed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do the output capacities change between regular and severe industrial environments?\u003c\/p\u003e\n\u003cp\u003eThe hardware delivers 140 Amps continuous output, translating to 75 kW Normal Duty or 55 kW Heavy Duty.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066466226349,"sku":"20F1ANC140JN0NNNNN","price":299.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20F1A-1_6c3771a5-0160-4bab-b0f7-79ca7dada52f.jpg?v=1782442661","url":"https:\/\/www.maxwellplc.com\/ru\/products\/20f1anc140jn0nnnnn-allen-bradley-ac-drive-powerflex-753","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}