{"product_id":"20d-dl2-cke1-allen-bradley-powerflex-700s-control-module","title":"20D-DL2-CKE1 Allen-Bradley PowerFlex 700S Control Module","description":"\u003cp\u003eConfigured for integrated drive control and logic execution in PowerFlex 700S platforms, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 20D-DL2-CKE1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003e20D-DL2-CKE1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eControl Module) provides direct physical\/electrical execution for DriveLogix5730 processing tasks.\u003c\/p\u003e\n\u003ch3\u003eModule Configuration \u0026amp; Assembly\u003c\/h3\u003e\n\u003cp\u003eThe 20D-DL2-CKE1 functions as a DriveLogix control upgrade kit designed specifically for the PowerFlex 700S Phase II architecture. This assembly incorporates an expanded cassette interface to house the DriveLogix5730 processor, enabling high-performance local sequence control and data handling within the drive environment.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20D-DL2-CKE1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUSA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.96 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31.5 x 19 x 6.5 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10 deg C to 50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDependent on host drive load\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCore Function\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDriveLogix5730 Integration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Network Communication\u003c\/h3\u003e\n\u003cp\u003eThe PowerFlex 700S platform utilizes high-speed backplane bus communication to maintain deterministic performance across automated control networks. This control module supports firmware flash compatibility, allowing localized updates to drive control algorithms and integrated logic programs. The DriveLogix processor enables I\/O density scaling, ensuring precise synchronization of complex drive-based motion tasks within multi-axis systems.\u003c\/p\u003e\n\u003ch3\u003eOrdering info\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 x 20D-DL2-CKE1 Control Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Expanded cassette housing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 x Technical documentation set\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eElectrostatic Discharge (ESD) Precautions:\u003c\/p\u003e\n\u003cp\u003eUse a grounded wrist strap when handling the module to prevent damage to sensitive internal circuitry on the DriveLogix processor board.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCassette Seating:\u003c\/p\u003e\n\u003cp\u003eEnsure the module is correctly aligned with the host drive backplane pins before applying force to lock the cassette into the drive chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrounding Continuity:\u003c\/p\u003e\n\u003cp\u003eVerify that the module chassis maintains a solid metal-to-metal contact with the host drive frame to ensure appropriate shielding and noise mitigation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCabling Management:\u003c\/p\u003e\n\u003cp\u003eRoute all logic-level I\/O cabling away from high-current power leads to maintain signal integrity for the integrated PLC functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eIs the DriveLogix5730 processor pre-installed?\u003c\/p\u003e\n\u003cp\u003eThis kit is designed to support the DriveLogix5730 integration; verify if the processor card is included in the specific shipping package version.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this module require an external power supply?\u003c\/p\u003e\n\u003cp\u003eNo. The module derives its operating power directly from the host drive's backplane internal power supply.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan firmware be updated through this module?\u003c\/p\u003e\n\u003cp\u003eYes. Firmware updates for both the module and the integrated DriveLogix processor are managed through the drive's primary communication interface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs this compatible with PowerFlex 700 Phase I drives?\u003c\/p\u003e\n\u003cp\u003eNo. This component is specifically engineered for the PowerFlex 700S Phase II control architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens if the module is removed while powered?\u003c\/p\u003e\n\u003cp\u003eRemoving the control module while the drive is energized will result in a communications fault and an immediate cessation of all drive control logic.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the DriveLogix logic programmed?\u003c\/p\u003e\n\u003cp\u003eProgramming is performed via standard industrial automation engineering software compatible with the DriveLogix5730 environment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this kit provide additional I\/O terminals?\u003c\/p\u003e\n\u003cp\u003eThe module enables access to the expanded cassette features, which may include additional I\/O depending on the specific DriveLogix daughter card configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIs the module field-replaceable?\u003c\/p\u003e\n\u003cp\u003eYes, the module is a field-replaceable unit. Always ensure the host drive is fully isolated from mains power before initiating replacement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066461278381,"sku":"20D-DL2-CKE1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/20D-DL2-CKE1_1.jpg?v=1782453475","url":"https:\/\/www.maxwellplc.com\/ru\/products\/20d-dl2-cke1-allen-bradley-powerflex-700s-control-module","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}