{"product_id":"2094-am02-allen-bradley-axis-module-kinetix-6000-series","title":"2094-AM02 Allen-Bradley Axis Module Kinetix 6000 Series","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 2094-AM02\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2094-AM02\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAxis Module, operates as a dedicated hardware component for multi-axis servo drive inverter execution within Kinetix 6000 multi-axis motion control systems. It accepts standard DC-bus power rails from an integrated Power Module and translates this energy via pulse-width modulation into synchronous three-phase output to drive permanent magnet servo motors, managing exact rotor positioning and torque feedback loop processing without integrated safe torque-off physical circuits.\u003c\/p\u003e\n\u003ch3\u003eDesignation Profile and Option Breakdown\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Family prefix: 2094 (Kinetix 6000 Modular Multi-Axis Motion Platform)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModule Identifier: AM (Axis Module \/ Inverter Component)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent \/ Power Rating Matrix: 02 (15 A continuous peak, 3.4 kW capacity rating)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFunctional Safety Subcode: Base variant lacking safe torque-off hardware interfaces\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEngineering Specifications Matrix\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2094-AM02\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAxis Inverter Module\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Bus Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200 \/ 230 VAC equivalent DC bus link\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Rating\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3.4 kW\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eContinuous Current Output\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e15 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFunctional Safety Feature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWithout Safe Torque-Off (STO)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBackplane System Interface\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eKinetix 6000 Shared DC Bus Rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 to +50 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSystem backplane derived logic load plus 3.4 kW inverter throughput\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8504409570\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e7.6 cm x 25.4 cm x 17.8 cm (3.0 in x 10.0 in x 7.0 in)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 lbs (1.6 kg)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Sync Platform and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe unit interfaces directly through specialized high-performance system backplanes to handle data synchronization. The system handles deterministic EtherNet\/IP deterministic networks parameters via standard SERCOS digital links, facilitating immediate firmware flash compatibility updates directly through the host controller network interface. This arrangement coordinates rapid axis-to-axis coordination loops, stabilizing total I\/O density scaling and response velocity across multiple inverter segments without inducing communication blockages or timing latency on the active system backplane.\u003c\/p\u003e\n\u003ch3\u003ePacking List and Standard Contents\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 All-Bradley 2094-AM02 Axis Inverter Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Factory Hardware Identification Sheet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Direct Connection Bus Bar Terminal Block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Installation and Wire Routing Directives\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower Rail Installation Setup\u003c\/p\u003e\n\u003cp\u003eSlide the unit onto the standard 2094 Integrated Multi-Axis Drive Power Rail system. Torque all captive industrial mechanical mounting screws to ensure proper electrical interface with the common DC bus links.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh Voltage Motor Wire Shielding\u003c\/p\u003e\n\u003cp\u003eTerminate all motor power conductors using continuous 360-degree braided copper shield grounding clamps. Route motor power output lines strictly away from low-level feedback encoder cables to eliminate high-frequency cross-talk interference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThermal Vent Clearance Requirements\u003c\/p\u003e\n\u003cp\u003eProvide a minimum structural air boundary clearance above and below the module chassis to ensure natural air draft patterns over internal heatsink plates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this specific axis unit support direct hot-swap extraction while the power rail is energized?\u003c\/p\u003e\n\u003cp\u003eNo, hot-swap operations are strictly prohibited; the common DC bus power must be fully discharged before decoupling the module from its rail assembly.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan this standard inverter drive module execute Safe Torque-Off safety logic profiles?\u003c\/p\u003e\n\u003cp\u003eNo, this component variant is manufactured without safe torque-off functional hardware options and does not execute physical STO interrupts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to internal system parameters if the firmware flash compatibility check detects a mismatch?\u003c\/p\u003e\n\u003cp\u003eThe module will enter a non-operational fault lock condition, requiring a unified firmware image update download from the master controller.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat is the primary physical energy source that drives this hardware component?\u003c\/p\u003e\n\u003cp\u003eThe module draws its functional power from the common shared DC bus structure generated by the primary Kinetix 6000 Integrated Power Module.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat baseline operating temperature limits apply to this specific physical chassis layout?\u003c\/p\u003e\n\u003cp\u003eThe drive inverter is engineered for continuous operations within strict structural temperature bounds from 0 to +50 deg C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is electrical motor grounding controlled inside the mechanical connection block?\u003c\/p\u003e\n\u003cp\u003eA low-impedance copper ground point located inside the terminal housing must interface directly with the factory motor chassis ground lead.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this device feature integrated I\/O density scaling options directly on the front panel board?\u003c\/p\u003e\n\u003cp\u003eNo, standard digital and analog axis control signals are mapped directly through the primary SERCOS optical interface loops.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat action must occur if high-frequency noise interrupts the digital communication line?\u003c\/p\u003e\n\u003cp\u003eVerify the installation of factory fiber-optic cables and inspect the common grounding path continuity between the drive panel and the incoming main line filter.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066460917933,"sku":"2094-AM02","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/2094-AM023.jpg?v=1784020054","url":"https:\/\/www.maxwellplc.com\/ru\/products\/2094-am02-allen-bradley-axis-module-kinetix-6000-series","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}