{"product_id":"2080-l50e-24qbb-allen-bradley-controller-new-original-stock","title":"2080-L50E-24QBB Allen-Bradley Controller | New \u0026 Original Stock","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 2080-L50E-24QBB\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e2080-L50E-24QBB\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProgrammable Control Module, operates as a dedicated hardware component for industrial discrete and analog logic processing within Micro800 Series platforms. The module executes programmed logic loops based on physical inputs, directly managing terminal voltage transitions and routing processed control registers over built-in communication pathways.\u003c\/p\u003e\n\u003ch3\u003eSuffix Nomenclature and Hardware Selection\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e2080: Base product line for the Micro800 modular hardware architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eL50E: Performance class and platform designation within the controller family.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e24QBB: Specific structural hardware mapping (24 I\/O points, 24 VDC power requirement, and transistor output circuitry).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2080-L50E-24QBB\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAllen-Bradley\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUnited States\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModule Type\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProgrammable Controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eControl System Series\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMicro800 (Micro850 \/ Micro870 Architecture)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e12 Inputs, 24 VDC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDigital\/Analog Outputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8 Outputs (7 Relay and 1 Analog 0 - 10 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAnalog Inputs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Analog Inputs (0 - 10 VDC, shared with DC inputs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSystem Terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFixed screw terminals\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 to +65 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNominal 24 VDC input (operational range 20.4 to 26.4 VDC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTariff Code\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e8537101190\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eShipping Dimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e21.2 cm x 5.9 cm x 16.8 cm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2.25 kg (4.96 lbs)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Ethernet Networking and I\/O Synchronization\u003c\/h3\u003e\n\u003cp\u003eThis controller utilizes embedded communication interfaces supporting Profinet \/ EtherNet\/IP deterministic networks to enforce precise signal transport across remote device networks. Real-time backplane bus communication velocity licenses allow the unit to run high-speed calculations without communication bottlenecks. Hardware configurations feature complete firmware flash compatibility, letting field technicians match the firmware state with master network profiles. This maintains fast scan execution rates as the system expands its localized I\/O density scaling.\u003c\/p\u003e\n\u003ch3\u003eShipping Package Manifest\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e1 Allen-Bradley 2080-L50E-24QBB Controller Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Factory Calibration Certificate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 Set of Protective Terminal Barriers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Assembly and Electrical Hookup\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDIN-Rail Mount Attachment\u003c\/p\u003e\n\u003cp\u003eSnap the unit onto standard 35 mm DIN-rail systems. Secure the end anchors tightly to minimize lateral movement in environments with high physical vibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Line Shielding\u003c\/p\u003e\n\u003cp\u003eTerminate all 0 - 10 VDC analog inputs using twisted-pair, shielded cables. Connect the shield at the panel ground bar to suppress high-frequency electrical noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal Block Torque Bounds\u003c\/p\u003e\n\u003cp\u003eTighten the fixed screw terminals using a calibrated screwdriver, keeping within the factory torque limits to prevent damaging the internal board traces.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this specific programmable controller support hot-swapping or active replacement under power?\u003c\/p\u003e\n\u003cp\u003eNo, the fixed terminal design requires a complete power shutdown before modifying or disconnecting any physical wire connections.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCan the analog input channels run parallel circuits with external 4-20 mA current loops?\u003c\/p\u003e\n\u003cp\u003eNo, the analog input channels are designed exclusively for 0 - 10 VDC voltage signals. Current signals require external conversion resistors.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat happens to active outputs if the backplane bus communication velocity is interrupted?\u003c\/p\u003e\n\u003cp\u003eThe controller transitions to its configured fault state, shutting down digital outputs to protect downstream machinery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow is the sharing mechanism between the digital and analog inputs managed internally?\u003c\/p\u003e\n\u003cp\u003eSpecific terminals are multiplexed; configuring them as analog in software overrides and disables their standard 24 VDC digital input register functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDoes this control module require external licensing to enable standard EtherNet\/IP messaging?\u003c\/p\u003e\n\u003cp\u003eNo, the core Ethernet protocol features are enabled out of the box through the factory firmware, requiring no additional licensing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhat are the specific terminal wire stripping requirements for the fixed screw connection blocks?\u003c\/p\u003e\n\u003cp\u003eStrip the conductor insulation back exactly 6 mm before inserting the wire into the screw terminal to prevent exposed copper shorts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow do you update or align the unit's operating system with firmware flash compatibility protocols?\u003c\/p\u003e\n\u003cp\u003eConnect a PC to the controller's integrated communication port and use the factory programming software to upload the certified firmware image.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHow does the unit protect its internal real-time memory registers during a supply power failure?\u003c\/p\u003e\n\u003cp\u003eThe module stores the active program and registers in non-volatile flash memory, retaining system data without requiring a backup battery.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":46066460360877,"sku":"2080-L50E-24QBB","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0733\/1613\/9181\/files\/2080-l50e-24qbb_14.jpg?v=1784021600","url":"https:\/\/www.maxwellplc.com\/ru\/products\/2080-l50e-24qbb-allen-bradley-controller-new-original-stock","provider":"Maxwell PLC Ltd","version":"1.0","type":"link"}